Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BOSCH SMI 63M56EU/74. We hope that this BOSCH SMI 63M56EU/74 user guide will be useful to you.
Lastmanuals help download the user guide BOSCH SMI 63M56EU/74.
Manual abstract: user guide BOSCH SMI 63M56EU/74SUPPLEMENT
Detailed instructions for use are in the User's Guide.
[. . . ] SAVE THIS MANUAL
· Warranty · Installation · How It Works · Care Of · Specifications · Repair Parts
System Tested and Certified by NSF International against NSF/ANSI Standard 42 and 58. See perfomance data sheet for details.
Sears, Roebuck and Co. , 3333 Beverly Road, Hoffman Estates, IL 60179 USA
PRINTED IN U. S. A.
www. KenmoreWater. com
Part No. 7288057 (Rev. E 10/27/06)
Warranty
ONE YEAR FULL WARRANTY ON REVERSE OSMOSIS SYSTEM
When installed, operated and maintained according to all instructions supplied with the product, if this Reverse Osmosis System fails due to a defect in material or workmanship within one year from the date of purchase, call 1-800-4-MY-HOME to arrange for free repair (or replacement if repair proves impossible). This warranty does not include filter cartridges or the Reverse Osmosis membrane, which are expendable items. [. . . ] A common mistake is to stop pushing when the tube engages the o-ring. When a 1/4" tube is fully engaged, 11/16" of the tube has entered the fitting. When a 3/8" tube is fully engaged, 3/4" of the tube has entered the fitting. If using tubing other than tubing supplied with the system, be sure it is of high quality, exact size and roundness with a smooth surface. Push the collet inward with a finger tip. Continue holding collet inward while pulling the tubing out. See Figure 20.
Push In Fitting Tube
Cut tubing square with end of tubing round, smooth, with no cuts, nicks or flat spots.
Tube Correctly Cut
Figure 16
O-Ring Collet
Tube Partially Engaged With Fitting
Figure 17
O-Ring Collet
Tube Fully Engaged With Fitting
Figure 18
Collet (Depress to Remove Tubing) Fitting O-Ring Seal Collet
Tubing
Collet and O-Ring
Disconnect Tubing
Figure 20
Figure 19
Questions?Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater. com
14
Step 6 - Connect Tubes
NOTE: Tubing lengths should allow for the removal of the assembly from the hanger washers for servicing. If tubing lengths are shortened for neater appearance, it may be necessary to keep the assembly on the hanger washers for service. NOTE: Codes in the state of Massachusetts require installation by a licensed plumber and do not permit the use of saddle valves. If you live in the state of Massachusetts, review plumbing code 248-CMR of the Commonwealth of Massachusetts before proceeding with the installation.
"b lu
water supply fitting
1/4"
tu 1/4" green
3/8" black tubing
3/8
red
HOT
COLD
et
ub
in
n tubi
g
sink p-trap
g
3/8" yellow tubing tubing connector
bing
NOTE: Tube colors match Collet colors
Tube Connections
Figure 21 CONNECT YELLOW TUBE TO STORAGE TANK
1. NOTE: The bleach must be removed from the system before drinking the water. See purging instructions on the next page.
Figure 22
Questions?Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater. com
16
Step 7 - Sanitize, Test and Purge System
PRESSURE TEST THE SYSTEM
NOTE: Complete the sanitizing procedures on the preceding page before pressure testing. To pressure test the system, complete the following steps. Open the water supply valve to the Reverse Osmosis System. Open the main water supply valve and several house faucets. This will purge air from the house plumbing and system. Pressure will start to build in the RO system in about 2 hours Carefully check all fittings and connections as the system builds pressure. If problems exist, refer to the troubleshooting chart or call the toll free number. NOTE: When the system is first pressurized, water may ''spurt'' from the faucet air gap hole until air is expelled from the RO system. Please review the following operating features before using your Reverse Osmosis System: You will not have filtered water immediately. [. . . ] Correction: Open Reverse Osmosis faucet and drain tank until flow slows to a drip. Keep faucet open and check tank pressure. Close faucet to refill the tank.
Problem: High total dissolved solids (TDS) in product water
Cause: Water supply to the Reverse Osmosis sys- Correction: tem not within specifications. Correction: Increase water pressure, precondition the water, etc. , as needed to conform before doing maintenance on the Reverse Osmosis system. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BOSCH SMI 63M56EU/74
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BOSCH SMI 63M56EU/74 will begin.