User manual CARLO GAVAZZI EDM 35 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CARLO GAVAZZI EDM 35. We hope that this CARLO GAVAZZI EDM 35 user guide will be useful to you.

Lastmanuals help download the user guide CARLO GAVAZZI EDM 35.


Mode d'emploi CARLO GAVAZZI EDM 35
Download
Manual abstract: user guide CARLO GAVAZZI EDM 35DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Introduction 1. 1 Getting Started 1. 2 Overall Description 1. 3 Features 1. 4 Block Schematic 2. Unit Description 2. 1 Modules 2. 2 Main Unit 3. Installation & Operations before Use 3. 1 Procedure 3. 2 Installation 3. 3 Rated Operational Voltage 3. 4 Jumper Setting on Modules 3. 5 Input Range Selection 4. Operation & Programming 4. 1 Switching On 4. 2 Operating Modes 4. 3 Programming 5. [. . . ] If the entered password matches the stored password, the instrument automatically proceeds to the next step - otherwise it returns to measurement and control mode. 20 4. 3 Programming 4. 3. 1 New Password 1. After you have entered the password the display shows the present value, press S . After 2 s the stored value of the password is displayed. To retain to pass on to the next selection. To modify the password, press v and/or w until the desired value is displayed; this has to be a number between 0 and 199. Press S to pass on to the next parameter. A password between 100 and 199 gives direct access to setpoint programming in the following way: Enter programming mode and press `S'. Then you will automatically jump directly to setpoint programming. After the setpoint programming the programming mode is terminated. 4. 3. 2 Decimal Point Selection Decimal point selection is relative to the displayed value. After selection of the password the display will show display by a steady light as . for 2 s. The current position of the decimal point is then indicated on the 2. Change the position of the decimal point using v (shift to left) and/or w (shift to right). Press S to enter and pass on to next. 4. 3. 3 Electrical Input Range (HiE and LoE) This feature allows you to define an electrical input range different from the standard range. For example, for EDM with full-scale 20 mA (±19. 99 mA), it is possible to select an electrical input range from 4. 00 mA to 19. 99 mA by proceeding as follows: 1. After programming the decimal point the display shows seconds signifying the maximum of the electrical input range. The HiE value stored in the memory is shown on the display, for example . To retain the value shown, press for 2 21 ENGLISH 2. To select a new value of HiE, press v and/or w until the desired ENGLISH value is displayed, for example . After programming the HiE the display shows signifying the minimum of the electrical input range. The LoE value stored in the memory is then shown on the display. To modify the LoE value proceed as described for the HiE value, but select the value 4. 00 (according to the example). Press S to accept the value and pass on to the next parameter. Note!LoE and HiE values are shown in the same unit of measurement as the input module range. 4. 3. 4 Display Span (Hi and Lo) This allows you to define the display span (in engineering units) corresponding to the previously defined electrical input range. [. . . ] overload ( 10 s) 20 mA 100 mA 200 mA 500 mA 4A 8A Scaling Values Code (EDM) A1D A2D A3D A4D A5D A6D Range ±199. 9 µA ±1. 999 mA ±19. 99 mA ±199. 9 mA ±1999 mA ±5 A DP 111. 1 1. 111 11. 11 111. 1 1111 11. 11 HiE 199. 9 1. 999 19. 99 199. 9 1999 19. 99 LoE -199. 9 -1. 999 -19. 99 -199. 9 -1999 -19. 99 Hi 199. 9 1. 999 19. 99 199. 9 1999 5. 00 Lo -199. 9 -1. 999 -19. 99 -199. 9 -1999 -5. 00 A6D is the default range set from factory. 7. 2. 4 AC Ammeter (5100533 and 5100633) Specifications Code (EDM) A1A A2A A3A A4A A5A A6A Range 199. 9 µA 1. 999 mA 19. 99 mA 199. 9 mA 1999 mA 5. 00 A Resolution 0. 1 µA 1 µA 10 µA 0. 1 mA 1 mA 10 mA 0. 5% ± 3 dgt ±200 ppm/°C ±0. 5 dgt/°C 0. 3% ± 3 dgt ±150 ppm/°C ±0. 5 dgt/°C < 200 mV Accuracy Temperature drift Voltage drop Max. overload ( 10 s) 20 mA 100 mA 200 mA 500 mA 4A 8A Scaling Values Code (EDM) A1A A2A A3A A4A A5A A6A Range 199. 9 µA 1. 999 mA 19. 99 mA 199. 9 mA 1999 mA 5A DP 111. 1 1. 111 11. 11 111. 1 1111 11. 11 HiE 199. 9 1. 999 19. 99 199. 9 1999 19. 99 LoE -0. 1 -0. 001 -0. 01 -0. 1 -1 -0. 04 Hi 199. 9 1. 999 19. 99 199. 9 1999 5. 00 Lo -0. 1 -0. 001 -0. 01 -0. 1 -1 -0. 01 A6A is the default range set from factory. 36 7. 2. 5 10 A AC/DC Ammeter (5100534 and 5100634) Specifications Code (EDM) A7A A7D Range 10 A AC 10 mA ±10 A DC 0. 5% ± 5 dgt Resolution Accuracy 0. 5% ± 5 dgt Temperature drift ±200 ppm/°C ±0. 5 dgt/°C ±200 ppm/°C ±0. 1 dgt/°C Voltage drop Max. overload ( 10 s) < 200 mV 12 A Scaling Values Code (EDM) A7A A7D Range 10 A AC ±10 A DC DP HiE LoE -0. 2 -19. 99 Hi Lo -0. 01 -10. 00 A7A is the default range set from factory. 11. 11 19. 99 10 7. 2. 6 Ohmmeter (5100535 and 5100635) Specifications Code (EDM) R1D R2D R3D R4D Range 199. 9 1. 999 k 19. 99 k 199. 9 k Resolution 0. 1 1 0. 01 k 0. 1 k 0. 2% ± 2 dgt ±150 ppm/°C ±0. 1 dgt/°C 6 VDC Accuracy Temperature Open cirdrift cuit voltage Excitation current 1 mA 100 µA 10 µA 1 µA Scaling Values Code (EDM) R1D R2D R3D R4D Range 199. 9 1. 999 k 19. 99 k 199. 9 k DP 111. 1 1. 111 11. 11 111. 1 HiE 199. 9 1. 999 19. 99 199. 9 LoE -0. 1 -0. 001 -0. 01 -0. 1 Hi 199. 9 1. 999 19. 99 199. 9 Lo -0. 1 -0. 001 -0. 01 -0. 1 R1D is the default range set from factory. 7. 2. 7 Pt 100 Thermometer (5100536 and 5100636) Specifications Code (EDM) P1C RTD Pt 100 P1F P2F = 0. 00385 -148. 0 to 199. 9°F -148. 0 to 392°F 0. 2°F 1°F Sensor type Range -100. 0 to 199. 9°C Resolution 0. 1°C Accuracy 0. 2% of rdg ±2 dgt 0. 4% of rdg ±4 dgt 0. 2% of rdg ±4 dgt Temperature drift ±150 ppm/°C ±0. 05 count/°C ±180 ppm/°F ±0. 1 count/°F 37 ENGLISH 7. 2. 7 Pt 100 Thermometer (5100536 and 5100636) - continued ENGLISH Scaling Values Code (EDM) P1C P1F P2F Range -100. 0 to 199. 9°C -148. 0 to 199. 9°F -148. 0 to 392°F DP HiE 199. 9 93. 2 1999 LoE Hi Lo -100. 0 -148. 0 -148 P1C is the default range set from factory. 111. 1 1111 -100. 0 -100 199. 9 392 7. 2. 8 Pt 100 850°C Thermometer (5100539 and 5100639) Specifications Code (EDM) P2C P3F Sensor type RTD Pt 100 = 0. 00385 Range -100 to 850°C -148 to 1562°F Resolution 1°C 2°F Accuracy 0. 2% of rdg ±3 dgt 0. 4% of rdg ±6 dgt Temperature drift ±150 ppm/°C ±0. 05 count/°C ±180 ppm/°F ±0. 1 count/°F Scaling Values Code (EDM) P2C P3F Range -100 to 850°C -148 to 1562°F DP HiE LoE Hi 850 1562 Lo -100 -148 P2C is the default range set from factory. 1111 1999 -235 7. 2. 9 Thermocouple Type J Thermometer (5100537 and 5100637) Specifications Code (EDM) -JC -JF Sensor type Thermocouple Type J Range -100 to 760°C -148 to 1400°F Resolution 1°C 2°F Accuracy 0. 1% of rdg ±4 dgt 0. 1% of rdg ±8 dgt Temperature drift ±100 ppm/°C ±0. 05 count/°C ±180 ppm/°F ±0. 1 count/°F Scaling Values Code (EDM) -JC -JF Range -100 to 760°C -148 to 1400°F DP HiE LoE Hi 760 1400 Lo -100 -148 -JC is the default range set from factory. 1111 1999 -264 38 7. 2. 10 Thermocouple Type K Thermometer (5100538 and 5100638) Specifications Code (EDM) -KC -KF Sensor type Thermocouple Type K Range -100 to 1250°C -148 to 1999°F Resolution 1°C 2°F Accuracy 3% of rdg ±3 dgt 4% of rdg ±5 dgt Temperature drift ±100 ppm/°C ±0. 05 count/°C ±180 ppm/°F ±0. 1 count/°F Scaling Values Code (EDM) -KC -KF Range -100 to1250°C -148 to 1999°F DP HiE 1999 1748 LoE Hi 1250 1999 Lo -100 -148 -KC is the default range set from factory. 1111 -160 Accuracy for Sub-ranges Code (EDM) Sensor type Range -100 to -50°C -KC Thermocouple Type K -50 to 780°C 780 to 1250°C -148 to -58°F -KF Thermocouple Type K 1436 to 1999°F -58 to 1436°F 2°F 1°C Resolution Accuracy 1% of rdg +5/-1 dgt 0. 1% of rdg ±3 dgt 0. 25% of rdg +1/-3 dgt 1% of rdg +10/-2 dgt 0. 1% of rdg ±5 dgt 0. 25% of rdg +2/-6 dgt ±180 ppm/°F ±0. 1 count/°F ±100 ppm/°C ±0. 05 count/°C Temperature drift 7. 2. 11 Frequency Meter (5100541 and 5100 641) Specifications Code (EDM) F1x F2x Range 5. 0 to 199. 9 Hz 10 to 1999 Hz Resolution 0. 1 Hz 1 Hz Accuracy Temperature drift Input Input imp. 1 k 5 k 600 k Namur 1% of reading ± 200 ppm/ºC NPN, PNP, contact ±5 dgt 600 VAC Scaling Values Code (EDM) F1x F2x Range 5. 0 to 199. 9 Hz 10 to 1999 Hz DP 111. 1 1111 HiE 199. 9 1999 LoE 5. 0 10 Hi 199. 9 1999 Lo 5. 0 10 F2B is the default range set from factory. Connections: Namur: Vout sensor (+), IMP INPUT (-) NPN, PNP, Contact: IMP INPUT and IN LO AC voltages: 600 VAC and IN LO 39 ENGLISH 7. 2. 12 Tachometer (5100540 and 5100 640) ENGLISH Specifications Code (EDM) T1A T1B T2A T2B T3A T3B T4A T4B T5A T5B T6A T6B Range 8. 0 to 199. 9 rpm, 30 ppr 8. 0 to 199. 9 rpm, 30 ppr 5. 0 to 199. 9 rpm, 60 ppr 5. 0 to 199. 9 rpm, 60 ppr 3. 0 to 199. 9 rpm, 100 ppr 3. 0 to 199. 9 rpm, 100 ppr 20 to 1999 rpm, 30 ppr 20 to 1999 rpm, 30 ppr 10 to 1999 rpm, 60 ppr 10 to 1999 rpm, 60 ppr 10 to 1999 rpm, 100 ppr 10 to 1999 rpm, 100 ppr 1 rpm 1% of rea- ± 200 ppm/ºC ding ±5 dgt 0. 1 rpm Resolution Accuracy Temperature drift Input/Input impedance Namur / 1 k NPN, PNP, contact / 5 k Namur / 1 k NPN, PNP, contact / 5 k Namur / 1 k NPN, PNP, contact / 5 k Namur / 1 k NPN, PNP, contact / 5 k Namur / 1 k NPN, PNP, contact / 5 k Namur / 1 k NPN, PNP, contact / 5 k Scaling Values Code (EDM) T1x T2x T3x T4x T5x T6x Range 8. 0 to 199. 9 rpm, 30 ppr 5. 0 to 199. 9 rpm, 60 ppr 2. 0 to 199. 9 rpm, 100 ppr 20 to 1999 rpm, 30 ppr 10 to 1999 rpm, 60 ppr 10 to 1999 rpm, 100 ppr DP 111. 1 111. 1 111. 1 1111 1111 1111 HiE 199. 9 199. 9 199. 9 1999 1999 1999 LoE 8. 0 5. 0 2. 0 20 10 10 Hi 199. 9 199. 9 199. 9 1999 1999 1999 Lo 8. 0 5. 0 2. 0 20 10 10 T6B is the default range set from factory. Connections: Namur: Vout Namur (+), IMP INPUT (-) NPN, PNP, Contact: IMP INPUT, Vout NPN/PNP and IN LO 7. 2. 13 Dupline® Analink Interface Module (G 2139 1139) Scaling Values Code (EDM) DP 111. 1 HiE 1999 LoE 0 Hi 60. 0 [°C] Lo -30. 0 [°C] The values shown are factory settings. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CARLO GAVAZZI EDM 35

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CARLO GAVAZZI EDM 35 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag