User manual CAME BKE1800

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CAME BKE1800. We hope that this CAME BKE1800 user guide will be useful to you.

Lastmanuals help download the user guide CAME BKE1800.


Mode d'emploi CAME BKE1800
Download
Manual abstract: user guide CAME BKE1800

Detailed instructions for use are in the User's Guide.

[. . . ] The senregulations in force and with IP 54 level of sor's sensitivity can be adjusted using the protection. Housing in ABS is equipped with vents to The transformers are equipped with a provide internal air circulation. Guaranteed guard, which in case of thermal overload will 24 months, unless tampered with. [. . . ] Control systems are powered by low voltage old. The total power consumption of 24V acces- Accessories which can be connected to sories (which are protected by a 3. 15A fuse) this unit must not exceed 40 W. Safety Photocells can be connected to obtain: - Re-opening during the closing cycle (2C1), if the photocells identify an obstacle while the gate is closing, they will reverse the direction of movement until the gate is completely open; - Partial stop, shutdown of moving gate, with activation of an automatic closing cycle (2-C3); - Total stop (1-2), shutdown of gate movement without automatic closing; a pushbutton or radio remote control must be actuated to resume movement). The control unit will now check the safety system every time an - “Gate open” signal light; - Flashing signal light when gate is in motion - Electric lock; - LB18 circuit card for emergency battery, which is automatically connected in case of power failure; battery is recharged when line power is restored - Radiofrequency AF board (see table pag. The automatic closing timer is automatically activated at the end of the opening cycle. The preset, adjustable automatic closing time is automatically interrupted by the activation of any safety system, and is deactivated after a STOP command or in case of power failure; -4- - Obstacle detection: When the motor is stopped (gate is closed, open or half-open after an emergency stop command), the transmitter and the control pushbutton will be deactivated if an obstacle is detected by one of the safety devices (for example, the photocells); - Hammer movement: This feature makes it easy for the lock to release (the door wings momentarily press against the closure stops when the open command is given, which facilitates release of the electric lock); - Cycle lamp. The lamp which lights the manoeuvring zone: it remains lit from the moment the doors begin to open until they are completely closed (including the time required for the automatic closure). It allows the gearcase to check the efficiency of the safety devices (photoelectric cells) after each command to open or close. Any anomaly of the photoelectric cells is identified with a flash of the LED on the control panel; therefore all functions of the remote control and buttons are cancelled. electrical connection for safety-test functioning. The transmitters and the receivers of the photoelectric cells must be connected as illustrated in figs. IMPORTANT: When the safety test function is performed, check that there are no jumpers between contacts 2-C3, 2-C1 and, if not being used, exclude them using dip switches 8 and 10. 27) Non utilisé 1 OFF-2 OFF Selects operation with FROG/FERNI gearmotors; 3 ON Activates safety test that checks the photocells proper operation (see p. 92 MHz (TOP and TAM series), position the jumper connection on circuit card AF43S as shown on the sheet. B The first encoding operation must be carried out whilst keeping the jumpers positioned for channels 1 and 2 as per fig. [. . . ] B for any subsequent settings on different channels. Plantear el código en el dip-switch C y el canal en D (P1=CH1 y P2=CH2, planteamiento por defecto) D P1 CH1 CH2 CH3 CH4 C T434M - T314M P1=CH1 P2=CH2 P3=CH3 P4=CH4 P2 CH1 CH2 CH3 CH4 TOP-432S / TOP-432NA / TOP-434NA vedi istruzioni su confezione see instructions on pack voir instructions sur l'emballage Siehe Anleitungen auf der Packung. ENGLISH Keep the CH1 key pressed on the base card (the signal LED will flash), and with a key on the transmitter the code is sent, the LED will remain lit to signal the successful saving of the code (figure 1). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CAME BKE1800

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CAME BKE1800 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag