Manual abstract: user guide CAME C1-C2F

Detailed instructions for use are in the User's Guide.

[. . . ] Safety Photocells can be connected to obtain: - Re-opening during the closing cycle (2-C1); - Re-closing during the opening cycle (2-CX, see dip 8-9); - Partial stop, shutdown of moving gate, with activation of an automatic closing cycle (2-CX, see dip 8-9); - Total stop (1-2), shutdown of gate movement without automatic closing; a pushbutton or radio remote control must be actuated to resume movement; Note: If an normally closed safety contact (2-C1, 2-CX, 12) is opened, the LED (n°11) will flash to indicate this fact; - Obstacle presence detection. When the motor is stopped (gate is closed, open or half-open after an emercency stop command), the transmitter and the control pushbutton will be deactivated if an obstacle is detected by one of the safety devices (for example, the photocells); - Safety test function. The control unit will now check the safety system every time an opening or closing command is given (see pag. [. . . ] Other functions - Automatic closing: The automatic closing timer is automatically activated at the end of the opening cycle. The preset, adjustable automatic closing time is automatically interrupted by the activation of any safety system, and is deactivated after a STOP command or in case of power failure; - Partial opening. Opening of the gate to allow for foot traffic; activated by connecting to terminals 2-3P and adjusted with the AP-PARZ. With this function, the automatic closing can vary in the following way: 1) Dip 12 set to ON: after a partial opening, the time for automatic closing functions independently of the adjustment of the TCA trimmer and of the position of Dip 1; it is set at 8 seconds. 2) Dip 12 set to OFF: after a partial opening, the time for automatic closing is adjustable only if Dip 1 is set to ON. The lamp which lights the manoeuvring zone: it remains lit from the moment the doors begin to open until they are completely closed (including the time required for the automatic closure). In case automatic closure is not enabled, the lamp remains lit only during movement (E-EX); - Courtesy Light. A light that illuminates the manoeuvring zone; after an opening command, the light remains on for a fixed time of 5 minutes and 30 seconds (E-EX, see page 8); - "Operator present" function: Gate operates only when the pushbutton is held down (the radio remote control system is deactivated); - Pre-flashing for 5 seconds, while the door is opening and closing; - Master function; the panel assumes all the command functions when two paired motors are used (see page 13); - Slave function; this panel is exclusively controlled by the “MASTER” (see p. On the control board of the 2nd motor, set dip-switch 11 to ON to make it the "slave" (Fig. -Make sure that the radio receiverisactivatedonlyon theMASTERboardFig. 2; -Wire the electrical connections and the normally usedselectionsonlyonthe MASTER terminal board Fig. 3; -Wire the electrical connectionsbetweentheterminalboards, asshowninthe «figure A», and make sure that the automatic closing function is enabled for the "master"motoranddisabled for 2nd motor; - Make sure that all the dipswitchesontheboardofthe 2nd motorare(OFF), except for dip 11 (Fig. Important: set the motor's stoplimitssothattheMASTERmotor'sdoorreaches closing position after the SLAVEmotor'sdoor. 92 MHz (TOP and TAM series), position the jumper connection on circuit card AF43S as shown on the sheet. B The first encoding operation must be carried out whilst keeping the jumpers positioned for channels 1 and 2 as per fig. B for any subsequent settings on different channels. [. . . ] B The first encoding operation must be carried out whilst keeping the jumpers positioned for channels 1 and 2 as per fig. B for any subsequent settings on different channels. Plantear sólo el código 9 10 1 2 3 4 5 6 7 8 C vedi istruzioni su confezione see instructions on pack voir instructions sur l'emballage Siehe Anleitungen auf der Packung. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CAME C1-C2F

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CAME C1-C2F will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag