User manual CAME C1S-C2S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CAME C1S-C2S. We hope that this CAME C1S-C2S user guide will be useful to you.

Lastmanuals help download the user guide CAME C1S-C2S.


Mode d'emploi CAME C1S-C2S
Download
Manual abstract: user guide CAME C1S-C2S

Detailed instructions for use are in the User's Guide.

[. . . ] 15A fuse protects the low voltage command devices. SAFETY Photocells can be connected to obtain: - Re-opening during closure (2-C1), if the photocells identify an obstacle while the gate is closing, they will reverse the direction of movement until the gate is completely open; - Re-closing during opening (2-CX, dip 8OFF-100OFF), if the photocells identif an obstacle while the gate is openinig, they will reverse the direction of movement until the gate is copletely closed; - Partial stop, shutdown of moving gate, with activation of an automatic closing cycle (2-CX); - Total stop (1-2), shutdown of gate movement without automatic closing; a pushbutton or radio remote control must be actuated to resume movement). NB: If an NC safety contact (2-C1, 2-CX, 1-2) is opened, the LED will flash to indicate this fact. [. . . ] NB: If an NC safety contact (2-C1, 2-CX, 1-2) is opened, the LED will flash to indicate this fact. The lamp which lights the manoeuvring zone: it remains lit from the moment the doors begin to open until they are completely closed (including the time required for the automatic closure). In case automatic closure is not enabled, the lamp remains lit only during movement (E-E3); - Electric lock (11-S); ACCESORIOS CONECTABLES - Lámpara de señal de “puerta abierta” (10-5); - Lámpara ciclo. The automatic closing timer is automatically activated at the end of the opening cycle. The preset, adjustable automatic closing time is automatically interrupted by the activation of any safety system, and is deactivated after a STOP command or in case of power failure; -2 - Rilevazione di presenza ostacolo. - Obstacle presence detection: When the motor is stopped (gate is closed, open or half-open after an emergency stop command), the transmitter and the control pushbutton will be deactivated if an obstacle is detected by one of the safety devices (for example, the photocells); - Hammer movement. At every opening command, the wings press the closing stop-ledge for a second, thus facilitating the release operation of the electric lock connected to terminals 11-S. -Keep the CH1 key pressed on the base card (the signal LED will flash), and with a key on the transmitter the code is sent, the LED will remain lit to signal the successful saving of the code (figure 1); -Perform the same procedure with the CH2 key, associating it with another transmitter key (figure 2). CH1 = Channel for direct control of one function performed by the control unit on the gear motor ("open only" / "open-close-reverse" or "openstop-close-stop", depending on the position of dip switches 2 and 3). CH2 = Channel for direct control of an accessory connected across B1-B2. If you wish to change the code on your transmitters in the future, simply repeat the procedure described above. MANUFACTURER’S DECLARATION As per Enclosure II B of Machinery Directive 98/37/CE Enclosed with the technical documentation (the original copy of the Declaration is available on request) The representatives of CAME Cancelli Automatici S. It Date of the present declaration 07/12/2001 Also, they furthermore represent and warrant that the product/s that are the subject of the present Declaration are manufactured in the respect of the following main harmonized provisions: EN 292 PART 1 AND 2 EN 12453 EN 12445 EN 60335 - 1 EN 60204 - 1 EN 50081 - 1 AND 2 EN 50082 - 1 AND 2 MACHINERY SAFETY. Hereby declare, under their own respons ibility, that the product/s called . [. . . ] MANUFACTURER’S DECLARATION As per Enclosure II B of Machinery Directive 98/37/CE Enclosed with the technical documentation (the original copy of the Declaration is available on request) The representatives of CAME Cancelli Automatici S. It Date of the present declaration 07/12/2001 Also, they furthermore represent and warrant that the product/s that are the subject of the present Declaration are manufactured in the respect of the following main harmonized provisions: EN 292 PART 1 AND 2 EN 12453 EN 12445 EN 60335 - 1 EN 60204 - 1 EN 50081 - 1 AND 2 EN 50082 - 1 AND 2 MACHINERY SAFETY. Hereby declare, under their own respons ibility, that the product/s called . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CAME C1S-C2S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CAME C1S-C2S will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag