User manual CARLO GAVAZZI RAD CONFIGURATION

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CARLO GAVAZZI RAD. We hope that this CARLO GAVAZZI RAD user guide will be useful to you.

Lastmanuals help download the user guide CARLO GAVAZZI RAD.


Mode d'emploi CARLO GAVAZZI RAD
Download
Manual abstract: user guide CARLO GAVAZZI RADCONFIGURATION

Detailed instructions for use are in the User's Guide.

[. . . ] 20 M ot i on R a d a r S e n s o r R A D S e ri e s Motion Radar Sensor is a digital uni or bidirectional motion sensor for trouble-free opening of all types of automatic doors (sliding, swinging, folding, revolving, speed-doors, overhead doors, etc. . . ), for pedestrian and civil applications. It can be adapted to every application without further accessories and can be controlled by an infrared remote controller. Mounting height up to 4m (13. 12ft) also available in uni- or bidirectional mode to detect motion towards or away from the device. Like most of other microwave detectors, equipped with planar flat antenna, Carlo Gavazzi Radar activates automatic doors utilizing doppler shift effect for detecting movements. EXIT After installation from the front side, insert the screwdriver in the provided slot. [. . . ] to end setting procedure. IR remote controller setting procedure Please refer to the following tables in order to modify radar parameters setting with remote controller. All changes made by remote controller, except (OPEN, CLOSE and AUTO), are stored into the radar memory and reloaded during radar restart. 11 O PE N Relay hold time Uni-bidirectional mode Immunity detection PROGRAMMING PROCEDURE START UP Press together Green LED DEC & INC per 1 switch on sec. permanently. 9 R AD -0 0R C AU TO D C OO LO R SE 10 1 0 4 5 X X X X 0* F 7 SE N S 3 2 8 9 5 6 TIM E 1 7 2 16 12 IM M Q P + - SENSITIVITY X X Press together Red LED DEC & INC per 1 flash once. sec. Return to Step 2 or press DEC & INC will Press DEC or INC per 1 sec. to increase Red LED flashes the number of the new per 1 sec. to go to Hold Time (see Hold or decrease Sensitivity current value. to end setting procedure. 6 4 SE N S TIM E PIN - + 15 8 14 3 13 * Not available RED GREEN LED LED RESPONSE RESPONSE RED GREEN LED LED RESPONSE RESPONSE Factory Default Value The device is set up in factory at the following default values: 1. PIN security: At the first start up, the device loads the default values. HOLD TIME 10 (max level) 1 (min: 0. 5 sec) Bi-directional (Uni-directional mode is available only for RAD 02) Immunity: OFF ; Quasi-Presence: OFF Passive 0000 - block disabled (only for remote controller) DETECTION MODE X X X X Return to Step 2 or press DEC & INC Press together Red LED will Press DEC or INC per 1 sec. to increase Red LED flashes the number of the new per 1 sec. to go to Detection Mode DEC & INC per 1 or decrease Hold Time current value set value (1. . . 10 quick flashes). (see Detection Mode STEP 1) or wait sec. to end setting procedure. KEY FUNCTION KEY FUNCTION 1 0. . . 9 9 Numerical keys NONE NONE OPEN Programming procedure Radar set value can be modified through the two buttons on the main PC board (On Board setting procedure) or with the IR remote controller [optional] (IR remote controller setting). When the two buttons are released the Green LED states permanently active (ON) so the device is ready to be set. Next setting action must be done in 20 seconds, otherwise the device return in normal operation mode and it's necessary to restart. 1 quick flash: Relay mode PASSIVE Press together Red LED will Press INC per 1 sec. to change Relays (NO); DEC & INC per 1 flash five times. Status current value 2 quick flashes: Relay mode ACTIVE sec. (NC); Return to Step 2 or press DEC & INC per 1 sec. to go to Restore (see Restore STEP 1) or wait 20 sec. to end setting procedure. TIME + Press "TIME +" key to increase Hold Time set 1. . . 10 flash NONE quick value. 6 SENS - RELAY STATUS X X Press "SENS -" key to 1. . . 10 decrease Sensitivity set quick flash NONE value. 7 SENS + Press "SENS +" key to 1. . . 10 increase Sensitivity quick flash NONE value. Press "PIN" key to change 4-number PIN (It's necessary to insert See next NONE the user PIN code if it's table different from Factory Default Value). RESTORE X X Press together 1 quick flash: Restore PIN to 0000 Red LED will Press INC per 1 sec. [. . . ] RED LED ANSWER X Red LED will flash twice if PIN code is OK: get to Step 3. No flash will happen if PIN code is not correct: restart from Step 1. STEP 3 USER'S ACTION Actual PIN code = 0000 Not (Factory set available. value) Compose sequentially the Actual PIN actual XXXX Press once code = xxxx Red LED will code value with "UNLOCK" (User set flash once. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CARLO GAVAZZI RAD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CARLO GAVAZZI RAD will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag