If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BOWENS STUDIOLITE DMX. We hope that this BOWENS STUDIOLITE DMX user guide will be useful to you.
Lastmanuals help download the user guide BOWENS STUDIOLITE DMX.
Manual abstract: user guide BOWENS STUDIOLITE DMXBROCHURE
Detailed instructions for use are in the User's Guide.
[. . . ] STUDIOLITE INSTRUCTIONS BWL-0377/2 (07/07) BOWENS INTERNATIONAL LIMITED
355 Old Road Clacton on Sea Essex CO15 3RH UK Tel: Fax: +44 (0)1255 422807 +44 (0)1255 436342
www. bowens. co. uk
OPERATING INSTRUCTIONS
Table of Contents
Dear Valued Customer,
Introduction
Description
Page
Introduction & Safety Notes General Features Reflector Care Lamp Installation Studiolite DMX Control Panel Studiolite (analogue) Control Panel Studiolite (analogue) Operation Studiolite DMX Functions Studiolite Accessories Lamp Sets Studiolite Accessories Part Codes How to Assemble. . . (accessories) Studiolite DMX Specifications Studiolite (analogue) Specifications
3 4 4 4 5 6 6 7 - 17 18 - 20 20 21 22 - 30 31 31
Thank you for choosing the Bowens StudioLite DMX professional video lighting system. Accurate, ergonomic, powerful and simple to use, the StudioLite DMX was designed by working closely with videographers to develop a system that meets the standards demanded in professional studios today. For details of all related products, please contact your local distributor, a list of which can be found at www. bowens. co. uk. In order to obtain the full benefit from your purchase, please take a few moments to familiarise yourself with this user manual. [. . . ] The ballast levels can be set from between 0 (min) and 255 (max).
Step 1). From the Base Menu press SELECT to display the asterisk (*).
8 www. bowens. co. uk
www. bowens. co. uk 9
Studiolite DMX Functions
Studiolite DMX Functions
Step 2). With the asterisk (*) next to the Mode: Manual option pressing the SELECT button again then enters the chosen mode (manual) and displays the available functions.
Step 7). When the required option (Set Ballast Level) is selected the user can then use the arrow (up/down) buttons to adjust that particular function to the required setting.
Step 3). By using the arrow (up/down) buttons on the rear of the DMX unit the user can move through the available functions until asterisk (*) is next to the required function (Set Ballast Levels).
Step 8). Once the user has adjusted the chosen function to the desired setting by pressing the DONE button the user can then select that setting; this is confirmed by the arrow (>) changing back into an asterisk (*) allowing the user then to continue changing any further settings. By repeatedly pressing the DONE button the user can navigate back to the top/base menu level.
Step 4). When the asterisk is next to the required function (Set Ballast Level), pressing the SELECT button again then enters the SET BALLAST LEVEL menu. When in the SET BALLAST LEVEL menu the user is given two options, BALLAST NO (which refers to which ballast (top or bottom / 1 or 2) is to be adjusted) and BALLAST LEVEL (which is to control the light output from the lamps).
Ballast Number To Be Adjusted (1 or 2). This option is to choose which ballast (top or bottom / 1 or 2) is to be adjusted (note: if number of dimmable channels is set to 1 then this option is non-applicable).
Step 1). From the Base Menu press SELECT to display the asterisk (*). Step 5) When in the SET BALLAST LEVEL menu the arrow (up/down) buttons can be used to select which option (Ballast Level) is be adjusted.
Step 6). Once the asterisk is positioned next the the required option, pressing the SELECT button changes the asterisk (*) into an arrow (>) which then allows the user to adjust the ballast levels using the arrow (up/down) buttons.
Step 2). With the asterisk (*) next to the Mode: Manual option pressing the SELECT button again then enters the chosen mode (manual) and displays the available functions.
10 www. bowens. co. uk
www. bowens. co. uk 11
Studiolite DMX Functions
Studiolite DMX Functions
Mode Setting (Manual or Remote). Once in the manual mode, the user can scroll through the available options to the desired function (Set Ballast Levels) by using the arrow (up/down) buttons. This option is so the user can choose whether the unit they will be working with is to be used manually or by remote operation (via a DMX control system).
Step 1). From the Base Menu press SELECT to display the asterisk (*). Once the user has navigated to the desired function (Set Ballast Levels) by pressing the SELECT button again the user can enter the next menu level to the available options for the Set Ballast Levels function. Once the asterisk is displayed on the base menu pressing the SELECT button again then allows the user to enter the next menu level to choose which function is to be altered within that mode.
Step 5). To change/select which ballast number is to be adjusted press SELECT when the asterisk (*) is next to the BALLAST NO option to change the asterisk to an arrow (>) which will then allow the user to change that function by using the arrow (up/down) buttons.
Step 6). Once the desired setting is displayed pressing the DONE button then selects that setting and confirms the users selection by changing the arrow (>) back to an asterisk (*) then allowing the user to continue changing any further settings.
Step 3). When the asterisk is next to the mode option pressing the SELECT button then highlights that function by changing the asterisk (*) into an arrow (>) allowing the user to change that option to the required setting.
set ballast levels * ballast no :2 ballast level :50
Step 4). [. . . ] For both the Studiolite DMX455 and the DMX855. The Side Barn Doors must be used with the Top & Bottom Barn doors, simply attach these highly efficient reflectors to maximize the available light to create a remarkably even light spread. Adjustable for more precision controlled light. DMX455: BW4451 DMX855: BW4452 Part Code BW4440 BW4441 BW4442 BW4443 Fabric Diffuser. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BOWENS STUDIOLITE DMX
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.