User manual CANNON FITZROY PROFILE INBUILT FITZPIBPWR
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CANNON FITZROY PROFILE INBUILT FITZPIBPWR. We hope that this CANNON FITZROY PROFILE INBUILT FITZPIBPWR user guide will be useful to you.
Lastmanuals help download the user guide CANNON FITZROY PROFILE INBUILT FITZPIBPWR.
Manual abstract: user guide CANNON FITZROY PROFILE INBUILT FITZPIBPWR
Detailed instructions for use are in the User's Guide.
[. . . ] Any product subjected to misuse, abuse, negligence, accident or alteration will have its warranty voided. The defacement of serial plate will have its warranty voided. If installation is not carried out in accordance with manufacturer's instructions, this warranty may be void. The customer must keep their "Tax Invoice" as proof of purchase of this product and compliance certificate as proof of required installation. [. . . ] For `ventilation requirements' see clause 5. 4. 3.
Installation WITH a flue connected
12
11
Installation WITHOUT a flue connected
13
14
12
15
6. A 10 Amp wall socket needs to be located within 1. 5m of the heater. If using a power point in the chimney, route the plug and cord through cord access at lower LH side of rear panel. Ensure that the grommet is located over the edges of the access hole. Hard (fixed) wiring connection is to be carried out only by a qualified electrician. Remove the lower front cover by unscrewing two M5 screws from the air intake slot. If unit is fitted with supply flexible cord ensure that the cord cannot be trapped when the heater is installed. Note: if the flexible cord is damaged, disconnect from supply socket. a) Place log No. 1 onto the 2 front left pins on the burner head, ensuring that the charring faces the front. Refer figure 28.
28
b) Place log No. 2 onto the 2 left back pins. Refer figure 29.
29
c) Place log No. 3 on single right front pin, ensure fork locates over log No. Check that the gas pressure is correctly adjusted. If the heater still does not operate to specification refer to the troubleshooting chart on pages 20 & 21, or contact Sampford IXL in your state.
18
Installation tips
Test the operation of the chimney before installing the new heater. CANNON heaters are high efficiency products with low flue gas temperatures (typically 100°C) so if you are replacing an older type radiant heater with a much higher flue gas temperature (150°C or higher) make sure of the integrity of the fireplace and chimney before installing the new CANNON log fire. A solid, levelled and smooth base is required (fill gaps with fibreglass insulation if necessary). Avoid installing into large volume fireplaces and chimneys and not fitting a flue. (It is better to install a flue in these applications). We recommend cleaning or sweeping of the chimney and fireplace before the installation of the heater commences. There must be a good seal around the heater, gas piping and electrical cable rear entry to stop any leakage of combustion products. Do not use adhesives or silicone sealant, the heater must be able to be easily removed if necessary. Install a chimney plate and cowl to the chimney opening using weatherproof mortar to common building practice. Remove any curved firewall that slopes too far forward to the fireplace opening as it causes restriction to the flue path above the heater flue outlet. [. . . ] Disconnect the silicon tube from the fan pressure switch, rotate the fan scroll 90° and remove the silicon tube from the venturi located in the fan scroll. Remove the blanking piece from the fan scroll. Remove the venturi and bracket from the fan removed from the heater. Insert and secure the venturi and bracket on replacement fan. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CANNON FITZROY PROFILE INBUILT FITZPIBPWR
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CANNON FITZROY PROFILE INBUILT FITZPIBPWR will begin.