User manual CAME BK1810

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CAME BK1810. We hope that this CAME BK1810 user guide will be useful to you.

Lastmanuals help download the user guide CAME BK1810.


Mode d'emploi CAME BK1810
Download
Manual abstract: user guide CAME BK1810

Detailed instructions for use are in the User's Guide.

[. . . ] Guaranteed 24 months, unless tampered with. Control systems are powered by low voltage and protected by a 315mA-F fuse. The total power consumption of 24V accessories (which are protected by a 2A-F fuse) -> The transformers are equipped with a guard, must not exceed 40 W. [. . . ] SAFETY They are closed again only after the temperature falls below the overload threshold. -> Photocells can be connected to obtain: • Re-opening during the closing cycle (2ACCESSORIES WHICH CAN BE C1), if the photocells identify an obstacle CONNECTED TO THIS UNIT while the gate is closing, they will reverse the direction of movement until the gate -> “Gate open” signal light; is completely open; • Partial stop (2-C3), shutdown of mov- -> Flashing signal light when gate is in motion ing gate, with activation of an automatic -> Cycle lamp closing cycle; • Total stop (1-2), shutdown of gate -> Electric lock; movement without automatic closing; a -> LB18 circuit card for emergency battery, pushbutton or radio remote control must which is automatically connected in case of be actuated to resume movement). Power failure; battery is recharged when line -> The control board includes an amperometric power is restored sensor for the motors which is activated when -> Radiofrequency AF board (see table page an obstruction blocks the opening and closing 30). -4- -> Type of command: (see pages 22 through 26) • «open-stop-close-stop» for pushbutton and radio transmitter; -> Automatic closing. The automatic closing • «open-close-reverse» for pushbutton timer is automatically activated at the end of and radio transmitter; the opening cycle. • «open only» for radio transmitter. The preset, adjustable automatic closing time is automatically interrupted by the activaADJUSTMENTS tion of any safety system, and is deactivated after a STOP command or in case of power -> Trimmer FINE ADJ/AMP SENS= Fine adjustfailure; ment of amperometric sensitivity during motor operation: min/max; -> Photocells safety test. The control unit will now check the safety system every time an -> Trimmer AMP SENS = Adjustment of amperopening or closing command is given (4 dip ometric sensitivity during operating: min/max; switch selector). -> Trimmer SLOWDOWN/AMP SENS = Ad-> Obstacle detection. IMPORTANT: When the safety test function is performed, check that there are no jumpers between contacts 2-C3, 2-C1 and, if not being used, exclude them using dip switches 8 and 10. 22) Non utilizzato ENGLISH FRANÇAIS 1 2 3 ON 4 Must stay OFF Must stay OFF Activates safety test that checks the photocells proper operation (see p. 3) with the “adjust microswitches” procedures shown in the gearmotor’s manual… …take the template - which is supplied with the control panel - and hold it up against one of the two mechanical stops as shown in fig. 1 (adjustment is to be made either on the closing endstop or opening endstop). Activate the gate - either using a command button or the remote control - and turn the OP TIME trimmer clockwise until the gate leaf inverts its direction just as it touches the obstacle/template. Then turn the template from its short side (fig. 2) and turn the OP TIME trimmer counterclockwise until the gate leaf stops against the obstable/template. With two-leaved gates, this procedure must be performed on either side. 92 MHz (TOP and TAM series), position the jumper connection on circuit card AF43S as shown on the sheet. [. . . ] 92 MHz (TOP and TAM series), position the jumper connection on circuit card AF43S as shown on the sheet. ENGLISH Keep the CH1 key pressed on the base card (the signal LED will flash), and with a key on the transmitter the code is sent, the LED will remain lit to signal the successful saving of the code (figure 1). Perform the same procedure with the "CH2" key, associating it with another transmitter key (figure 2). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CAME BK1810

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CAME BK1810 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag