Manual abstract: user guide BOSCH SMU53M75EU/61SUPPLEMENT
Detailed instructions for use are in the User's Guide.
[. . . ] SAVE THIS MANUAL
· Warranty · Installation · How It Works · Care Of · Specifications · Repair Parts
System Tested and Certified by NSF International against NSF/ANSI Standard 42 and 58. See perfomance data sheet for details.
Sears, Roebuck and Co. , 3333 Beverly Road, Hoffman Estates, IL 60179 USA
PRINTED IN U. S. A.
www. KenmoreWater. com
Part No. 7287946 (Rev. E 10/27/06)
Warranty
ONE YEAR FULL WARRANTY ON REVERSE OSMOSIS SYSTEM
When installed, operated and maintained according to all instructions supplied with the product, if this Reverse Osmosis System fails due to a defect in material or workmanship within one year from the date of purchase, call 1-800-4-MY-HOME to arrange for free repair (or replacement if repair proves impossible). This warranty does not include filter cartridges or the Reverse Osmosis membrane, which are expendable items. [. . . ] If using tubing other than tubing supplied with the system, be sure it is of high quality, exact size and roundness with a smooth surface. Push the collet inward with a finger tip. Continue holding collet inward while pulling the tubing out. See Figure 20.
Push In Fitting Tube
Cut tubing square with end of tubing round, smooth, with no cuts, nicks or flat spots.
Tube Correctly Cut
Figure 16
O-Ring Collet
Tube Partially Engaged With Fitting
Figure 17
O-Ring Collet
Tube Fully Engaged With Fitting
Figure 18
Collet (Depress to Remove Tubing) Fitting O-Ring Seal Collet
Tubing
Collet and O-Ring
Disconnect Tubing
Figure 20
Figure 19
Questions?Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater. com
14
Step 6 - Connect Tubes
3/8" black tubing
1/4" red tubing water supply fitting 3/8" blue tubing
NOTE: Tubing lengths should allow access to the back of the assembly for servicing. NOTE: Codes in the state of Massachusetts require installation by a licensed plumber and do not permit the use of saddle valves. If you live in the state of Massachusetts, review plumbing code 248-CMR of the Commonwealth of Massachusetts before proceeding with the installation.
HOT
COLD
sink p-trap
1/4" green tubing
3/8" yellow tubing
tubing connector
Tube Connections
Figure 21 CONNECT YELLOW TUBE TO STORAGE TANK
1. One end is attached to the Reverse Osmosis filter assembly. Run the other end of the yellow tube to the fitting on top of the storage tank. This will occur in the sanitizing step.
CONNECT BLUE TUBE TO REVERSE OSMOSIS ASSEMBLY
The blue tube connection was completed in the faucet assembly steps.
CONNECT BLACK TUBE FROM REVERSE OSMOSIS FAUCET TO DRAIN ADAPTER
1. Locate the 30" length of 3/8" black tube. Pressure will start to build in the RO system in about 2 hours Carefully check all fittings and connections as the system builds pressure. If problems exist, refer to the troubleshooting chart or call the toll free number. NOTE: When the system is first pressurized, water may ''spurt'' from the faucet air gap hole until air is expelled from the RO system. Please review the following operating features before using your Reverse Osmosis System: You will not have filtered water immediately. It may take 1-3 hours to completely fill the storage tank and create maximum flow from the Reverse Osmosis faucet. Water Pressure from the Reverse Osmosis faucet will be less than your standard faucet due to the high level of filtration performed by the system. Water will run to the drain while the Reverse Osmosis system is producing purified water, even if you are not drawing water from the Reverse Osmosis faucet. You may hear a small quantity of water going to the drain for a couple of hours. Water going to the drain will automatically shut off when the storage tank is full. PURGING THE SYSTEM To purge the system, complete the following steps. Open the Reverse Osmosis Faucet and let water through the system for a 24 hour period. [. . . ] See page 20.
Problem: System makes lower amount of product water than usual.
Cause: Storage tank air-charge less than 5-7 psi. Correction: Open Reverse Osmosis faucet and drain tank until flow slows to a drip. Keep faucet open and check tank pressure. Close faucet to refill the tank.
Problem: High total dissolved solids (TDS) in product water
Cause: Water supply to the Reverse Osmosis sys- Correction: tem not within specifications. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BOSCH SMU53M75EU/61
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BOSCH SMU53M75EU/61 will begin.