[. . . ] The total power consumption of 24 V accessories must not exceed 20W. Safety Photocells can be connected to obtain: -Re-opening during the closing cycle (2-
C1); -Re-closing during the opening cycle (2-CX, see dip 8-9); -Partial stop, shutdown of moving gate, with activation of an automatic closing cycle (2-CX, see dip 8-9); -Total stop (1-2), shutdown of gate movement without automatic closing; a pushbutton or radio remote control must be actuated to resume movement; N. B: If an NC safety contact (2-C1, 2CX, 1-2) is opened, the LED will flash to indicate this fact; -Obstacle presence detection. When the motor is stopped (gate is closed, open or half-open after an emercency stop command), the transmitter and the control pushbutton will be deactivated if an obstacle is detected by one of the safety devices (for example, the photocells); -Safety test function. [. . . ] The control unit will now check the safety system every time an opening or closing command is given (see pag. Accessories which can be connected -Cycle lamp or courtesy light (60 Watt, see pag. 16); Other functions -Automatic closing: The automatic closing timer is automatically
-4-
activated at the end of the opening cycle. The preset, adjustable automatic closing time is automatically interrupted by the activation of any safety system, and is deactivated after a STOP command or in case of power failure; -Partial opening. Opening of the gate to allow for foot traffic; activated by connecting to terminals 2-3P and adjusted with the AP-PARZ. With this function, the automatic closing can vary in the following way: 1) Dip 12 set to ON: after a partial opening, the time for automatic closing functions independently of the adjustment of the TCA trimmer and of the position of Dip 1; it is set at 8 seconds. 2) Dip 12 set to OFF: after a partial opening, the time for automatic closing is adjustable only if Dip 1 is set to ON. The lamp which lights the manoeuvring zone: it remains lit from the moment the doors begin to open until they are completely closed (including the time required for the automatic closure). In case automatic closure is not enabled, the lamp remains lit only during movement (EEX), see p. "Master" refers to the motor that controls both the gates. On the control board of the 2nd motor, set dip-switch 11 to ON to make it the "slave" (1). - Make sure that the radio receiver is activated only on the MASTER board (2); - Wire the electrical connections and the normally used selections only on the MASTER terminal board (3); - Wire the electrical connections between the terminal boards, as shown in the Fig. A; - Make sure that all the dip-switches on the board of the 2nd motor are (OFF), except for dip 11 (4). NB: If the two coupled gates are of different sizes, the master function must be fitted to the motor control board installed on the longer door. 92 MHz (TOP and TAM series), position the jumper connection on circuit card AF43S as shown on the sheet. Plantear el código en el dip-switch C y el canal en D (P1=CH1 y P2=CH2, planteamiento por defecto)
D
P1 P2
1
2
3
4
1
2
3
4
5
6
7
8
9
10
P1
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
CH1
CH2
4 1 2 3 4
CH3
1 2 3 4
CH4
1 2 3 4
C
T434M - T314M
P1=CH1 P2=CH2 P3=CH3 P4=CH4
P2
1 2 3
CH1
CH2
CH3
CH4
T432S / T432SA / T434MA
vedi istruzioni su confezione see instructions on pack voir instructions sur l'emballage Siehe Anleitungen auf der Packung. ver instrucciones en el embalaje
P1 P3
P2 P4
impostare solo il codice set code only ne saisir que le code Stellen Sie nur den Code ein. Plantear sólo el código
1
2
3
4
5
6
7
8
9
10
C TAM
T432 T434 T438
vedi foglio istruzioni inserito nella confezione
TFM
T132 T134 T138 T152 T154 T158
see instruction sheet inside the pack
voir la notice d'instructions qui se trouve dans l'emballage
Siehe Anleitungen, die der Packung beiliegen. [. . . ] Plantear sólo el código
1
2
3
4
5
6
7
8
9
10
C TAM
T432 T434 T438
vedi foglio istruzioni inserito nella confezione
TFM
T132 T134 T138 T152 T154 T158
see instruction sheet inside the pack
voir la notice d'instructions qui se trouve dans l'emballage
Siehe Anleitungen, die der Packung beiliegen. B The first encoding operation must be carried out whilst keeping the J jumpers positioned for channels 1 and 2 as per fig. B for any subsequent settings on different channels. ENGLISH -While holding down key "CH1", press the control key on the transmitter after the signal LED lights up. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CAME ARGO A1824
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.