Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CAME AXO AX3024. We hope that this CAME AXO AX3024 user guide will be useful to you.
Lastmanuals help download the user guide CAME AXO AX3024.
Detailed instructions for use are in the User's Guide.
[. . . ] 2 (twoway function selector) positioned in ON; - Total stop (1-2), shutdown of gate movement without automatic closing; a pushbutton or radio remote control must be actuated to resume movement). NB: If an NC safety contact (2-C1, 2-CX, 1-2) is opened, the LED (n°12) will flash to indicate this fact. The control unit will now check the safety system every time an opening or closing command is given (see p. Moment the doors begin to open until they are completely closed (including the time ACCESORIOS CONECTABLES required for the automatic closure). [. . . ] Si no se habilita el ing timer is automatically activated cierre automático, el cierre permaneat the end of the opening cycle. The pre- ce encendido sólo durante el movimienset, adjustable automatic closing time is to (E-E3). Automatically interrupted by the activation - Cerradura eléctrica (11-S); of any safety system, and is deactivated OTRAS FUNCIONES after a STOP command or in case of powSELECCIONABLES er failure;
I TA L I A N O — E N G L I S H — E S PA Ñ O L
- Obstacle presence detection: When the motor is stopped (gate is closed, open or half-open after an emergency stop command), the transmitter and the control pushbutton will be deactivated if an obstacle is detected by one of the safety devices (for example, the photocells); - Hammer movement. At every opening command, the wings press the closing stop-ledge for a second, thus facilitating the release operation of the electric lock connected to terminals 11-S. It is only active if the wings are closed and at the end of the work time or at the 1st manoeuvre after the system has been powered;
- Cierre automático. - "Operator present" function: Gate operates only when the pushbutton is held down (the radio remote control system is deactivated); - Pre-flashing. After an opening or closing command, the flasher connected to the W-E flashes for 5 seconds before beginning the procedure; - Partial opening, the opening of the second motor’s door, controlled by the TRM2 trimmer, is activated by connecting it to the 2-3P terminals. Select dip switch n°1 set to ON, two- way selector; - Pedestrian opening, the total opening of the second motor’s door is activated by connecting it to the 2-3P terminals Select dip switch n°1 set to OFF, two-way selector: Note: if the partial or pedestrian opening command is activated after restoring the power supply, both doors will open completely. the 2-3P contact has a step-by-step function. This function is activated during the closing mode or when the motor is shut down in an open position, reversing the doors’ direction. IMPORTANT: When the safety test function is performed, check that there are no jumpers between contacts 2-CX, 2-C1 and, if not being used, exclude them using dip switches 8 and 9. 18-19) attivato; (10 OFF-disattivato)
Automatic closure enabled; (1OFF-desabled) 2 ON "Open-stop-close-stop" function with button (2-7) and radio control (AF board inserted) enabled; 2 OFF "Open-close" function with button (2-7) and radio control (AF board inserted) enabled; 3 ON "Only opening" function with radio control (AF board inserted) enabled; (3OFF-desabled) 4 ON Pre-flashing (opening and closing) enabled; (4OFF-des. ) 5 ON Obstacle detection device enabled; (5OFFdes. ) 6 OFF "Operator present" (radio remote control is deactivated when function is selected) desabled; (6ON-enabled) 7 ON Hammer movement enabled; (this function helps unlock the electric lock) 7OFF-desabled 8 OFF Re-closure during opening or partial stop, connect safety device to terminals 2-CX (two-way selector, see p. 23); (if the devices on the 2-CX terminals are not used, set Dip 8 in ON) 9 OFF Re-opening in closing phase (connect the safety device on terminals 2-C1) enabled; if not used, set the dip-switch to ON 10 ON Activates safety test that checks the photocells proper operation (see p. 1 ON
1 OFF
2 ON
2 OFF
Partial opening activated; with command device connected to terminals 2-3P; Pedestrian opening activated; with command device connected to terminals 2-3P; Partial stop activated; with safety device connected to terminals 2CX; Reclosing during opening activated; with safety device connected to terminals 2-CX. 92 MHz (TOP and TAM series), position the jumper connection on circuit card AF43S as shown on the sheet. B The first encoding operation must be carried out whilst keeping the jumpers positioned for channels 1 and 2 as per fig. B for any subsequent settings on different channels. B
P1=CH1 - P2=CH3 P1=CH1 P2=CH2
P1=CH3 - P2=CH2
J
P1=CH1 - P2=CH4
T264M - T304M
P1=CH3 - P2=CH4
T2622M - T3022M
1° codice/codice/ codice
P1 P3 P2 P4
P1=CH1 P2=CH2
2° codice/codice/codice
P1=CH1 - P2=CH2 P3=CH3 - P4=CH4
P1 P3 P2 P4
P1 P2
J
OFF ON
J
P3=CH1 P4=CH2
-14-
C
a) press down and hold the "CH1" key on the base board (the signal LED will flash); b) send the code with a button on the transmitter, the LED will remain lit to indicate that the data has been saved place . [. . . ] B
P1=CH1 - P2=CH3 P1=CH1 P2=CH2
P1=CH3 - P2=CH2
J
P1=CH1 - P2=CH4
T264M - T304M
P1=CH3 - P2=CH4
T2622M - T3022M
1° codice/codice/ codice
P1 P3 P2 P4
P1=CH1 P2=CH2
2° codice/codice/codice
P1=CH1 - P2=CH2 P3=CH3 - P4=CH4
P1 P3 P2 P4
P1 P2
J
OFF ON
J
P3=CH1 P4=CH2
-14-
C
a) press down and hold the "CH1" key on the base board (the signal LED will flash); b) send the code with a button on the transmitter, the LED will remain lit to indicate that the data has been saved place . Perform the same procedure with the "CH2" key, associating it with another transmitter key . CH1 = Channel for direct control of one function performed by the control unit on the gear motor ("open only" / "open-closereverse" or "open-stop-close-stop", depending on the position of dip switches 2 and 3). CH2 = Channel for direct control of an accessory connected across B1-B2. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CAME AXO AX3024
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CAME AXO AX3024 will begin.