User manual CARLO GAVAZZI WM14-96 PROGRAMMING

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CARLO GAVAZZI WM14-96. We hope that this CARLO GAVAZZI WM14-96 user guide will be useful to you.

Lastmanuals help download the user guide CARLO GAVAZZI WM14-96.


Mode d'emploi CARLO GAVAZZI WM14-96
Download
Manual abstract: user guide CARLO GAVAZZI WM14-96PROGRAMMING

Detailed instructions for use are in the User's Guide.

[. . . ] Insulation: AC power supply, 4kV for 60s between measuring input and power supply and between power supply and RS485, 500V for 60s between measuring input and RS485. Input and power supply and between power supply and RS485. Line termination: by means of external jumper. Digital outputs (only with PG option): number of outputs 2 (one for kWh one for kvarh) Number of pulses: from 0. [. . . ] i THE MAIN MENU FUNCTIONS n_P : new password , change password function. SYS : electrical system, choose the correct electrical system; 3P. I: 3-phase balanced with or without neutral (requires only one voltage input "VL1-N" and one current input "I1)"; 2P: twophase, 1P: single phase. Example: if the primary of the CT being connected is 300kA and the secondary is 5A, the CT ratio corresponds to 60, 0k (obtained from the calculation: 300000/5). : integration time for the calculation of power dmd: select the required value from 1 to 30 minutes. End : to confirm the new selected values press the S key, or press L M to remain in the programming menu. 2 : setup of output 1 / 2, select: EnE : retransmits the value of the active energy "Act" or the reactive one "rEA" by means of pulses. "dP" selects the decimal point. "PuL" selects the number of pulses per kWh/kvarh from 0, 01 to 500. No, to go straight to the settings of the next alarm. YES, to continue the programming of all other parameters relating to the alarm being set: d. TYP : select the alarm type: up (uP) or down (do), in window alarm (in), out window alarm (out). Fun : select the OR or AND function (see the "OR/AND" picture below) out : select the relay to be enabled in case of alarm. The measured variable blinks when an alarm occurs (see figure "G" on the left: VL1, 200V). It's possible to link more than one alarm to the same variable, the first alarm condition will make the variable range blink. the "al" (· ) LED shows the activation of one of the two outputs (relay or open collector output) in case they are selected as alarm. When both digital outputs are installed in the instrument (relay or open collector), it's possible to manage up to 16 alarms that can be linked to output 1 and/or output 2. If "var" or "W are negative, the decimal point on the very right blinks in correspondence with the negative variable (see figure "H" on the left). If the instrument displays a negative power, the relevant energy will not be counted. i SAFETY PRECAUTIONS Carefully read the instruction manual. If the instrument is used in a way which is not specified by the builder, the protection may be impaired. Maintenance: To keep the intrument clean, use a damp cloth; do not use abrasives or solvents. [. . . ] Insulation by means of optocuplers, 4000 VRMS output to measuring inputs, 4000 VRMS output to power supply input. Insulation: (for 1 minute) 4kVACRMS between measuring inputs and power supply. [1]- 1 phase 2-wire connection, 1 CT [2]- 2-phase, 3-wire connection, 2 CT's [3]- 3-phase, 3-wire connection, ARON [4]- 3-phase, 3-wire connection, ARON and 2 VT's [5]- 3-phase, 4-wire connection, unbalanced load, 3 CT's [6]- 3-phase, 4-wire connection, unbalanced load, 3 CT's and 3 VT [7]- 3-phase, 3-wire connection, unbalanced load, 3 CT [8]- 3-phase, 3-wire connection, unbalanced load, 3 CT and 2 VT [9]- 3-phase, 3-wire connection, balanced load, 1 CT [10]- 3-phase, 4-wire connection, balanced load, 1 CT and 1 VT [11]- 3-phase, 4-wire connection, balanced load, 1 CT [12]- Power supply connection. Fuse value F: power supply L from 18 to 60 VAC/DC = 630mA. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CARLO GAVAZZI WM14-96

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CARLO GAVAZZI WM14-96 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag