If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CANNON CANTERBURY IN-BUILT. We hope that this CANNON CANTERBURY IN-BUILT user guide will be useful to you.
Lastmanuals help download the user guide CANNON CANTERBURY IN-BUILT.
You may also download the following manuals related to this product:
CANNON CANTERBURY IN-BUILT (322 ko)
Manual abstract: user guide CANNON CANTERBURY IN-BUILT
Detailed instructions for use are in the User's Guide.
[. . . ] Cannon
CANTERBURY INBUILT MODELS
USER INSTRUCTIONS INSTALLATION INSTRUCTIONS SERVICE INSTRUCTIONS
This heater is approved for use with Natural and Propane gases. Please leave instructions with the owner
Contents
Contents Warranty Distributor Safety warnings What to do if you smell gas Warnings Standards 4-5 2 3
User instructions Operating instructions Cleaning Flame characteristics Heater specifications Installation instructions
6-8
9 10-15
Clearances Installation into a masonry/brick or mock fireplace Installation WITH a flue connected Installation WITHOUT a flue connected Sealing Gas connection 16-17 17-19
Log installation Fuel bed and log installation Gas control Gas pressure point Gas pressure adjustment Installation tips Service instructions General To replace the primary glass To replace the gas control To replace the fan To replace the electronic controller To remove the burner and electrodes To check pressures Trouble-shooting
2
19 20-21
22-24
Connections Electric wiring diagram Data plate Date installed, Compliance Certificate No. For service to this appliance
Warranty
The Cannon appliance is warranted against defects in materials and workmanship for a period of one, (1) year from its date of original purchase, for residential use in Australia. Warranty service, which includes parts and labour for the replacement or repair of defective parts, is available through the CANNON distributor. [. . . ] The rearward sloping frame must be at the top and the vertical ledge must be at the bottom. Reconnect the switch loom to the loom plug. Connect plug to the wall socket and switch it on.
Gas control
23. Gas control layout is as indicated in figure 31. Important: To achieve the correct visual flame effect: On Propane the gas pressure must be set at 2. 65 kPa with burner operating on maximum setting. On Natural Gas the gas pressure must be set at 0. 75 kPa.
Pressures for `Burner full on' and `Burner low flame' are factory set, however if pressures need to be checked or adjusted follow the procedures described below and on the next two pages.
31
To check control outlet pressure at burner `Full on" and `Low Flame" positions remove the plastic cap from the regulator adjustment location as indicated in figures 32(a & b).
32
17
Gas pressure point
24. The pressure point is closed with a captive screw. Turn screw 6 revolutions anticlockwise to open the pressure point as indicated on figure 33(a) and place manometer tube over the test point as per figure 33(b).
33a
33b
Gas pressure adjustment
25. Switch the top two control buttons to "Full On" position as indicated in figure 34(a) and using a ring spanner, as per figure 34(b), adjust the pressure to 0. 75 kPa for Natural gas or 2. 65 kPa for LPG. (Turn clockwise to increase pressure and anticlockwise to decrease pressure).
34a
34b
26. Switch the stop button back to "Low Flame' position as indicated in figure 35(a), retain spanner in position and using a screwdriver as per figure 35(b) adjust the central screw control to give a pressure reading of 0. 3 kPa for Natural Gas and 1. 1 kPa for LPG. (Turn clockwise to increase pressure and anticlockwise to decrease pressure).
35a
35a
27. Switch burners off and remove the manometer tube. Tighten pressure test point by turning the captive screw fully clockwise. Ensure the little lug is positioned towards lower right hand side to clear the control. Refit the lower front cover, making sure not to damage the power cord. Follow User Instructions to turn on heater.
18
Operate the heater on HIGH and LOW burner and all fan speeds. The flame should be stable with no lifting from the burner and the logs should glow after approximately 15 minutes of operation on HIGH burner. If the flame is unstable: · Check that the burner is located correctly. · Check that the glass front is located correctly and is against the sealing rope. · Check that the gas pressure is correctly adjusted. If the heater still does not operate to specification refer to the trouble shooting chart on pages 22 and 23 or contact Samford IXL in your state.
Installation tips
Test the operation of the chimney before installing the new heater. CANNON heaters are high efficiency products with low flue gas temperatures (typically 100°C) so if you are replacing an older type radiant heater with a much higher flue gas temperature (150°C or higher) make sure of the integrity of the fireplace and chimney before installing the new CANNON log fire. A solid, levelled and smooth base is required (fill gaps with fibreglass insulation if necessary). Avoid installing into large volume fireplaces and chimneys without any flue. Allow for the use of a flue in these applications. [. . . ] Check polarity in the electrical supply lead to appliance. · Check that the sense electrode is in the flame. · Check that appliance is earthed correctly. A check between the earth pin on the plug and an unpainted part of the appliance should see a resistance of 0. 1 ohms. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CANNON CANTERBURY IN-BUILT
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CANNON CANTERBURY IN-BUILT will begin.