If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CANON REALIS SX7 MARK II. We hope that this CANON REALIS SX7 MARK II user guide will be useful to you.
Lastmanuals help download the user guide CANON REALIS SX7 MARK II.
You may also download the following manuals related to this product:
CANON REALIS SX7 MARK II (6359 ko)
CANON REALIS SX7 MARK II COMMANDS (2367 ko)
CANON REALIS SX7 MARK II REALIS-PRO-AV_LINE-DRAWING.PDF (1569 ko)
Manual abstract: user guide CANON REALIS SX7 MARK IIBROCHURE
Detailed instructions for use are in the User's Guide.
[. . . ] Version number of User Commands changed to "01. 0100. " Entire document Listing of the parameters for each command changed to the listing obtained by the "RANGE" command. Entire document "Character interval timeout" in communication specifications changed from 10ms to 5 seconds (timeout PAGE 2 between CR and LF is 10ms). "GUID" in "User Command System" changed to "GUIDE. " PAGE 8 PAGE 12 "GUID" in "Command List" changed to "GUIDE. Condition added to "RC/MAIN commands" as a condition for returning from power management standby PAGE 11 in "Power Management Mode. " "AUTOSETEXE" command changed from a "setting" command to a "control" command. [. . . ] In the case of any other commands, "i:BUSY (ZOOM)" is returned unconditionally, and zoom drive continues. REMOTE LOCAL POWER ZCONTDRV=STOP
(5) The following commands are acknowledged during zoom drive, and a response is returned while the drive continues. GET GET GET GET MODE POWER ERR LAMPCOUNTER e. GET PRODCODE GET ROMVER GET COMVER
(6) Zoom drive stops when the "POWER" button on the remote control or main unit panel is pressed during zoom drive. Example Control > ZCONTDRV=TELE < I:OK Range acquisition > RANGE ZCONTDRV < r:ZCONTDRV = I, STOP, WIDE, TELE
Control over the zooming to the telephoto end is started.
"STOP, " "WIDE" or "TELE" can be set for zoom lens continuous drive.
Commands supported
SX50 SX6 SX60 X600 ** ** ** ** × When a command is not supported, "e:0002 INVALID_COMMAND" is returned.
Supported Command States
Model Power supply
OFF ON PM
D-RGB A-RGB1 A-RGB2
Comp
Input Video
S-Video D-Video SCART
None
Mode Remote Local ×
Remarks
SX50 SX6 SX60 X600
××
*If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. *When the power supply state is in the process of switching, an "i:BUSY" reply may be sent.
PAGE 66
User Command Specifications
Details of command FSTEPDRV
1
FSTEPDRV
Commands
FSTEPDRV
FSTEPDRV=<Focus lens step control parameter>
Mode Control Setting
Reference
Function Focus lens step drive control Format
Parameter Focus lens step control parameters Parameter Meaning FAR This initiates focusing toward the far end. NEAR This initiates focusing toward the near end. The parameters which can be set at any given point in time can be obtained using the RANGE command. For details, refer to the RANGE command. Response "i:OK" is returned when zooming was completed successfully after step drive. For all other responses, refer to "Error List. " Description This command is used to drive the focus lens. GET GET GET GET MODE POWER ERR LAMPCOUNTER e. GET PRODCODE GET ROMVER GET COMVER
(6) Focus drive stops when the "POWER" button on the remote control or main unit panel is pressed during focus drive. Example Control > FCONTDRV=NEAR < I:OK Range acquisition > RANGE FCONTDRV < r:FCONTDRV=I, STOP, FAR, NEAR
Control over the focusing to the near end is started.
"STOP, " "FAR" or "NEAR" can be set for focus lens continuous drive.
Commands supported
SX50 SX6 SX60 X600 ** ** ** ** × When a command is not supported, "e:0002 INVALID_COMMAND" is returned.
Supported Command States
Model Power supply
OFF ON PM
D-RGB A-RGB1 A-RGB2
Comp
Input Video
S-Video D-Video SCART
None
Mode Remote Local ×
Remarks
SX50 SX6 SX60 X600
××
*If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. *When the power supply state is in the process of switching, an "i:BUSY" reply may be sent.
PAGE 68
User Command Specifications
9. Details of command RC
2
RC
Commands
RC
RC<Remote control emulation button parameters>
Mode Control Setting Reference
Function Remote control operation emulate Format
Parameter Remote control emulation button parameters The key assignment for the remote control emulation buttons is as follows. Remote control button POWER MENU AUTO SET COMPUTER1 COMPUTER2 VIDEO INPUT AUTOPC KEYSTONE UP DOWN LEFT RIGHT OK R_CLICK PAGE PAGE IMAGE FREEZE VOL + VOL VOL NOSHOW MUTE P-TIMER DZOOM + DZOOM_M SPOT FOCUS ZOOM Parameter POWER POWER_OFF MENU AUTOSET COMPUTER1 COMPUTER2 VIDEO INPUT AUTOPC KEYSTONE UP UP+REP DOWN DOWN+REP LEFT LEFT+REP RIGHT RIGHT+REP OK R_CLICK P_UP P_UP+REP P_DOWN P_DOWN+REP IMAGE FREEZE VOL_P VOL_M VOL NOSHOW MUTE P_TIMER DZOOM_P DZOOM_P+REP DZOOM_M DZOOM_M+REP SPOT FOCUS ZOOM *-REP
Errors supported by model SX50 SX6 SX60 X600
Remarks
POWER button pressed twice
× × × × × × × × × × × × × ×
× × × × ×
× × × × ×
× × × × ×
Button press start Button press start Button press start Button press start
ID
Button press start Button press start
Button press start Button press start
Button press end
*Use the application to adjust the time between pressing of keys.
PAGE 69
User Command Specifications
9. Details of command RC
Response "i:OK" is returned when the button press request has been acknowledged successfully. (It does not indicate if the operation for the pressed button was executed properly. ) Description This emulates pressing of the remote control buttons for controlling the projector. -1 It can only be used during Local mode. Note 1 With the emulation of the remote control operations, the functions of the buttons corresponding to the parameters cannot necessarily be executed. Emulation simply consists in emulating the pressing of the buttons. [. . . ] A communication protocol violation occurred in the projector. This cannot be executed with the current input source. The current input source is indicated in parentheses. This cannot be executed with the current input signal. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CANON REALIS SX7 MARK II
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CANON REALIS SX7 MARK II will begin.