User manual CAME AT01

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CAME AT01. We hope that this CAME AT01 user guide will be useful to you.

Lastmanuals help download the user guide CAME AT01.


Mode d'emploi CAME AT01
Download
Manual abstract: user guide CAME AT01

Detailed instructions for use are in the User's Guide.

[. . . ] The AT01 control panel is open or half-open after an emercency factory set for 400V power supply. If stop command), the transmitter and the power supply is 230V, it is the control pushbutton will be necessary to move the jumper which deactivated if an obstacle is detected short-circuit terminals «380» and by one of the safety devices (for «COM» so that it short-circuits example, the photocells); terminals «220» and «COM» (see -Safety test function. The Control systems are will now check the safety system powered by low voltage and protected every time an opening or closing with a 2A fuse. [. . . ] Accessories which can be Fixed operating time of 150 seconds. A light that illuminates the manoeuvring zone; after an opening command, the light remains on for a fixed time of 5 minutes and 30 secOther functions onds (E-EX), see page 16; -Automatic closing: The automatic -"Operator present" function: Gate closing timer is automatically activated operates only when the pushbutton is at the end of the opening cycle. The held down (the radio remote control preset, adjustable automatic closing system is deactivated); time is automatically interrupted by the - Pre-flashing for 5 seconds, while the activation of any safety system, and is door is opening and closing; deactivated after a STOP command or - Master function; the panel assumes in case of power failure; all the command functions when two -Partial opening. Opening of the gate to paired motors are used (see page 30); - Slave function; this panel is excluallow for foot traffic; activated by connecting to terminals 2-3P and sively controlled by the “MASTER” (see page 30); adjusted with the AP-PARZ. - Enabling functions of partial stop or With this function, the automatic closing can vary in the following way: re-closure during opening, normallyclosed contact (2-CX), select one of 1) Dip 12 set to ON: after a partial opening, the time for automatic closing the two functions by setting dip (see functions independently of the adjustselection of functions); ment of the TCA trimmer and of the po- - Type of command: sition of Dip 1; it is set at 8 seconds. -open-close-reverse by button and transmitter; 2) Dip 12 set to OFF: after a partial opening, the time for automatic closing -open-stop-close-stop by button and is adjustable only if Dip 1 is set to ON. The lamp which lights the -open only by transmitter. Manoeuvring zone: it remains lit from the moment the doors begin to open Adjustments - Automatic closure time; until they are completely closed (including the time required for the - Partial opening time. In case automatic closure is not enabled, the lamp Important!On the control board of the 2nd motor, set dip-switch 11 to ON to make it the "slave" (1). - Make sure that the radio receiver is activated only on the MASTER board (2); - Wire the electrical connections and the normally used selections only on the MASTER terminal board (3); - Wire the electrical connections between the terminal boards, as shown in the Fig. A; - Make sure that all the dip-switches on the board of the 2nd motor are (OFF), except for dip 11 (4). NB: If the two coupled gates are of different sizes, the master function must be fitted to the motor control board installed on the longer door. 92 MHz (TOP and TAM series), position the jumper connection on circuit card AF43S as shown on the sheet. Plantear el código en el dip-switch C y el canal en D (P1=CH1 y P2=CH2, planteamiento por defecto) D P1 P2 1 2 3 4 1 2 3 4 5 6 7 8 9 10 P1 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 CH1 CH2 4 1 2 3 4 CH3 1 2 3 4 CH4 1 2 3 4 C T434M - T314M P1=CH1 P2=CH2 P3=CH3 P4=CH4 P2 1 2 3 CH1 CH2 CH3 CH4 T432S / T432SA / T434MA vedi istruzioni su confezione see instructions on pack voir instructions sur l'emballage Siehe Anleitungen auf der Packung. ver instrucciones en el embalaje P1 P3 P2 P4 impostare solo il codice set code only ne saisir que le code Stellen Sie nur den Code ein. Plantear sólo el código 1 2 3 4 5 6 7 8 9 10 C TAM T432 T434 T438 vedi foglio istruzioni inserito nella confezione TFM T132 T134 T138 T152 T154 T158 see instruction sheet inside the pack voir la notice d'instructions qui se trouve dans l'emballage Siehe Anleitungen, die der Packung beiliegen. B The first encoding operation must be carried out whilst keeping the J jumpers positioned for channels 1 and 2 as per fig. [. . . ] B for any subsequent settings on different channels. ENGLISH -While holding down key "CH1", press the control key on the transmitter after the signal LED lights up. When the key is pressed, the LED will flash briefly to signal that the command has been stored (figure 1). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CAME AT01

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CAME AT01 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag