User manual BOSCH KAD 62V40/02 SHORT INSTRUCTIONS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BOSCH KAD 62V40/02. We hope that this BOSCH KAD 62V40/02 user guide will be useful to you.

Lastmanuals help download the user guide BOSCH KAD 62V40/02.


Mode d'emploi BOSCH KAD 62V40/02
Download

You may also download the following manuals related to this product:

   BOSCH KAD 62V40/02 SUPPLEMENT (887 ko)
   BOSCH KAD 62V40/02 INSTALLATION INSTRUCTIONS (3470 ko)

Manual abstract: user guide BOSCH KAD 62V40/02SHORT INSTRUCTIONS

Detailed instructions for use are in the User's Guide.

[. . . ] The ice making sections are designed for use indoors in a controlled environment. The remote compressor packages and condensers are designed to operate outdoors. Each sub-system has limits for power, water and temperature. Operational Limitations: Minimum Air Temp (IMS) Air Temp (CU) Water Temp Water Pressure Voltage (IMS) Voltage (CU) 50oF -20oF. [. . . ] The vapor and condenser by-pass valves are open during the entire harvest cycle. Clean: The inlet water valve opens to fill the reservoir. The Clean indicator light is switched On. A manually initiated rinse flushes the system. 8 9 7 6 5 4 3 2 1 PUSH BUTTON CONTROL SWITCHES INDICATOR LIGHTS: BIN FULL FREEZE HARVEST CLEAN OFF DIAGNOSTIC LIGHTS: WATER REFRIGERATION Controller Lights and Push Buttons September 2003 Page 27 Eclipseä 1300, 1600 Initial Start Up - 1300 and 1600 Pre Start A soak-out period of four hours is optional for this system. If desired, powering the compressor unit for four hours prior to start up allows the crankcase heater to warm up the oil in the compressor. Connect power to the condensing unit and move its toggle switch to Run or On. Connect or reconnect power to the ice making section. Observe the lights on the controller: After a few minutes ice will begin to form on the evaporators. When enough ice has formed to nearly empty the water reservoir, the controller will refill the reservoir. The next time the water level drops that far, the ice is ready for release and the Controller will initiate a Harvest cycle. ·The Freeze light goes out and the Harvest light switches on. opens. ·The vapor inlet valve in the ice making section ·In the CP unit, the condenser by-pass valve opens and the liquid inlet valve closes ·All flash on as the power supply is reconnected. Note: Because the condensing unit is external to the ice making section, no visible signs of operation will be noticeable until the water begins to cool and frost forms on the evaporator tubing. Go to the condensing unit and confirm that the compressor and fan motor are operating. Warm air will be discharged from the condenser. ·The Water pump will begin to circulate water September 2003 Page 28 Eclipseä 1300, 1600 Purge Adjustment Adjustments Note: While the amount of water purge is adjustable, only those installations with a water supply known to be excellent (very low TDS) should adjust to the minimum setting. See below for purge adjustment instructions. How to Adjust the Amount of Water Purge Adjustment is done by use of the control buttons on the AutoIQ Controller. Examine the next section to become familiar with the AutoIQ Controller before beginning. If the machine is on, push and hold the OFF button for more than 3 seconds, then release it. Push and hold the OFF button for more than 3 seconds (just until all lights flash on) then release it. They should have all flashed once, then certain ones will have turned on to indicate which purge level the machine is set at. There are 5 levels of purge available: Cube Size: Cube size is fixed and cannot be adjusted. Thermostatic Expansion Valve: The TXV is not adjustable, do not attempt to adjust it. [. . . ] Recover refrigerant, repair leak, replace drier, evacuate to 300 microns and weigh in the nameplate charge. Check harness Whistling noise at CP unit during By pass and liquid inlet valve coils not harvest getting power September 2003 Page 42 Eclipseä 1300, 1600 Controller Features & Last Error Recall Last Error/Diagnostic Light Recall To recall the last error on the blue housing CM controller: 3 Program ID The blue housing controller will display a code at power up that indicates which ice machine model it has been programmed for. The code is based on the green lights that are displayed. At power up all lights flash ON once to indicate that the controller has passed its internal self-checks. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BOSCH KAD 62V40/02

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BOSCH KAD 62V40/02 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag