[. . . ] In order to allow for alignment, anchorage of the rack and further adjustments. Perfect alignment with the guide rail is made possible by the (paten-ted) built-in regulation system, wich consists of: - slots for horizontal adjustment; - threaded steel feet for vertical adjustment and levelling; - plates and bolts for anchorage to the base. Regolazione orizzontale e fissaggio Horizontal adjustment unit and achorage Regulación horizontal y fijación
Regolazione verticale - messa in bolla Vertical adjustment and unit leveling Regulación vertical y nivelación
CAME
Ingresso cavi Cable entrances Entrada cables
(5÷ ATTACHING THE RACK/LIMIT Attach the rack to the gate as described below: - position the rack on the pinion of the gearmotor and slide the gate manually in order to attach the rack along its entire lenght; - when the rack is attached to the gate, adjust the feet using a screwdriver until the play between the pinion and the rack is correct (1-1, 5 mm. : This play ensures that the weight of the gate does not rest on the until. [. . . ] B on the threelobed pin and turning it in the Desbloqee el motorreductor aplicando direction indicated. ATTENTION: the opening of the unblock panel arrests the motor. 0
TECHNICAL DESCRIPTION ZBK2210 The siren sounds for 5 minutes, after which it automatically silences. You can silence the siren during this time by pressing the stop pushbutton. Whenever the automation triggers the alarm, to reset normal functioning, you must press the manual opening (or closing) pushbutton. Before manual reset, all remote control functions are excluded. OTHER SELECTABLE FUNCTIONS Automatic closure: The automatic-close timer self-powers when reaching the fully-open end-stop. The programmable preset time however depends on the intervention of any safety accessories system and is cancelled after a total “stop” or power failure; “Maintained action” function: Gate operation, by keeping the pushbutton pressed (excludes the remote-control function); Partial opening: Gate opening is activated by connecting the 2-3P terminals and is adjustable by the P. OPENING trimmer With this function, automatic closure can vary in the following way: 1) DIP SWITCH no. 1 ON “automatic closure active”: After a partial opening, the closure time is 8”. If the ACT (Automatic Closing Time) trimmer is set to the minimum after a partial opening, the automatic closure count does not start. electrical connections required for safety test function. Photocell lamps and sensors must be connected as follows: - The photoelectric cell transmitters and receivers must be connected as shown in fig. IMPORTANT: When performing the safety test function, contacts 2-C1, 2-C2 and 2-C3 must not be short-circuited but excluded via dip switches 7, 8 and 9. Safety device (photoelectric cell, DOC) N. ) If not used, short circuit it Pulsador de stop (N. ) for «re-aperture during closure» Safety equipment (photoelectric cells, etc. 92 MHz (TOP and TAM series), position the jumper connection on circuit card AF43S as shown on the sheet. B The first encoding operation must be carried out whilst keeping the jumpers positioned for channels 1 and 2 as per fig. B for any subsequent settings on different channels. -Keep the CH1 key pressed on the base card (the signal LED will flash), and with a key on the transmitter the code is sent, the LED will remain lit to signal the successful saving of the code (figure 1). Perform the same procedure with the CH2 key, associating it with another transmitter key (figure 2). [. . . ] If right-hand installation is desired: - invert limit switch connections FA-FC on the terminal block; - invert motor phase connections M-N on the terminal block. - Check the 24 V power on terminals 10-11 - Check the stop button connection; if it is not active, jumper it on terminals 1-2. - Check that the small access panel for blocking/release is closed
THE GATE REMAINS IN THE OPEN POSITION:
- Controle la tensión 230V AC en los bornes L-N. - “Maintained Action” command activated, see setting of dip no. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CAME BK2210
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.