If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CARLO GAVAZZI WM3-96. We hope that this CARLO GAVAZZI WM3-96 user guide will be useful to you.
Lastmanuals help download the user guide CARLO GAVAZZI WM3-96.
Manual abstract: user guide CARLO GAVAZZI WM3-96PROGRAMMING
Detailed instructions for use are in the User's Guide.
[. . . ] 2
Index
CARLO GAVAZZI WM3-96
FW rev. 12
32bit µ-Processor based power quality analyser with modular housing for Plug and Play modules
Instruction manual: INDEX
TO BEGIN WITH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 s The main programming parameters . . . . . . . . . . . . . . . . . . . . . . . . . . 5 s Front panel description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Select DUAL TARIFF from the energy meters menu by means of the and keys and confirm with . Select WHOLE YEAR and confirm with to enter the relevant menu; now you can enter the programming of the daily period as follows: 1- press : the first box (trf=tariff) is highlighted; 2- press again: the TARIFF box will appear on the lower part of the display; now you can choose the tariff (from 1 to 4, e. g. : 1) by means of the and keys;
v
17
Min/Max values
Energy Meters Management
28
24
v
Energy Meters Management
23
1. 2. . . . 2. 1
Proceed with the same principle for the following rows. Diagrams
3- press the key again; the "endtariff" hour is highlighted; 4- press the key again; the HOURS box will appear on the lower part of the display; now you can choose the hours - e. g. 5- press the key again; the "end tariff" minutes will be highlighted; 6-press the key again: the MINUTES box will appear on the lower part of the display; now you can set the minutes - e. g. 7-after the confirmation of the last setting, press and you are back to the selection of the first "trf" parameter you have highlighted. The "starting hour" of the following line becomes equal to the "end hour" you have just selected. Only when the "trf" parameter is highlighted, you can scroll the parameters and modify them: use the key to access to the key to move parameter; use the from left to right and the key to move from right to left. 8- Press to exit the programming of the parameters of the relevant row (no boxes are to be highlighted); 9- press and to select one of the other programming lines; the pointer on the right shows the line where the user can modify the parameters (points from 1 to 7).
Reset of the energy meters
v
21
22
28
28
v
24
Energy Meters Management
a) the day can be divided into up to 8 different periods connected to up to 4 different tariffs according to the following working principle:
20 18 16
22
24
2 4 6 8
trf1
14
12
10
+ kWh - kWh + kvarh - kvarh
1
Imported active energy Exported active energy Imported reactive energy Exported reactive energy
The measured energy (partial energy) is placed in TARIFF 1 when the time period is from midnight to e. g. 8:00am, in TARIFF 2 when the time period is from 8:00a. m. and again in TARIFF1 when the time period is from 08:00p. m. The total measured energy is the result of the sum of all the partial measures as shown in the figure below:
+ kWh - kWh + kvarh - kvarh + kWh - kWh + kvarh - kvarh
1
trf1
20 18 16
22
24
2 4 6 8
trf1
14
+ kWh - kWh + kvarh - kvarh
T
12
10
trf2
2
b) the starting point of the first time period is always 24:00 (midnight) and cannot be changed; c) the starting point of the following period is always the end hour of the previous time period; d) the daily loop is closed by setting 24:00 as last hour of the last time period (to follow this procedure see point 4 on the previous page), confirm the setting by pressing and to go back to the TARIFF SELECTION menu.
v
19
Average power calculation
Trf holiday period
22
28
26
v
Energy Meters Management
25
PROGRAMMING THE HOLIDAY PERIOD
To program the HOLIDAY period, proceed in the following way. 10- Choose HOLIDAY in the SEASON menu by means of the and keys and confirm with : the HOLIDAY menu will be displayed (see figure on the left); 11-press : the month corresponding to the start date will be highlighted; 12-press : the box for setting the month will be enabled; and to select the 13-use desired month (from 1 to 12); 14-press the key to confirm the selection and move to the next parameter: day setting; 15-press the key again to open the box where the day is to be set; 16-use the and keys to select the desired day (from 1 to 31 depending on the previously selected month); 17-press the key to confirm the selection and move to the next parameter.
1. 2. . . . 2. 1
On page 26 To reset, press
.
v
23
Dual tariff management
Display of harmonics
21
28
29
v
26
Energy Meters Management
To program the "end date" follow the same procedure described above from No. After confirming the "end" day by means of the key, the HOLIDAY box is highlighted to indicate the conclusion of the HOLIDAY period programming cycle. You can also use the (moves from right to left) and (moves from left to right) keys to scroll along the available parameters. It's possible to choose the tariff to be associated to the HOLIDAY period according to the following procedure: From page 25 starting from the box on the previous page, number 10, press the key again: the instrument will display the box shown on the left. Press : the box of the "trf" value is highlighted; key again: the instrupress the ment will display on the lower section the box where the tariff is to be set. Select the desired tariff (from 1 to 4) by means of the and keys and confirm it with . To reset your choices and/or exit the menus, use the key.
pag. . . 2. 1
Diagrams
Meters reset
v
21
22
28
28
v
Energy Meters Management
MULTI TARIFF
27
This function allows the management of the meters according to many periods per day and three periods per year: WINTER, SUMMER and HOLIDAY. To program the parameters relating to the winter season, simply follow the same procedure (holidays) described on page 25 from No. [. . . ] PULSE OUTPUT: (on request) · Number of outputs: up to 4 (on request) · Type: 1 to 1000 programmable pulses for k-M-G Wh, k-M-G varh, open collector (NPN transistor) · VON 1. 2VDC / max. · Pulse duration: 220ms (ON), 220ms (OFF) according to DIN43864. · Insulation: by means of optocouplers, 4000 Vrms output to measuring inputs, 4000 Vrms output to power supply inputs · Note: the outputs can be either open collector type or relay type (for this latter one see the characteristics mentioned in the ALARMS).
Single- phase Connection
v
55
Harmonic Analysis
56
64
62
v
Technical features
61
ALARMS: (on request) · Number of outputs: up to four, independent · Alarm type: up alarm, down alarm, up alarm with latch, down alarm with latch, phase asymmetry, phase loss, neutral loss. · Set-point adjustment: 0 to 100% of the electrical scale · Hysteresis: 0 to 100% of the electrical scale · On time delay: 0 to 255s · Relay status: selectable, normally close or normally open. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CARLO GAVAZZI WM3-96
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.