User manual BOWENS ESPRIT DIGITAL DX250

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BOWENS ESPRIT DIGITAL DX250. We hope that this BOWENS ESPRIT DIGITAL DX250 user guide will be useful to you.

Lastmanuals help download the user guide BOWENS ESPRIT DIGITAL DX250.


Mode d'emploi BOWENS ESPRIT DIGITAL DX250
Download
Manual abstract: user guide BOWENS ESPRIT DIGITAL DX250

Detailed instructions for use are in the User's Guide.

[. . . ] 5600K (UV coated) Full to 1/32 5 f-stop in 1/10 increments 250W 120V Halostar 275W 120V Photoflood UV-Coated L =450mm W=170mm H =125mm 4. 4Kg BW-1024/B BW-1079 Weight Due to our policy of constant product improvement Bowens International Limited reserve the right to change equipment specifications without notice. ACCESSORIES For details of all related products please contact your local distributor. Function Display Controls Lamp Function Control Ready LED Test / Open Flash Figure 2 2 15 Esprit Digital Operating Instructions WARNINGS & FAULT FINDING If the unit appears to have developed a fault, first establish that it is a genuine internal fault and not a case of normal operation such as overheat. Carry out the following checks to eliminate any external causes. If no obvious problem can be found and replacement of the modelling lamp, flash tube or fuse does not effect a cure then it is likely that an internal fault has developed. [. . . ] The Esprit Digital 1000DX is fitted with a cooling fan and will cool faster if left switched on. The unit is equipped with overheat protection, not to limit performance but to prevent damage under abnormal operating conditions. Repeated operation of the overheat protection should be avoided by decreasing the flash power or repetition rate. Dimming or turning the modelling lamp off will help prevent overheating. Whenever possible, avoid rapid high power flashing when using restrictive reflectors such as a snoot or grid reflector, particularly if the unit is pointing downwards. The table below shows maximum number of flashes permissible at various flash rates and flash settings before allowing the unit to cool. This cannot cover all combinations but should be used as a guide to determine the maximum flash rate to meet your requirements. AC Supply The unit operates from an AC Line voltage within the range 95V to 130V with a nominal frequency of either 50Hz or 60Hz. Ensure that the Power ON/OFF switch on the unit is set to OFF. Use a cable supplied by your Bowens dealer to connect to the AC supply. A 3-wire, earthed (grounded), supply system must be used to ensure safe and reliable operation of the unit. Triggering System The Esprit Digital can be triggered by any of the following methods: · TEST/OPEN FLASH RELEASE Button For testing or multiple flash applications the TEST button can be used. The unit will only flash if the unit is charged and the `READY' LED is either lit or flashing. · EXTERNAL SYNCHRONISATION Socket The standard ¼" jack-type socket on the rear panel may be used for direct connection to a camera set to "X" synchronisation. When these are first selected the appropriate display will be automatically selected for checking or adjustment. If the `FUNCTION' or `UP'/'DOWN' buttons are not pressed within 4 seconds then the controls and display will automatically return to the default `FLASH' function. Use the `FUNCTION' button to reselect if required. Functions likely to require less frequent adjustment are accessible via an `OPTIONS' sub-menu. This allows the user to customise certain functions without complicating the main controls. INTERMITTENT Option The preferred mode for the `INTERMITTENT' function can be selected from the `OPTIONS' submenu as follows: Option Description NORMAL. Only available when the LAMP is switched ON (PROP, IND or 100%). The Modelling Lamp will extinguish while the unit recharges and light again when the unit reaches `READY'. If the unit fails to flash for any reason then the LAMP will not be extinguished. Available with the LAMP either ON or OFF. When the unit reaches `READY', after being flashed, the Modelling Lamp will intensify to full brightness and then dim before returning to the previous setting (or to OFF). The exact effect will depend on the current lamp setting. [. . . ] Switch the Infrared Remote Receiver on or off using the `REMOTE' button. IR Remote Control is enabled when the associated LED is lit. `C' - REMOTE CONTROL CHANNEL Display Mode When the IR Remote is switched on the unit will automatically enter the `CHANNEL' display mode to allow adjustment. The `C' before the displayed value indicates this mode: Display Range X Description Display IR Channel number. Use `UP' or `DOWN' to select. INTERMITTENT Button This feature uses the Modelling Lamp to indicate that the unit has flashed correctly and recharged to `READY', it is in addition to the normal indication. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BOWENS ESPRIT DIGITAL DX250

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BOWENS ESPRIT DIGITAL DX250 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag