[. . . ] Perfect alignment with the guide rail is made possible by the (patented) built-in regulation system, wich consists of: - slots for horizontal adjustment; - threaded steel feet for vertical adjustment and levelling; - plates and bolts for anchorage to the base. Install the rack with the gate at the half-way point. - allow the door to reach mid-run, set the rack on the rationmotor's pinion and slide the gate manually, fixing the rack's entire lenght; - The gate's maximum run is 14 m; - when the rack is attached to the gate, adjust the feet using a screwdriver until the play between the pinion and the rack is correct (1-2 mm. : This position ensures that the weight of the gate does not rest on the gearmotor. [. . . ] - If the rack is already attached, proceed directly to the adjustment of the rack/pinion coupling. - When the necessary adjustment have been completed, fasten the unit in position by tightening the two anchor bolts. - To open the access door, insert the key, push down and rotate clockwise. Now, release the gear motor by rotating the knob in the direction shown. ATTENTION: the opening of the unblockpanel arrests the motor. WARNING: after three consecutive inversions, the gate will remain open and automatic closure will be discontinued. To close the gate, use the radio remote control or the push-button. accessories which can be connected - Cycle lamp. The lamp which lights the manoeuvring zone: it remains lit from the moment the gate begin to open until it is completely closed (including the time required for the automatic closure). The function of the cycle lamp is obtained in output 10-E1 only if dip switch numbers: No. It is a light that indicates the sliding gate's open position and turns off when the gate activates the closing end-stop, connect it to terminal blocks 10-5. BATTERIE DI EMERGENZA (12V-1, 2Ah) ESCLUSE STANDBY BATTERY (12V-1, 2Ah, NOT INCLUDED) BATTERIES D'URGENCE (12V-1, 2Ah) EXCLUES NOTBATTERIEN (12V-1, 2Ah) AUSGESCHLOSSEN BATERIAS DE EMERGENCIA (12V-1, 2Ah) EXCLUIDAS
-
-
BATTERIA
A
B
C
D
ENGLISH
SCHEDA BASE ZBX ZBX MOTHERBOARD CARTE DE BASE ZBX BASISKARTE ZBX TARJETA BASE ZBX
The BN1 board allows the automation to be battery operated in case of a power outage. When power is restored, the card also recharges the batteries. - Place the batteries in the special holder and (using the leads supplied) connect to terminal (+, -) of motherboard ZBXE24 (Fig. RED LED: Signals that system is running on emergency batteries. RED LED: Signals that system is running on emergency batteries. 9 10
3
4
5
6
7
8
1
«MASTER»
ON
1
2
2
SCHEDA RADIOFREQUENZA "AF" "AF" RADIO FREQUENCY BOARD CARTE FREQUENCE RADIO "AF" RADIOFREQUENZKARTE «AF» TARJETA RADIOFRECUENCIA
ENGLISH
In case two combined motors are installed, proceed in the following manner: - Match the directions in which gear motors A and B rotate by changing the direction in which motor B rotates (see limit switch); - Set the master (or pilot) motor between A and B by setting dip-switch 6 to ON on the control board (1). "Master" refers to the motor that controls both the gates. - Check that the (AF) radio receiver is activated only on the MASTER board (2); - Make the electrical connections and the normally used selections only on the MASTER terminal board (3); - Wire the electrical connections between the terminal boards, as shown in the "Figure A"; - Make sure that all the dip-switches on the board of the 2nd motor are (OFF)4. NB: If the two coupled gates are of different sizes, the master function must be fitted to the motor control board installed on the longer door. 92 MHz (TOP and TAM series), position the jumper connection on circuit card AF43S as shown on the sheet. B
2° codice/codice/codice/codice/codice
P1 P2
J
OFF ON
The first encoding operation must be carried out whilst keeping the jumpers positioned for channels 1 and 2 as per fig. [. . . ] 92 MHz (TOP and TAM series), position the jumper connection on circuit card AF43S as shown on the sheet. B
2° codice/codice/codice/codice/codice
P1 P2
J
OFF ON
The first encoding operation must be carried out whilst keeping the jumpers positioned for channels 1 and 2 as per fig. B for any subsequent settings on different channels. Plantear sólo el código
1
2
3
4
5
6
7
8
9
10
C
vedi istruzioni su confezione see instructions on pack voir instructions sur l'emballage Siehe Anleitungen auf der Packung. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CAME BX
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.