Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CANDY CMD 95. We hope that this CANDY CMD 95 user guide will be useful to you.
Lastmanuals help download the user guide CANDY CMD 95.
Detailed instructions for use are in the User's Guide.
[. . . ] Before fixing, the disposal duct for air evacuation to the outside must be installed. use an disposal duct with: minimum indispensable length; minimum possible bends (maximum angle of bend: 90°); certified material (according to the State); an as smooth as possible inside. It is also advisable to avoid any drastic changes in pipe cross-section (recommended diameter: 150 mm). For air evacuation to the outside, follow all the other instructions given on the "Warnings" sheet. [. . . ] If the height of the hood also requires adjustment, use the special regulation screws (B) (supplied). Once regulation has been completed, finish securing the hood with 2 more screws (C): mark the points for the 2 holes on the wall, remove the hood and drill (8mm diameter holes); then use the plugs and screws to complete installation. 6: The rear metal panel must be fixed to the wall in the upper part of the hob. Rest the lower edge of the panel behind the hob and fix the upper edge to the wall by means of the two holes in the panel itself, inserting the supplied screws and screw anchors (A). The appliance should be fixed to the rear panel in the same way as wall fixing, using the supplied hood brackets and the screws and screw anchors supplied with the panel (B). Fixing the telescopic flues: Using the supplied screws and screw anchors, fix the upper flue bearing bracket to the ceiling and/or wall, checking that it is aligned with the hood (Fig. Prepare the telescopic flues, remembering that their final position must be that illustrated in Fig. 8 (turn upside down the upper flue so that the air disposal gratings are downwards). connect the disposal duct to the air evacuation pipe of the hood. Use a flexible pipe and lock it to the air evacuation pipe of the hood with a metal hose clamp - Fig. Screws must be worked from the inside of appliance (Fig. For air evacuation to the outside, follow all the other instructions given on the "Warnings" sheet. Prepare the power supply within the telescopic flue (for the electrical connection, follow all the other instructions on the "Warnings" sheet). For fixing to the wall refer to the instructions for the ducting version (see point 2, 3), then continue with the instructions below. Fixing the telescopic flues: Using the supplied screws and screw anchors, fix the upper flue bearing bracket to the ceiling and/or wall, checking that it is aligned with the hood (Fig. Prepare the telescopic flues, remembering that their final position must be that illustrated in Fig. 8 (turn upside down the upper flue so that the air disposal gratings are downwards). connect the disposal duct to the air evacuation pipe of the hood. Use a flexible pipe and lock it to the air evacuation pipe of the hood with a metal hose clamp - Fig. Connect the hood to the external motor using the special terminal block (Fig. 18): remove wire clamp A and lid B from the wiring junction box; fix the connecting wire of the external motor to terminal C; then replace wire clamp A and lid B on the wiring junction box; the other end of the wire is secured to the terminal block on the external motor. Make the electrical connection by means of the power cable. [. . . ] Button C: drives the motor in second speed (the corresponding pilot lamp comes on); when pressing the button a second time (while the pilot lamp is on) , the TIMER is activated and thus the motor stops after 5' (the pilot lamp flashes). Button D: drives the motor in third speed (the corresponding pilot lamp comes on); when pressing the button a second time (while the pilot lamp is on) , the TIMER is activated and thus the motor stops after 5' (the pilot lamp flashes). Pilot lamp comes on); when pressing the button a second time (while the pilot lamp is on) , the TIMER is activated and thus the motor stops after 5' (the pilot lamp flashes). Pay special attention to the grease filters: If the model purchased has the commands shown in Figure 19: the grease filter must be cleaned periodically: exactly how often depends on use (at least once every other month). [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CANDY CMD 95
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CANDY CMD 95 will begin.