Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CAME BK2200T. We hope that this CAME BK2200T user guide will be useful to you.
Lastmanuals help download the user guide CAME BK2200T.
Detailed instructions for use are in the User's Guide.
[. . . ] Dimensions of the ZL80 container
240
145
Dimensions of the BK2200T container
320
240
165
4
Tutti i dati e le informazioni quì contenute sono da ritenersi suscettibili di modifica in qualsiasi momento e a nostro giudizio
320
Emglish
Tutti i dati e le informazioni quì contenute sono da ritenersi suscettibili di modifica in qualsiasi momento e a nostro giudizio
21
5
The pre-punched holes have a 20/21 mm diameter
295
5. 4 Spessori minimi e tipo cavi
Connections Power supply line, 230/400V 3F Power supply line, 230V 2F Motors, 230/400V 2F/3F Motor, 24V Flashing lamp 230V Flashing lamp 24V Cycle/courtesy lights 230V Power supply accessories 24V Warning light 24V Output 24V “in motion” Safety contacts N. Control buttons End stop 2nd motor control Antenna connection (max 50m) Encoder connection (max 30m)
Cable type
Cable length 1<10 M 4G 1, 5mm² 3G 1, 5mm² 4G 1mm² 2 x 1mm² 2 x 0, 5mm² 2 x 0, 5mm² 3G 0, 5mm²
Cable length 10<20 M 4G 2, 5mm² 3G 2, 5mm² 4G 1, 5mm² 2 x 1, 5mm² 2 x 1mm² 2 x 1mm² 3G 1mm² 2 x 0, 5mm² 2 x 0, 5mm² 2 x 0, 5mm² 2 x 0, 5mm² 2 x 0, 5mm² 3 x 1mm² 1 x 0, 5mm²
Cable length 20<30 M 4G 4mm² 3G 4mm² 4G 2, 5mm² 2 x 2, 5mm² 2 x 1, 5mm² 2 x 1, 5mm² 3G 1, 5mm² 2 x 1mm² 2 x 1mm² 2 x 1mm² 2 x 0, 5mm² 2 x 0, 5mm² 3 x 1, 5mm² 1 x 1mm²
FROR CEI 20-22 CEI EN 50267-2-1
2 x 0, 5mm² 2 x 0, 5mm² 2 x 0, 5mm² 2 x 0, 5mm² 2 x 0, 5mm² 3 x 0, 5mm² 1 x 0, 5mm²
RG58 Insulated cable 2402C 22AWG
PLEASE NOTE: If the cable length differs from that specified in the table, then you must determine the cable diameter on the basis of the actual power draw from the connected devices and depending on the standards specified in CEI EN 60204-1. [. . . ] Time > < > ESC 20 sec
ENTER
EXAMPLE PROGRAMMING FUNCTION
PROGRAMMING FUNCTION the smaller ESC When than/ greater than <> symAuto Clo. Time > bols are on the TIME ESC 20 sec function, its values may < ESC be changed. then press ENTER
< <
>
>
ENTER
<
PROGRAMMING FUNC To increase or reduce the value use the smaller > ENTER than/greater than keys ENTER
PROGRAMMING FUNCTION
ESC
Auto Clo. Time
<
<
45 < ESC sec
>
> >
ENTER
ENTER
…to exit the menu, wait 30 seconds, or press ESC, until the initial screen reappears
…then press ENTER to confirm… Please note: when the menu is active the system cannot be used. 4 Description of menu items Language
Select language: select the menu language among those available. Select LANGUAGE
ENTER
Italian
>
>
English
>
>
French
>
>
Emglish
German
Spanisch
Dutch
Time intervals
Time of operation: operating time intervals of the gearmotor during the opening phase or closing phase (from 10” o 120”)
TIMES
ENTER
Oper. : automatic closing time following an opening command (from 1” to 120”). : automatic closing time following a pedestrian opening command (from 1” to 120”). ENTER > x3 Courtesy time TIMES
Functions
ENTER
< 10 sec >
< >
Automatic Closing: activates or deactivates the automatic closing function
FUNCTIONS
ENTER
>
Automatic cl. ENTER
>
New user Vedere descrizione dettagliata
Sensitive Safety Strip obstacle detector (obstruction detection sensor): adjusts the gate’s sensitivity, when obstructions are detected during motion. ENTER
+oooo•
< >
Partial opening travel run: adjusts the partial opening travel run. Run
ENTER
< 40%
< >
>
Web/Network Address: assigns a value of between 1 and 16 for purposes of software recognition. ENTER
>
x4
Network ID
ENTER
< >
INFO
1 <-> 16
Version: Visualises the software version Number of cycles: visualises the number cycles made. Welcome message: to set the welcome message on the display. PROGRAMMING FUNCTION 1 Perform a complete opening run using (<>), until the complete opening occurs. >
ESC
<
>
ENTER
ESC
<
>
ENTER
Carry out a complete closing run using (<>), until the leaf is completely closed. pROGRAMMING FUNCTION
Do a full closing Run
4
5
Press ENTER to confirm. 6 – Set the gate leaf in motion for at least 3”
PROGRAMMING FUNCTION
6
Set
opening dir ENT:OK
<>:move
ESC
<
>
ENTER
ESC
<
>
ENTER
7
Press ENTER to confirm. [. . . ] Press ENTER to confirm
PROGRAMMING FUNCTION
1
Choose the function associated with the user (User Function or Partial Opening). A code will be required which may inserted with a remote control, a slide-through card or a transponder, depending on the type of sensors installed in the system at hand
3
Once the remote control or card code has been added, the word Memorised will appear on the screen (if the code has yet to be added), or the word On file (if the code has already been added). Cod
In any case a window will appear asking whether we wish to add a new PROGRAMMING FUNCTION code or not. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CAME BK2200T
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CAME BK2200T will begin.