User manual CARRIER 23422-PSD-09-2003

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CARRIER 23422-PSD-09-2003. We hope that this CARRIER 23422-PSD-09-2003 user guide will be useful to you.

Lastmanuals help download the user guide CARRIER 23422-PSD-09-2003.


Mode d'emploi CARRIER 23422-PSD-09-2003
Download
Manual abstract: user guide CARRIER 23422-PSD-09-2003

Detailed instructions for use are in the User's Guide.

[. . . ] Pompe à chaleur air / eau avec module hydraulique intégré AQUASNAP 30RH 040-240 «B» Puissance calorifique nominale 39 - 229 kW Puissance frigorifique nominale 38 - 210 kW Les pompes à chaleur Aquasnap 30RH utilisent les dernières avancées technologiques: fluide frigorigène écologique HFC-407C, compresseurs Scroll, ventilateurs bas niveau sonore en matériau composite, régulation par microprocesseur. Le circuit frigorifique avec son réservoir/ échangeur breveté et le système de régulation auto-adaptatif Pro-Dialog garantissent un fonctionnement fiable et économique sous tous les climats de -10°C à +45°C. Aquasnap est équipé en standard d'un module hydraulique complet limitant l'installation à de simples opérations de câblage électrique, et de raccordement des tuyauteries de départ et de retour d'eau. Caractéristiques I Module hydraulique intégré pour une installation rapide. [. . . ] Les conditions de fonctionnement des unités 30RH sont décrites ci-dessous: · Environnement* - La classification de l'environnement est décrite dans la norme EN 60721 (équivalent à CEI 60 721): - installation à l'extérieur*, - gamme de température ambiante: - 10°C à + 45°C +/- 1°C selon l'unité, classification 4K3*, - altitude: 2000 m, - présence de corps solides: classification 4S2 (présence de poussières non significatives)*, - présence de substances corrosives et polluantes, classification 4C2 (négligeable), - vibrations, chocs: classification 4M2. · Compétence des personnes: classification BA4* (personnel qualifié - CEI 60364). Variations de fréquence de l'alimentation puissance: ± 2 Hz. Le conducteur Neutre (N) ne doit pas être connecté directement à l'unité (utilisation de transformateurs si nécessaire. ) 4. La protection contre les surintensités des conducteurs d'alimentation n'est pas fournie avec l'unité. Le ou les interrupteurs - sectionneurs montés d'usine, sont des sectionneurs du type: apte à l'interruption en charge conforme à EN 60947-3 (équivalent à CEI 60947-3) 6. Les unités sont conçues pour être raccordées sur des réseaux type TN (CEI 60364). En cas de réseaux IT, la mise à la terre ne peut se faire sur la terre du réseau. Prévoir une terre locale, consulter les organismes locaux compétents pour réaliser l'installation électrique. Attention Si les aspects particuliers d'une installation nécessitent des caractéristiques différentes de celles listées ci-dessus (ou non évoquées), contacter votre correspondant Carrier. * Le niveau de protection requis au regard de cette classification est IP43BW (selon le document de référence CEI 60529). Toutes les unités 30RH étant IP44CW remplissent cette condition de protection. Limites de fonctionnement Débit d'eau de l'échangeur 30RH 040 050 060 070 080 090 100 120 140 160 200 240 Débit minimum l/s 1, 0 1, 1 1, 4 1, 5 1, 7 2, 3 2, 6 3, 1 3, 5 4, 2 5, 3 6, 3 Mode chaud Température d'entrée d'eau au démarrage 30RH 040 - 240 Minimum , °C 10 Mode froid Température d'entrée d'eau au démarrage 30RH 040 - 240 * ** Débit maximum* l/s Pompe simple 3, 5 4, 0 4, 4 4, 6 5, 5 5, 6 5, 8 8, 5 8, 8 9, 1 23, 4 23, 4 Débit maximum** l/s Pompe double 4, 4 5, 2 6, 0 6, 4 6, 8 6, 9 7, 4 10, 5 11, 4 11, 9 23, 4 23, 4 3, 7 4, 6 5, 8 6, 4 7, 3 7, 6 8, 8 10, 8 12, 7 14, 4 24, 2 24, 2 Température d'entrée d'eau à l'arrêt Minimum °C 3 Maximum °C 60 Température de sortie d'eau en fonctionnement Minimum , °C Maximum °C 20 50 Température d'entrée d'air Minimum °C -10 Maximum °C 40 Maximum °C 45 Température d'entrée d'eau à l'arrêt Maximum °C 60 Température de sortie d'eau en fonctionnement Minimum , °C Maximum °C 5 15 Température d'entrée d'air Minimum °C -10 Maximum °C 46 Minimum , °C 7, 8 Maximum °C 30 Légende: Débit maximum correspondant à une pression disponible de 50 kPa (unité avec module hydraulique). Débit maximum correspondant à une perte de charge de 100 kPa dans l'échangeur à plaques (unité sans module hydraulique). Pour une application nécessitant un fonctionnement à moins de 7, 8°C, contacter Carrier. Pour une application nécessitant un fonctionnement à moins de 5°C, l'emploi d'antigel est nécessaire. Plage de fonctionnement en mode froid. Plage de fonctionnement en mode chaud. °C °C 46 45 44. 5 44 Température d'entrée d'air 40 35 30 Température d'entrée d'air 25 20 15 10 5 0 -5 -10 20 25 30 35 40 45 50 °C 0 -10 0 1 2 3 4 5 6 7 8 9 10 °C Température de sortie d'eau Notes: 1 Echangeur à eau T = 5 K 2 L'échangeur à eau et le module hydraulique sont protégés contre le gel jusqu'à -20°C. Température de sortie d'eau Plage de fonctionnement avec solution antigel obligatoire et configuration spéciale de la régulation Pro-Dialog Pression statique disponible pour l'installation Pompe simple 325 300 275 250 Pression statique disponible, kPa 225 200 175 150 125 100 75 4 50 25 0 Légende 1 30 RH 040 2 30 RH 050 3 30 RH 060 4 30 RH 070 5 30 RH 080 - 090 2 1 2 4 3 5 6 6 7 8 8 9 10 12 Débit d'eau, l/s 14 16 18 20 22 10 24 6 7 8 9 10 30 RH 100 30 RH 120 30 RH 140 30 RH 160 30 RH 200 - 240 Pompe double 325 300 275 250 225 200 175 150 125 100 7 75 50 1 25 0 Légende 1 30 RH 040 2 30 RH 050 3 30 RH 060 4 30 RH 070 5 30 RH 080 6 30 RH 090 2 4 6 2 3 4 5 8 10 8 9 10 12 Débit d'eau, l/s 7 8 9 10 11 30 RH 100 30 RH 120 30 RH 140 30 RH 160 30 RH 200-240 14 16 18 20 22 11 24 6 Pression statique disponible, kPa Volume de la boucle d'eau Volume minimum de la boucle d'eau Volume = CAP (kW) x N* = litres, où CAP est la puissance nominale de refroidissement à la condition nominale d'utilisation. Application conditionnement d'air 30RH 040 30RH 050 à 240 N* 3. 5 2. 5 Eau pure EG 10% EG 20% EG 35% Voir note 30 RH 040-080 (en litres) 600 450 400 300 30 RH 090-160 (en litres) 1500 1200 1000 800 30 RH200-240 (en litres) 2000 1600 1400 1000 Volume maximum de la boucle d'eau Les unités avec module hydraulique intègrent un vase d'expansion qui limite le volume de la boucle d'eau. Le tableau ci-dessous donne le volume maximum de la boucle pour de l'eau pure ou de l'éthylène glycol avec différentes concentrations. Refroidissement process industriel 30 RH 040 à 240 EG: Ethylène Glycol Note Pour les applications de process industriels où il est nécessaire d'obtenir une stabilité importante de la température d'eau, les valeurs citées ci-dessus doivent être augmentées. Dimensions/dégagements 30RH 040-080 1081 2071 1329 1000 1000 Légende: Toutes les dimensions sont en mm 1 Alimentation électrique Espaces nécessaires pour l'arrivée d'air Espaces conseillés pour la maintenance 1 2 Entrée d'eau Sortie d'eau Entrée câble puissance 1000 2 Sortie d'air, ne pas obstruer Note: Plans non contractuels. Consulter les plans dimensionnels certifiés disponibles sur demande lors de la conception d'une installation. 1000 Dimensions/dégagements 30RH 090-160 2278 2071 1329 1000 1 1 2 2 1 1000 1 1000 1000 30RH 200-240 2279 3351 1674 1000 1 2 1 Légende: Toutes les dimensions sont en mm Alimentation électrique 2 2 Espaces nécessaires pour l'arrivée d'air Espaces conseillés pour la maintenance Entrée d'eau 1 1000 Sortie d'eau 1 2 Entrée câble puissance 1000 1000 Sortie d'air, ne pas obstruer Note: Plans non contractuels. Consulter les plans dimensionnels certifiés disponibles sur demande lors de la conception d'une installation. 30RH -5 COMP UNIT COND PRES PRES CAP (1) (2) COMP UNIT COND PRES PRES CAP (1) (2) COMP UNIT COND PRES PRES CAP (1) (2) COMP UNIT COND PRES PRES (1) (2) Température d'entrée d'air 0 7 10 LWT -10 CAP COMP UNIT COND PRES PRES CAP (1) (2) °C kW kW kW l/s kPa kPa kPa kW kW kW l/s kPa kPa kPa kW kW kW l/s kPa kPa kPa kW kW kW l/s kPa kPa kPa kW kW kW l/s kPa kPa kPa 040 050 060 070 080 090 100 120 140 160 200 240 25, 6 31, 2 38, 3 43, 7 52 57 64 77 87 105 136 155 25 30, 5 37, 4 42, 7 51 55 62 75 85 102 134 152 10, 8 13, 8 16, 3 18, 2 22, 1 24, 6 27, 1 32, 6 36, 4 44, 1 58 72 12 15 17, 5 20, 7 24, 6 27 29, 5 35 41, 4 49, 1 66 82 1, 19 1, 46 1, 78 2, 04 2, 44 2, 65 2, 98 3, 57 4, 08 4, 88 6, 4 7, 24 12 11 10 11 12 15 14 14 14 15 9 12 160 160 159 155 193 187 180 212 207 194 276 270 206 206 207 205 202 198 196 193 192 188 276 270 30 36, 6 44, 9 51 61 67 75 90 103 123 160 182 11, 1 14, 2 16, 9 18, 8 22, 8 25, 4 28 33, 7 37, 7 45, 6 60 74 12, 3 15, 4 18, 1 21, 3 25, 3 27, 8 30, 4 36, 1 42, 7 51 67 84 1, 43 1, 75 2, 15 2, 45 2, 93 3, 18 3, 58 4, 29 4, 9 5, 87 7, 63 8, 71 17 16 15 16 18 21 20 20 19 21 13 16 155 154 151 146 178 169 160 199 190 170 267 258 201 202 201 199 193 188 185 186 185 178 267 258 39, 9 49, 3 60 68 81 89 100 119 136 162 196 235 12, 3 15, 5 18, 3 20, 7 24, 7 27, 8 30, 7 36, 6 41, 3 49, 4 58 70 13, 5 16, 7 19, 5 23, 2 27, 2 30, 2 33, 1 39 46, 3 54 66 80 1, 9 2, 35 2, 85 3, 25 3, 88 4, 26 4, 76 5, 7 6, 5 7, 75 9, 38 11, 2 30 28 26 28 31 37 35 34 32 35 19 26 140 136 129 119 142 125 109 162 146 107 252 233 189 188 186 181 171 161 154 167 164 150 252 233 9, 74 12, 5 14, 8 16, 4 19, 9 22, 2 24, 5 29, 6 32, 8 39, 9 53 66 10, 9 13, 7 16 18, 9 22, 4 24, 6 26, 9 32 37, 8 44, 9 60 76 1, 22 1, 49 1, 83 2, 09 2, 5 2, 71 3, 05 3, 66 4, 18 5 6, 49 7, 42 12 11 11 12 13 16 15 15 14 16 10 12 159 159 158 154 191 185 178 211 205 191 276 269 205 206 206 204 201 197 195 192 192 187 276 269 30, 6 37, 4 45, 8 52 63 68 76 92 105 125 162 186 10, 1 12, 9 15, 3 17 20, 7 23 25, 4 30, 7 34 41, 4 54 68 11, 3 14, 1 16, 5 19, 5 23, 2 25, 4 27, 8 33, 1 39 46, 4 62 78 1, 46 1, 79 2, 19 2, 5 2, 99 3, 25 3, 65 4, 38 5 5, 99 7, 72 8, 88 17 16 16 17 19 22 21 21 20 22 13 17 154 153 150 144 176 167 157 197 188 166 266 256 200 201 200 198 192 187 183 185 184 176 266 256 40, 8 52 61 69 83 92 102 122 138 166 200 241 11, 2 13, 9 16, 5 18, 7 22, 1 25, 1 27, 6 32, 9 37, 3 44, 2 52 63 12, 4 15, 1 17, 7 21, 2 24, 6 27, 5 30 35, 3 42, 3 49, 2 60 74 1, 95 2, 47 2, 92 3, 31 3, 96 4, 42 4, 87 5, 85 6, 61 7, 92 9, 54 11, 5 31 31 28 29 33 40 36 35 33 37 20 28 138 132 126 116 138 117 103 158 142 100 250 230 187 185 185 180 169 156 151 165 162 146 250 230 44, 3 55 66 75 89 100 110 132 150 178 212 259 43, 4 53 64 74 87 96 108 129 148 175 208 253 11, 3 14, 1 16, 7 18, 9 22, 4 25, 5 28 33, 4 37, 9 44, 8 53 64 12, 5 15, 7 18, 5 20, 9 25 28, 2 31 37, 1 41, 9 49, 9 59 71 12, 5 15, 3 17, 9 21, 4 24, 9 27, 9 30, 4 35, 8 42, 9 49, 8 60 74 13, 7 16, 9 19, 7 23, 4 27, 5 30, 6 33, 4 39, 5 46, 9 55 66 81 2, 12 2, 64 3, 14 3, 58 4, 26 4, 75 5, 26 6, 29 7, 16 8, 53 10, 1 12, 4 2, 07 2, 52 3, 07 3, 52 4, 18 4, 59 5, 14 6, 15 7, 05 8, 36 9, 96 12, 1 37 36 32 34 38 45 42 40 38 42 22 32 35 33 31 33 37 43 40 38 37 40 21 30 131 125 118 104 124 100 83 143 122 75 245 220 133 129 121 107 128 108 89 148 126 82 246 224 Puissance calorifique par basse température extérieure Les puissances calorifiques annoncées sont des puissances instantanées. Elles ne tiennent pas compte de la diminution de la puissance calorifique résultant de la formation de givre sur la batterie et de l'effet des cycles de dégivrage. La puissance calorifique intégrée prend en compte ces conséquences qui sont facteur de la température et de l'humidité relative (HR) de l'air extérieur. Facteur de correction à appliquer pour obtenir la puissance calorifique intégrée Température de sortie d'eau °C Température extérieure °C (HR 87%) -10 30 35 40 45 50 0, 88 0, 87 0, 88 0, 89 0, 91 -5 0, 85 0, 85 0, 85 0, 86 0, 89 0 0, 87 0, 87 0, 87 0, 88 0, 91 7 1 1 1 1 1 10 1 1 1 1 1 30 22, 7 27, 7 34 38, 8 46, 5 50 57 68 78 93 115 138 8, 79 11, 3 13, 4 14, 7 18 20, 1 22, 2 26, 8 29, 5 36 46, 5 60 9, 99 12, 5 14, 6 17, 2 20, 5 22, 5 24, 6 29, 2 34, 5 41 54 70 1, 09 1, 32 1, 62 1, 85 2, 22 2, 41 2, 71 3, 25 3, 71 4, 44 5, 48 6, 59 10 9 9 9 10 13 12 12 11 13 7 10 162 162 161 159 199 193 188 217 213 203 282 275 207 208 208 207 205 202 200 196 195 192 282 275 25, 9 31, 6 38, 8 44, 3 53 58 65 78 89 106 138 157 8, 85 11, 4 13, 5 14, 9 18, 1 20, 2 22, 4 27 29, 7 36, 2 47, 6 60 10, 1 12, 6 14, 7 17, 4 20, 6 22, 6 24, 8 29, 4 34, 7 41, 2 55 70 1, 24 1, 51 1, 85 2, 12 2, 53 2, 75 3, 09 3, 71 4, 23 5, 07 6, 57 7, 52 13 12 11 12 13 16 16 15 15 16 10 13 159 159 157 154 191 184 177 210 204 190 275 268 205 206 206 204 201 196 194 192 191 186 275 268 31 37, 8 46, 3 53 63 69 77 93 106 127 163 188 9, 22 11, 8 14 15, 5 18, 9 21, 1 23, 3 28, 1 31 37, 7 49, 3 63 10, 4 13 15, 2 18 21, 4 23, 5 25, 7 30, 5 36 42, 7 57 73 1, 48 1, 81 2, 21 2, 53 3, 03 3, 29 3, 69 4, 43 5, 06 6, 06 7, 8 8, 98 18 17 16 17 19 23 22 21 20 22 13 17 153 152 149 143 175 166 156 196 187 165 265 255 200 201 200 197 192 186 182 185 183 175 265 255 42, 1 54 63 70 86 97 105 126 141 171 204 248 10, 1 12, 5 14, 8 16, 9 19, 9 22, 7 24, 9 29, 6 33, 7 39, 7 47, 2 57 11, 3 13, 7 16 19, 4 22, 4 25, 1 27, 3 32 38, 7 44, 7 55 68 2, 01 2, 6 3, 01 3, 36 4, 09 4, 61 5, 02 6, 02 6, 72 8, 17 9, 74 11, 9 33 35 29 30 35 43 38 37 34 39 20 29 136 126 123 114 132 107 96 152 138 90 248 226 185 181 182 178 165 149 146 162 160 142 248 226 45, 6 58 68 76 92 104 113 135 152 184 216 267 10, 3 12, 7 15 17, 1 20, 1 23 25, 3 30 34, 3 40, 3 47, 6 58 11, 5 13, 9 16, 2 19, 6 22, 6 25, 4 27, 7 32, 4 39, 3 45, 3 55 68 2, 18 2, 77 3, 23 3, 64 4, 39 4, 95 5, 41 6, 46 7, 27 8, 78 10, 3 12, 7 39 39 34 36 40 49 44 42 39 44 23 33 129 119 114 101 117 89 75 137 118 64 243 216 179 175 176 170 155 138 133 155 150 130 243 216 181 179 179 172 160 145 138 158 152 135 245 220 183 183 181 174 162 150 142 160 154 138 246 224 040 050 060 070 080 090 100 120 140 160 200 240 35 22, 4 27, 3 33, 5 38, 2 45, 8 49, 7 56 67 76 92 113 136 9, 67 12, 4 14, 7 16, 3 19, 8 22, 1 24, 4 29, 4 32, 6 39, 6 51 65 10, 9 13, 6 15, 9 18, 8 22, 3 24, 5 26, 8 31, 8 37, 6 44, 6 59 75 1, 07 1, 3 1, 6 1, 83 2, 19 2, 37 2, 67 3, 2 3, 65 4, 37 5, 4 6, 49 9 9 8 9 10 12 12 11 11 12 7 10 162 162 162 159 200 194 189 218 214 204 283 276 208 208 209 208 205 202 201 196 196 193 283 276 040 050 060 070 080 090 100 120 140 160 200 240 40 21, 8 26, 6 32, 6 37, 2 44, 5 48, 3 54 65 74 89 111 132 10, 7 13, 7 16, 2 18, 1 21, 9 24, 4 26, 9 32, 5 36, 2 43, 9 57 72 11, 9 14, 9 17, 4 20, 6 24, 4 26, 8 29, 3 34, 9 41, 2 48, 9 65 82 1, 04 1, 27 1, 56 1, 78 2, 13 2, 31 2, 6 3, 11 3, 55 4, 25 5, 31 6, 31 9 8 8 8 9 12 11 11 11 12 7 9 162 163 162 160 201 196 191 219 215 206 283 277 208 209 209 208 206 203 202 197 196 194 283 277 Puissances calorifiques pompe simple et pompe double Légende: LWT CAP kW COMP kW UNIT kW COND l/s COND kPa PRES kPa (1) PRES kPa (2) Température de sortie d'eau Puissance calorifique instantanée Puissance absorbée par les compresseurs Puissance absorbée de l'unité (compresseurs, ventilateurs, contrôle) Débit d'eau condenseur Perte de charge condenseur Pression disponible à la sortie de l'unité avec module hydraulique pompe simple Pression disponible à la sortie de l'unité avec module hydraulique pompe double Facteurs de correction à pleine charge pour test en laboratoire EUROVENT: Puissance calorifique nette: 1. 000 Coefficient d'efficacité énergétique: 1. 000 Perte de charge à l'échangeur: 1. 000 Données d'application: Unités standards, Réfrigérant R407C Différence entrée/sortie d'eau au condenseur: 5K Fluide au condenseur: eau Coefficient d'encrassement: 0. 44x10-4 (m2 K) / W Performances établies selon EN 255 Note: Le programme de sélection électronique Carrier permet de calculer la puissance calorifique intégrée en fonction des conditions réelles d'humidité du lieu d'installation. Contacter Carrier pour une sélection personnalisée de la pompe à chaleur. 30RH 0 COMP UNIT COND PRES PRES CAP (1) (2) COMP UNIT COND PRES PRES CAP (1) (2) COMP UNIT COND PRES PRES CAP (1) (2) COMP UNIT COND PRES PRES (1) (2) Température d'entrée d'air 7 10 LWT -10 -5 CAP COMP UNIT COND PRES PRES CAP (1) (2) °C kW kW kW l/s kPa kPa kPa kW kW kW l/s kPa kPa kPa kW kW kW l/s kPa kPa kPa kW kW kW l/s kPa kPa kPa kW kW kW l/s kPa kPa kPa 040 050 060 070 080 090 100 120 140 160 200 240 28 34, 2 41, 9 47, 9 57 62 70 84 96 115 155 170 13, 7 17, 4 20, 6 23, 3 28, 1 31, 1 34, 3 41, 2 46, 5 56 74 89 14, 9 18, 6 21, 8 25, 8 30, 6 33, 5 36, 7 43, 6 52 61 81 100 1, 34 1, 63 2 2, 29 2, 74 2, 97 3, 34 4, 01 4, 58 5, 48 7, 42 8, 13 15 14 13 14 16 19 18 17 17 19 12 15 157 157 154 150 184 177 169 204 197 180 269 263 203 204 203 201 197 192 190 189 188 182 269 263 38, 8 45, 8 57 65 80 85 96 115 131 160 193 225 15, 1 18, 9 22, 5 25, 3 30, 7 34 37, 7 45, 1 51 61 73 86 16, 3 20, 1 23, 7 27, 8 33, 2 36, 4 40, 1 47, 5 56 66 80 97 1, 86 2, 19 2, 75 3, 13 3, 82 4, 05 4, 6 5, 49 6, 25 7, 65 9, 23 10, 8 28 25 25 26 30 34 33 31 30 34 18 24 142 141 133 123 144 135 117 168 153 111 253 238 190 192 189 184 173 167 159 171 167 151 253 238 42, 4 49, 4 62 71 86 92 104 124 142 173 205 243 15, 3 19, 1 22, 8 25, 6 31 34, 4 38, 1 45, 5 51 62 73 87 16, 5 20, 3 24 28, 1 33, 5 36, 8 40, 5 47, 9 56 67 80 97 2, 02 2, 36 2, 97 3, 4 4, 13 4, 38 4, 99 5, 93 6, 8 8, 25 9, 81 11, 6 33 29 29 31 36 39 38 36 35 40 21 28 135 136 125 112 130 119 98 155 135 87 248 229 45 - - - - - - - 24, 1 29, 4 36, 1 41, 2 49, 3 54 60 72 82 99 132 146 12 15, 3 18, 1 20, 3 24, 5 27, 3 30, 1 36, 1 40, 5 49, 1 65 79 13, 2 16, 5 19, 3 22, 8 27 29, 7 32, 5 38, 5 45, 5 54 72 89 1, 15 1, 41 1, 72 1, 97 2, 36 2, 56 2, 87 3, 45 3, 93 4, 71 6, 3 6, 99 11 10 10 10 12 14 14 13 13 14 9 11 161 161 160 157 195 189 184 214 209 198 277 272 206 207 207 206 203 200 198 194 194 190 277 272 29, 2 35, 6 43, 6 49, 8 60 65 73 87 100 119 158 177 12, 3 15, 7 18, 6 20, 9 25, 3 28, 1 30, 9 37, 2 41, 8 51 66 81 13, 5 16, 9 19, 8 23, 4 27, 8 30, 5 33, 3 39, 6 46, 8 56 74 91 1, 39 1, 7 2, 08 2, 38 2, 85 3, 09 3, 48 4, 17 4, 76 5, 7 7, 53 8, 46 16 15 14 15 17 20 19 19 18 20 13 16 156 155 152 148 181 173 164 201 193 174 268 260 202 203 202 200 195 190 187 187 186 180 268 260 39, 2 47, 3 58 67 80 87 98 117 133 160 194 229 13, 7 17, 1 20, 3 22, 9 27, 5 30, 8 34 40, 7 45, 8 55 65 78 14, 9 18, 3 21, 5 25, 4 30 33, 2 36, 4 43, 1 51 60 73 88 1, 87 2, 26 2, 79 3, 19 3, 83 4, 13 4, 66 5, 58 6, 38 7, 66 9, 28 11 29 26 25 27 31 35 33 32 31 35 19 25 141 139 131 121 144 131 114 166 149 111 253 236 190 190 188 183 172 164 157 169 165 151 253 236 42, 7 51 63 73 86 94 106 126 145 173 206 248 13, 8 17, 3 20, 6 23, 2 27, 8 31, 2 34, 4 41, 1 46, 3 56 65 79 15 18, 5 21, 8 25, 7 30, 3 33, 6 36, 8 43, 5 51 61 73 89 2, 04 2, 43 3, 01 3, 46 4, 13 4, 47 5, 05 6, 03 6, 93 8, 27 9, 86 11, 8 34 30 29 32 36 40 39 37 36 40 21 29 135 133 123 109 130 114 94 152 131 86 247 226 184 186 182 175 164 154 145 162 157 140 247 226 185 188 183 177 164 157 147 164 159 140 248 229 040 050 060 070 080 090 100 120 140 160 200 240 50 - - - - - - - - Puissance calorifique par basse température extérieure Les puissances calorifiques annoncées sont des puissances instantanées. [. . . ] L'unité peut fonctionner en toute sécurité avec un faible volume d'eau dans l'installation, ce qui permet très souvent de supprimer le ballon tampon (voir volume d'eau minimum dans la documentation). I Régulation de la pression de condensation par algorithme auto-adaptatif (vitesse du ventilateur). I Commande de la pompe à eau (pompe double en option avec permutation automatique). I Gestion des cycles de dégivrage avec auto-adaptation des paramètres. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CARRIER 23422-PSD-09-2003

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CARRIER 23422-PSD-09-2003 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag