User manual CAMCO D-POWER 2
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CAMCO D-POWER 2. We hope that this CAMCO D-POWER 2 user guide will be useful to you.
Lastmanuals help download the user guide CAMCO D-POWER 2.
Manual abstract: user guide CAMCO D-POWER 2
Detailed instructions for use are in the User's Guide.
[. . . ] D-POWER
SERIES
D-POWER SERIES USER MANUAL
INFORMATION FOR USE FOR MODELS D-POWER 2, D-POWER 3 and D-POWER 4 DUM_GB_200-R2_09-200
© Copyright 200 by CAMCO Produktions- und Vertriebs-GmbH
für Beschallungs- und Beleuchtungsanlagen Fischpicke 5, D-57482 Wenden, Germany Telephone +49 (0) 2762 408-0
D-POWER
SERIES
P.
USER MANUAL D - P O W E R SERIES
D-POWER
SERIES
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
) Read the information for use (user manual). 2) Please keep this user manual in a safe place during the lifetime of the amplifier. The user manual forms an integral part of the amplifier. [. . . ] When the amplifier is switched on again, the selected mode will operate.
3. 6. Stereo Operation, Two Channel Operation Two fully independent amplifier channels (normal operating mode).
D-POWER
A
Z *Zmin
B
Z *Zmin
3. 6. 2 Parallel-Mono Operation Parallel operation of the two channels together.
D-POWER
Zres 0. 5 *Zmin
A
The output terminals of the two channels are configured in parallel using an internal relay. The (single) load is connected either to the output of channel A or to that of channel B (as if in stereo). While the total output of the amplifier remains the same and the output voltage level is also the same as in stereo operation, the minimum impedance that can be connected is reduced by half due to the fact that current capability is doubled. The channel B-Input is inactive turn the volume of channel B down to zero. This mode is useful when, for example, three identical loudspeakers are to be operated with the same power.
P. 3
USER MANUAL D - P O W E R SERIES
D-POWER
SERIES
3 INSTALLATION
3. 6. 3 Mono-Bridge Operation One-channel mono bridged operation.
D-POWER
3. 7 Wiring 3. 7. XLR Connection XLR: Pin = Ground (or lifted via 5 resistor) (See 3. 5 Ground Lift) Pin 2 = Hot (inphase) Pin 3 = Cold (out of phase) Always use symmetrical (balanced) shielded cable to connect the amplifier.
Z 2 *Zmin
Input Channel B Input Channel A LINK B LINK A
A
The second amplifier channel processes the same input signal, but with reversed phase. The (single) load is connected between the two positive channel outputs using a suitable connected SPEAKON connector. While the total output of the amplifier remains the same, both the available output voltage and the minimum impedance that can be connected are doubled, as compared with stereo operation. A signal feeding channel B will have no effect on the output. Turn the volume of channel B down to zero. In Mono-Bridge mode RMS output voltages are as high as 230 V. Wiring to the speaker loads must conform to NEC Class 3 safety standards or its equivalent that meets all national and local electric codes. All customer specific cables may only be manufactured by qualified suppliers/personnel. All cabling or rewiring work must be carried out by qualified personnel. * Zmin = 4 for D-POWER 2, 3 and 4
2 3
2 3
3
2
3
2
To Channel B
To Channel A
Input Ground Lift
Input Ground Lift in position: grounded
ALWAYS SWITCH OFF THE AMPLIFIER BEFORE CHANGING MODES
P. 4
USER MANUAL D - P O W E R SERIES
D-POWER
SERIES
3 INSTALLATION
3. 7. 2 SPEAKON Connection Both SPEAKON connectors are connected to channel A and channel B outputs. The pin configuration of the SPEAKON connectors is as follows: SPEAKON right: Pin + (View at the back) Pin Pin 2+ Pin 2SPEAKON left:
(View at the back)
WARNING !SPEAKON connectors marked with the lightning flash indicate high voltages that are potentially life threatening. Wiring to these terminals requires installation by an instructed person or the use of ready-made leads or cords. Custom wiring should only be made by qualified personnel. [. . . ] frequency @ 0 W / 8 (Ch => Ch2, Ch2 => Ch) (Measurements of a typical performance of D-POWER 3)
P. 28
USER MANUAL D - P O W E R SERIES
D-POWER
SERIES
7 TYPICAL PERFORMANCE DIAGRAMS
2275
2500 500
365 22
2000
900 225 22 630
500 000 Watts
500 Watts 000
730 695 378 370
500 0 4 8
Impedance/
608 Peak power Distortion limited output power ( % THD)
0 4 8
Impedance/
Peak power Distortion limited output power ( % THD)
6
6
Figure 8. 3 D-POWER 4 (Measurements of a typical performance)
800
2000
Figure 8. 5 D-POWER 2 (Measurements of a typical performance)
600
500 Watts 000
960 95 500
500
483 Peak power
4
Impedance/
0 8 6
Distortion limited output power ( % THD)
Figure 8. 4 D-POWER 3 (Measurements of a typical performance)
P. 29
USER MANUAL D - P O W E R SERIES
D-POWER
SERIES
8 WARRANTY INFORMATION
8. Summary of Warranty CAMCO guarantees the D-POWER Amplifier to be free from defective material and/or workmanship for a period of six (6) years from the date of sale. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CAMCO D-POWER 2 Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CAMCO D-POWER 2 will begin.