User manual CANON COLOR IMAGECLASS MF8280CW BROCHURE
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CANON COLOR IMAGECLASS MF8280CW. We hope that this CANON COLOR IMAGECLASS MF8280CW user guide will be useful to you.
Lastmanuals help download the user guide CANON COLOR IMAGECLASS MF8280CW.
You may also download the following manuals related to this product:
CANON COLOR IMAGECLASS MF8280CW DATASHEET (1654 ko)
CANON COLOR IMAGECLASS MF8280CW [MAC] IMAGECLASS MF8580CDW/MF8280CW E-MANUAL (7 ko)
CANON COLOR IMAGECLASS MF8280CW [WINDOWS] IMAGECLASS MF8580CDW/MF8280CW E-MANUAL (7 ko)
Manual abstract: user guide CANON COLOR IMAGECLASS MF8280CWBROCHURE
Detailed instructions for use are in the User's Guide.
[. . . ] - Example of Functional Execution Command: “CF_BRIGHT_032” [CR] - Example of Status Read Command: “CR_BRIGHT” [CR] Note) “_” means a space ・ When it takes more than a second to receive a single command, it is not executed. When it takes more than a second to receive carriage return (0x0D) since the reception of the first data “C”, it clears the information of the receive buffer. ・ When the command pipelining, allow the interval time of no less than100ms after receiving return value. Command PC → Projector Projector → PC “CF_BRIGHT_032” CR “000”
CR
(No less than 100 ms)
Next command
Return Value
( A few ms - 5s)
・ Do not send another command before the reception of the return value; the operation by the command is not ensured. [. . . ] “OFF” ------------------------- Set Ceiling to OFF. Set/Cancel Ceiling mode. (Available only in the normal Power ON status) The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status. Acceptable Unacceptable “000” [CR] “Error Code” [CR]
Details
Response
8. 7. 6 CF_REAR Command
Command %1 “CF_REAR_%1” [CR] “ON” --------------------------- Set Rear to ON. “OFF” ------------------------- Set Rear to OFF. Set/Cancel Rear mode (Available only in the normal Power ON status) When Rear is ON, projected image is left/right reversed. The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status. Acceptable Unacceptable “000” [CR] “Error Code” [CR]
Details
Response
32/72
COLOR IMAGECLASS MF8280CW Expand Serial Command Functional Specifications
8. 7. 7 CF_VSCALE Command
Command “CF_VSCALE_%1” [CR] “035” ---------------------- +35 “031” ---------------------- +31 : “002” ---------------------- +2 “001” ---------------------- +1 “000” ---------------------- ±0 “‐01” ---------------------‐1 “‐02” ---------------------‐2 : “‐31” ---------------------‐31 “‐32” ---------------------‐32 “UP” --------------------- Increment setting value of Vscale by 1 “DN” --------------------- Decrement setting value of Vscale by 1 Set Vscale (Available only in the normal Power ON status) *When the Aspect mode is not ”Custom”, error code “101” is returned. * When input signal is Network, error code “101” is returned. Acceptable Unacceptable “000” [CR] “Error Code” [CR]
%1
Details
Response
8. 7. 8 CF_VPOS Command
Command “CF_VPOS_%1” [CR] “015” --------------------- +15 “014” --------------------- +14 : “002” --------------------- +2 “001” --------------------- +1 “000” --------------------- ±0 “‐01” ---------------------‐1 “‐02” ---------------------‐2 : “‐14” ---------------------‐14 “‐15” ---------------------‐15 “UP” --------------------- Increment setting value of Vposition by 1 “DN” --------------------- Decrement setting value of Vposition by 1 Set V Position (Available only in the normal Power ON status) *When the Aspect mode is not ”Custom”, error code “101” is returned. * When input signal is Network, error code “101” is returned. Acceptable Unacceptable “000” [CR] “Error Code” [CR]
%1
Details
Response
33/72
COLOR IMAGECLASS MF8280CW Expand Serial Command Functional Specifications
8. 7. 9 CF_HSCALE Command
Command “CF_HSCALE_%1” [CR] “035” ---------------------- +35 “031” ---------------------- +31 : “002” ---------------------- +2 “001” ---------------------- +1 “000” ---------------------- ±0 “‐01” ---------------------‐1 “‐02” ---------------------‐2 : “‐31” ---------------------‐31 “‐32” ---------------------‐32 “UP” --------------------- Increment setting value of Hscale by 1 “DN” --------------------- Decrement setting value of Hscale by 1 Set Hscale (Available only in the normal Power ON status) *When the Aspect mode is not ”Custom”, error code “101” is returned. Acceptable Unacceptable “000” [CR] “Error Code” [CR]
%1
Details
Response
8. 10. 11 CF_RSENS Command
Command “CF_RSENS_%1” [CR] “BOTH” -------------------------------- Select both front and back receiver of projector “FRONT” ---------------------------- Select only front receiver of projector “BACK” ------------------------------------ Select only back receiver of projector “UP” --------- Switch forward (BOTH → FRONT → BACK → BOTH) “DN” --------- Switch backward (BACK → FRONT → BOTH → BACK) Select location of infrared remote receiver of remote control (Available only in the normal Power ON status) The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status. Acceptable Unacceptable “000” [CR] “Error Code” [CR]
%1
Details
Response
39/72
COLOR IMAGECLASS MF8280CW Expand Serial Command Functional Specifications
8. 10. 12 CF_P-MANE Command
Command “CF_P-MANE_%1” [CR] “OFF” ---------------------------------- Set Power Management to Off “READY” ----------------------------- Set Power Management to Ready “SHUTDOWN” --------------------- Set Power Management to Shut Down mode “UP” ----------------------- Switch forward (Off→Ready→Shut down→Off) “DN” ---------------------- Switch backward (Off→Shut down→Ready→Off) Set/Cancel Power Management (Available only in the normal Power ON status) The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status. Acceptable Unacceptable “000” [CR] “Error Code” [CR]
%1
Details
Response
8. 10. 13 CF_P-MANETIME Command
Command “CF_P-MANETIME_%1” [CR] “01” - ”30” ----------------------- Directly specify setting time by the minute “UP” ------------------------------- Increment value by 1 (Switched in 01→02→ --- → 30 → 01 order) “DN” ------------------------------ Decrement value by 1 (Switched in 30→29→ --- → 01 → 30 order) Set time of Power Management time (Available only in the normal Power ON status) The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status. Acceptable Unacceptable “000” [CR] “Error Code” [CR]
%1
Details
Response
8. 10. 14 CF_ON-STA Command
Command “CF_ON-STA_%1” [CR] “ON” --------------------------- Set Power On Start to ON. “OFF” ------------------------- Set Power On Start to OFF. “UP” ---------- Toggle between ON and OFF. (On→Off→On → - - -) “DN” --------- Toggle between ON and OFF. (On→Off→On → - - -) *”UP” and “DN” are exactly same operation. Set/Cancel Power ON Start (Available only in the normal Power ON status) The status set by this command is stored in EEPROM and setting value remains effective even after the power is turned to ALL OFF status. Acceptable Unacceptable “000” [CR] “Error Code” [CR]
%1
Details
Response
8. 10. 15 CF_POINTER Command
Command %1 “CF_POINTER_%1” [CR] “ARROW” ---------------------- Select Arrow Pointer “FINGER” ---------------------- Select Finger Pointer “LASER” ---------------------- Select Laser mark Pointer Select indication of Pointer. (Available only in the normal Power ON status) The status set by this command is stored in EEPROM and setting value remains effective even after the power is turned to ALL OFF status. Acceptable Unacceptable “000” [CR] “Error Code” [CR]
Details
Response
40/72
COLOR IMAGECLASS MF8280CW Expand Serial Command Functional Specifications
8. 10. 16 CF_KEYDIS Command
Command %1 “CF_KEYDIS_%1” [CR] “NONE” ----------------------- RC and KEY are both enabled. “RC” ---------------------------- RC is disabled. [. . . ] When the temperature is safe, all data is represented as “_00. 0S”. When the projector is reset, “_00. 0S” is set, and every time abnormal temperature occurs, it renews the data and returns it. In short, it only returns the renewed data of the latest abnormal temperature and the previous data is deleted. “?” [CR]
Response
%1, %2, %3
Unacceptable
71/72
COLOR IMAGECLASS MF8280CW Expand Serial Command Functional Specifications
9. 12. 6 CR_TEMP Command
Command Details “CR_TEMP” [CR] Get the current temperature information inside a projector. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CANON COLOR IMAGECLASS MF8280CW
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CANON COLOR IMAGECLASS MF8280CW will begin.