User manual BURG WACHTER TSE 5002

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BURG WACHTER TSE 5002. We hope that this BURG WACHTER TSE 5002 user guide will be useful to you.

Lastmanuals help download the user guide BURG WACHTER TSE 5002.


Mode d'emploi BURG WACHTER TSE 5002
Download
Manual abstract: user guide BURG WACHTER TSE 5002

Detailed instructions for use are in the User's Guide.

[. . . ] As an option, also the radio controlled key TSE 5103 E-Key can be used. TSE 5001 PINCODE functions (as standard) ­ Total number of users: up to 48 ­ To each pincode user (except administrator) also an E-Key can be assigned. Optional locking media ­ Radio controlled key TSE 5103 E-KEY Time functions ­ User timer (up to 24 different time windows) * ­ Permanent timer (up to 16 different time windows) * * (only together with an appropriate TSE software) History function ­ Storing of last 600 events (readout by optional TSE software) Administrator code ­ Factory set to 1-2-3-4-5-6 (please be sure to modify) Power supply ­ 4 × MIGNON LR6 AA ALKALINE Optical signaling Optical signaling in the form of a LED is incorporated in the knob on the inner side of the door. This LED informs you on the following: ­ 1 × brief: lock has been opened ­ 2 × brief: lock has been shut ­ every 5 sec. [. . . ] Now you can use the keys 1 or 2 to scroll until the user, whose user code should be changed, is displayed ­ Confirm with ON/Enter ­ Enter the so far valid (previous) code and press ON/Enter ­ Enter the new code confirm it with ON/Enter ­ Repeat your entry and confirm it again with ON/Enter. ­ ­ ­ ­ ­ ­ Activate the keypad using the ON/Enter key Then press Function. "Menu/Code change" is displayed Scroll using the 2 key till reaching the appropriate menu item Confirm it with ON/Enter Scroll using the keys 1 or 2 until the required language is displayed Confirm it with ON/Enter ­ ­ ­ ­ ­ Activate the keypad using the ON/Enter key Then press Function. " is displayed Scroll using the 2 key till reaching the appropriate menu item. Confirm it with ON/Enter You can now use the scroll function to choose the following submenus: Submenu user create ­ Confirm it with ON/Enter. Now you can choose between entering a user code, programming an E-Key or saving a fingerscan (fingerscan only for TSE 5002 or with keypad TSE 6102 FS) or programming a transponder (only available for series TSE 6000). ­ Scroll till reaching the appropriate function and confirm it with ON/Enter · Create code ­ Enter the administrator code in order to acquire the authorization for programming ­ The next free memory cell is indicated (e. 0003) ­ Enter the 6 digit code and confirm it 2 × with ON/Enter ­ "Data are stored" is displayed · Create E-Key ­ Enter the administrator code in order to acquire the authorization for programming ­ The next free memory cell is indicated (e. 003), press ON/Enter ­ Bring the E-Key into the programming mode (see the E-Key manual) ­ Then confirm 2 × with ON/Enter ­ "Data are stored" is displayed · Create Fingerscan (fingerscan only for TSE 5002 or with keypad TSE 6102 FS) ­ Enter the administrator code in order to acquire the authorization for programming ­ "Teach-in finger" is displayed ­ Move the finger to be registered 5 × straight over the sensor (the number of these actions is counted on the display) ­ "User_XXX_FP created" is displayed · Create Transponder The function is available only for series TSE 6000 System. Submenu E-Key assign Using this function, you can subsequently assign an E-Key to an already existing user. For this purpose, proceed as follows: ­ Enter the administrator code in order to acquire the authorization for programming ­ Scroll till reaching the user, to whom you intend to assign an E-Key, and confirm 2 × with ON/Enter ­ Bring the E-Key into the programming mode (see the E-Key manual) ­ Once the E-Key is in the programming mode, confirm on the keypad with ON/Enter ­ "Data has been saved" is displayed Submenu delete Using this menu, you can delete a user. ­ Scroll till reaching the appropriate menu and confirm it with ON/Enter ­ Enter your administrator code ­ Scroll till reaching the user or the ident medium (E-Key) you intend to delete and confirm your selection 2 × with ON/Enter ­ "Data record is deleted" is displayed Submenu Timer functions This is intended for setting the time and date · Time entry: ­ Select the function with ON/Enter ­ Enter the hour (2 digits), confirm with ON/Enter ­ Enter the minutes (2 digits), confirm with ON/Enter ­ Data has been saved · Date entry: ­ Select the function with ON/Enter ­ Enter the day (2 digits), confirm with ON/Enter ­ Enter the month (2 digits), confirm with ON/Enter ­ Enter the year (2 digits), confirm with ON/Enter ­ Data has been saved Submenu TSE-Setup General system settings · RFID channel The radio channel can be set up here (12 channels to select from). This can be required when the radio channel is already used by another application, e. WLAN, which can possibly lead to interference. In such case, please select another channel with a spacing of at least 3 channels. Priority In case the door cannot be opened after several attempts with the E-Key, the priority of the door can be increased by this function. Conversely, it can be advisable in such a case to reduce the priority of doors in a direct vicinity. Restructure The use of this function is recommended when several users have been deleted. Install keyboard After a replacement of the cylinder or the keypad, the two units have to be newly aligned, so that they can resume communication. Registration of a keypad ­ Activate the keypad using the ON/Enter key ­ Then press Function. "Menu/Code change" is displayed ­ Then use the keys 1 or 2 to scroll till reaching the Administrator menu ­ Confirm with ON/Enter ­ Use the keys 1 or 2 to scroll till reaching the Admin. Setup TSE setup menu ­ Confirm with ON/Enter ­ Use the keys 1 or 2 to scroll till reaching the Admin. [. . . ] Please read this Assembly Manual carefully before the assembly and then store it at a safe place. The cylinder is provided with a special detent system offering you a possibility to use the cylinder for doors up to a thickness of 120 mm (60/60 mm, measured at the cylinder fixing screw). The fixing of the rotary knobs is provided with an incorporated locking screw in each knob. 3 Depending on the door thickness, you can affix an appropriate adapter on the outer side, in order to improve the path for the emergency key. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BURG WACHTER TSE 5002

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BURG WACHTER TSE 5002 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag