User manual CARRIER 42EACC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CARRIER 42EACC. We hope that this CARRIER 42EACC user guide will be useful to you.

Lastmanuals help download the user guide CARRIER 42EACC.


Mode d'emploi CARRIER 42EACC
Download
Manual abstract: user guide CARRIER 42EACC

Detailed instructions for use are in the User's Guide.

[. . . ] Aquasnap est équipé en standard d'un module hydraulique complet limitant l'installation à de simples opérations de câblage électrique, et de raccordement des tuyauteries de départ et de retour d'eau. Caractéristiques Ventilateur axial silencieux à pression disponible: Contrairement à un ventilateur centrifuge ce ventilateur ne nécessite pas de réglage à l'installation car son débit est peu dépendant des pertes de charge du réseau aéraulique. Comme le ventilateur est directement monté sur le moteur il n'y a pas de courroie à ajuster et à remplacer. A charge partielle ou par température extérieure peu élevée, le ventilateur est automatiquement basculé en petite vitesse. [. . . ] Le système mesure en permanence l'évolution des paramètres de fonctionnement et réagit pour éviter les cyclages excessifs et maintenir le compresseur dans sa plage idéale de fonctionnement (températures pressions hors limites. . . ). En anticipant les actions correctrices, la régulation auto-adaptatrice évite le plus souvent un arrêt sur défaut de la pompe à chaleur. Interface opérateur PRO-DIALOG Plus 2 Options et accessoires Option Pré-traitement anti-corrosion de l'échangeur à air, recommandé pour les ambiances marines Démarreur électronique du compresseur pour réduction du courant de démarrage (30RYH 040 - 080) Unité sans module hydraulique Module hydraulique avec pompe double (30RYH 040-080) Carte de commande de résistances électriques d'appoint (3 étages + 1 étage de secours) Support unité avec bac de récupération des condensats Filtre à air a l'aspiration monté sur glissière Installation extérieure (30RYH 040-080) Carte de communication avec protocole ouvert JBus X X X X X X X X X X Accessoire 21 6 5 20 4 2 7 8 3 1 24 9 14 16 23 22 Module hydraulique (040 à 080) 2 12 14 17 15 1 4 13 3 10 5 18 6 11 Légende Composants du module hydraulique et de l'unité 1 Filtre à tamis (Victaulic) 2 Vase d'expansion 3 Soupape de sécurité 4 Pompe à pression disponible 5 Vanne de purge et de prise de pression (voir Manuel d'installation) 6 Manomètre pour lecture de la perte de charge échangeur à plaques (à isoler par vanne n° 5 lorsque non utilisé). 7 Purge d'air du système 8 Détecteur de débit 9 Vanne de réglage du débit d'eau 10 Echangeur à plaques 11 Réchauffeur pour mise hors gel de l'évaporateur Composants de l'installation 12 Purge d'air 13 Doigt de gant température 14 Raccord flexible 15 Vannes d'arrêt 16 Bouchon de vidange eau du système (sur tube de connexion livré dans la machine) 17 Manomètre 18 Vanne by pass pour protection anti-gel (si fermeture des vannes n° 15 en hiver) 19 Vanne de remplissage 20 Sortie échangeur à plaques 21 Entrée échangeur à plaques 22 Entrée d'eau 23 Sortie d'eau 24 Manchettes de raccordement client pour soudure ou filetage (fournies) ------ Module hydraulique (unité avec module hydraulique) Nota: Les unités sans module hydraulique (option) sont équipées du détecteur de débit et d'un réchauffeur de tuyauterie interne 7 17 13 14 15 9 8 5 19 16 Schéma de principe du circuit hydraulique 3 Caractéristiques physiques 30RYH Puissance calorifique nominale** Puissance frigorifique nominale* Poids en fonctionnement avec module hydraulique pompe simple Poids en fonctionnement avec module hydraulique pompe double Poids en fonctionnement sans module hydraulique Fluide frigorigène R407C Compresseurs Quantité Nombre d'étages de puissance Puissance minimum Régulation Echangeur à air Ventilateur Quantité Pression statique disponible* Débit d'air total (grande vitesse) Vitesse de rotation (grande/petite vitesse) Echangeur à eau Volume d'eau Pression max. de fonctionnement côté eau (option sans module hydraulique) Pression max. de fonctionnement côté eau (avec module hydraulique) Module hydraulique Pompe (centrifuge) Quantité Volume vase d'expansion Pression vase d'expansion Connexion d'eau (avec et sans module hydraulique) Diamètre Diamètre extérieur du tube kW kW kg kg kg kg 017 18, 3 17, 8 410 385 6, 4 021 22, 1 22, 4 440 415 6, 6 026 25, 6 24, 1 460 435 7, 4 033 34, 5 31, 3 475 450 8, 6 1 1 100 040 37 37, 8 550 630 526 10, 3 1 1 100 050 48, 3 44, 7 612 692 588 11, 4 2 2 46 060 55 56 627 707 603 12, 5 2 2 42 070 62 65 688 768 664 13, 3 2 2 50 080 78 76 736 813 710 17, 3 2 2 50 % Hermétique Scroll 48, 3 tr/s 1 1 1 1 1 1 100 100 100 PRO-DIALOG Plus Tubes en cuivre rainuré et ailettes en aluminium Axial à pression disponible 1 1 1 100 100 100 1940 1940 1940 24/12 24/12 24/12 1 100 2500 24/12 1 150 3890 24/12 1 150 3890 24/12 4, 6 1000 300 1 150 4720 24/12 5, 9 1000 300 1 150 5830 24/12 6, 5 1000 300 1 150 5830 24/12 7, 6 1000 300 Pa l/s tr/s l kPa kPa A détente directe, de type à plaques brasées 1, 6 2, 0 2, 3 3, 0 3, 6 1000 250 1000 250 1000 250 1000 250 1000 300 l kPa Pompe simple centrifuge multicellulaire 48, 3 tr/s 1 1 1 1 8 8 8 8 50 50 50 50 Gaz filetée conique mâle Pompe simple centifuge, monocellulaire composite 48, 3 tr/s 1 1 1 1 1 12 12 12 12 12 100 100 100 100 100 Victaulic (manchettes pour soudure ou filetage fournies) 2 2 2 2 2 2 2 2 2 2 60, 3 60, 3 60, 3 60, 3 60, 3 pouce pouce mm 1-1/4 1-1/4 42, 4 1-1/4 1-1/4 42, 4 1-1/4 1-1/4 42, 4 1-1/4 1-1/4 42, 4 * Conditions nominales : entrée et sortie d'eau évaporateur = 12°C / 7°C. Température d'air extérieur = 35°C ** Conditions nominales : entrée et sortie d'eau = 40/45°C. Température d'air extérieur = 7°C Niveaux sonores 30RYH Puissances Acoustiques dB(A) 10-12W Puissances Acoustiques dB(A) 10-12W ventilateurs en basse vitesse 017 82 69 021 83 77 026 83 77 033 85 79 040 91 81 050 91 80 060 89 82 070 91 83 080 91 84 Note: Etablis selon EUROVENT 8/1 (issus de ISO standard 3744 ou ISO 9614-1) 4 Caractéristiques électriques 30RYH (sans module hydraulique) Circuit puissance Tension nominale Plage de tension Alimentation du circuit de commande Puissance absorbée maxi de l'unité * Intensité nominale de l'unité** Intensité maximum de l'unité à 360V*** Intensité maximum de l'unité à 400V**** Intensité maximum au démarrage Unité standard Unité avec option démarreur électronique Intensité de tenue aux court-circuits triphasés kW A A A A kA V-ph-Hz V 017 400-3-50 360-440 Le circuit de commande est alimenté par un transformateur présent dans l'unité 9, 8 13, 1 17 15, 5 87, 8 6 12, 1 16, 2 21, 3 19, 3 131, 8 6 13, 8 18, 6 24, 5 22, 2 131, 8 6 18 23, 3 31, 2 28, 3 147, 4 6 21 28, 8 37, 8 34, 5 159, 3 97, 3 6 25, 3 35, 6 46, 5 42, 3 151, 8 96, 7 6 32, 3 45, 7 59, 5 54, 3 173, 5 111, 9 6 38, 2 52, 1 67, 8 62, 1 181, 2 118, 2 6 42, 9 59, 4 77, 5 70, 7 195, 5 127, 9 6 021 026 033 040 050 060 070 080 Légende : * Puissance absorbée, compresseur(s) + ventilateur(s) aux limites de fonctionnement. (Entrée/Sortie d'eau = 15°C /10°C, température de condensation maximum de 67, 8°C et à la tension nominale de 400 V). Indications portées sur la plaque signalétique de l'unité. ** Intensité nominale de fonctionnement de l'unité aux conditions suivantes: Entrée/Sortie d'eau évaporateur 12°C/ 7°C, température d'air extérieur 35°C. Les intensités sont données à la tension nominale de 400V. *** Intensité maximum de fonctionnement de l'unité à la puissance absorbée maximum de l'unité et sous 360 V **** Intensité maximum de fonctionnement de l'unité à la puissance absorbée maximum de l'unité et sous 400 V (Indications portées sur la plaque signalétique de l'unité) Intensité maximum de démarrage à la tension nominale de 400 V avec compresseur en démarrage direct (courant de service maximum du ou des plus petits compresseurs + intensités du ou des ventilateurs + intensité rotor bloqué du plus gros compresseur). Contacter Carrier pour une sélection personnalisée de la pompe à chaleur. 30RYH 35 COMP UNIT COOL COOL PRES PRES CAP COMP UNIT COOL COOL PRES PRES CAP COMP UNIT COOL COOL PRES PRES CAP COMP UNIT COOL COOL PRES PRES Température d'entrée d'air au condenseur 40 (1) kW kW kW l/s kPa kPa kPa kW kW kW l/s kPa kPa kPa kW kW kW l/s kPa kPa kPa (2) (1) (2) (1) (2) LWT 25 (1) kW kW l/s kPa kPa kPa (2) 30 45 CAP COMP UNIT COOL COOL PRES PRES CAP (1) (2) °C kW 235 235 16, 6 5, 75 6, 75 0, 79 27 210 210 20, 9 7, 66 8, 66 1 207 207 22, 5 8, 55 9, 55 1, 08 23 160 160 29, 2 11, 7 13, 2 1, 39 25 144 192 35, 3 13, 5 15, 4 1, 68 21 144 194 41, 9 16, 9 18, 8 2 135 191 53 126 186 61 152 178 72 230 230 17, 2 5, 8 204 204 21, 7 7, 73 8, 73 1, 04 30 200 200 23, 3 8, 63 9, 63 1, 11 25 151 151 30, 2 11, 8 13, 3 1, 44 26 142 190 36, 5 13, 6 15, 5 1, 75 23 141 192 43, 3 17, 1 19 132 189 55 122 183 63 147 175 74 225 225 17, 8 5, 85 6, 85 0, 85 31 197 197 22, 4 7, 8 193 193 24, 1 8, 71 9, 71 1, 15 27 141 141 31, 3 11, 9 13, 4 1, 49 28 140 188 37, 8 13, 8 15, 7 1, 81 24 139 190 44, 7 17, 3 19, 2 2, 14 21 129 186 56 118 181 65 142 171 76 27, 9 33, 4 3, 64 25 23, 8 29, 3 3, 1 23 20, 2 23, 6 2, 7 21 8, 8 1, 07 32 27, 6 33, 1 3, 53 24 156 180 69 23, 6 29, 1 3 22 128 187 59 19, 9 23, 3 2, 61 20 138 192 51 21, 9 25, 3 2, 46 18 25, 8 31, 3 2, 83 19 30, 3 35, 8 3, 32 21 28 2, 07 20 145 195 40, 7 18, 9 20, 8 1, 94 18 145 193 34, 4 15 16, 9 1, 64 20 165 165 28, 6 12, 9 14, 4 1, 36 24 210 210 22, 1 9, 47 10, 5 1, 05 22 214 214 20, 5 8, 48 9, 48 0, 98 27 6, 8 0, 82 29 237 237 16, 2 6, 4 7, 4 0, 78 26 27, 3 32, 8 3, 42 22 161 183 67 30 35, 5 3, 21 20 169 188 63 23, 3 28, 8 2, 9 20 132 190 57 25, 5 31 2, 73 18 137 193 54 19, 7 23, 1 2, 52 19 140 194 49, 7 21, 6 25 2, 37 17 19 147 197 39, 3 18, 7 20, 6 1, 88 16 147 195 33, 2 14, 8 16, 7 1, 59 19 174 174 27, 5 12, 8 14, 3 1, 32 22 187 187 25, 9 14 15, 5 1, 24 20 150 197 31, 2 16, 2 18, 1 1, 49 17 151 199 36, 6 20, 5 22, 4 1, 75 14 145 197 46, 5 23, 7 27, 1 2, 22 15 27, 9 33, 4 2, 56 16 32, 8 38, 3 2, 99 17 216 216 21, 3 9, 39 10, 4 1, 02 21 226 226 20 10, 3 11, 3 0, 96 18 28 220 220 19, 7 8, 41 9, 41 0, 94 25 229 229 18, 5 9, 21 10, 2 0, 88 22 242 242 15, 7 6, 35 7, 35 0, 75 25 248 248 14, 7 6, 99 7, 99 0, 7 22 255 255 238 238 235 235 200 200 153 200 154 202 149 200 143 197 176 192 251 251 233 233 229 229 193 193 152 199 149 198 38 134 191 55 165 185 65 20, 7 22, 6 1, 82 15 142 195 48, 2 23, 9 27, 3 2, 3 33, 2 38, 7 3, 1 16 28, 2 33, 7 2, 65 17 18 240 240 15, 8 7, 09 8, 09 0, 76 25 218 218 19, 9 9, 36 10, 4 0, 95 25 214 214 21, 5 10, 4 11, 4 1, 03 21 14, 5 1, 41 25 1, 7 22 2, 01 19 22, 1 25, 5 2, 54 19 125 185 61 152 177 72 26, 1 31, 6 2, 92 21 30, 7 36, 2 3, 42 22 171 171 27, 8 14, 2 15, 7 1, 33 23 147 194 33, 4 16, 6 18, 5 1, 6 19 147 196 39, 4 20, 9 22, 8 1, 88 17 140 194 49, 8 24, 2 27, 6 2, 38 17 131 189 57 161 183 67 28, 5 34 2, 74 18 33, 6 39, 1 3, 2 19 152 200 147 198 140 195 173 190 247 247 228 228 224 224 185 185 150 197 151 199 145 197 137 193 169 188 kW kW l/s kPa kPa kPa kW 017 5 18, 4 4, 67 5, 67 0, 88 33 228 228 17, 5 5, 19 6, 19 0, 84 30 021 23, 3 6, 32 7, 32 1, 11 35 200 200 22, 1 6, 96 7, 96 1, 06 32 026 24, 9 7, 06 8, 06 1, 19 29 197 197 23, 7 7, 77 8, 77 1, 13 26 033 32, 3 9, 66 11, 2 1, 54 30 146 146 30, 8 10, 6 12, 1 1, 47 27 040 17, 9 21, 3 2, 68 21 21, 2 26, 7 3, 06 23 24, 8 30, 3 3, 63 25 39, 5 11, 1 13 1, 89 27 140 189 37, 4 12, 2 14, 1 1, 79 24 050 47 13, 7 15, 6 2, 25 24 140 191 44, 5 15, 3 17, 2 2, 12 21 060 59 16, 2 19, 6 2, 83 24 130 187 56 070 68 19, 3 24, 8 3, 23 25 119 182 64 080 80 22, 4 27, 9 3, 84 28 143 172 76 017 6 19, 1 4, 71 5, 71 0, 91 35 223 223 18, 2 5, 23 6, 23 0, 87 32 244 244 15, 2 7, 04 8, 04 0, 73 23 224 224 19, 2 9, 28 10, 3 0, 92 24 220 220 20, 8 10, 4 11, 4 0, 99 20 179 179 26, 9 14, 1 15, 6 1, 28 21 149 196 32, 3 16, 4 18, 3 1, 54 18 021 24, 1 6, 39 7, 39 1, 15 37 193 193 22, 9 7, 03 8, 03 1, 09 34 026 25, 8 7, 14 8, 14 1, 23 31 190 190 24, 6 7, 85 8, 85 1, 17 28 033 33, 5 9, 77 11, 3 1, 6 31 136 136 31, 9 10, 7 12, 2 1, 52 29 040 18, 1 21, 5 2, 77 23 21, 5 27 25, 1 30, 6 3, 75 27 34 8, 1 1, 13 36 3, 17 24 40, 9 11, 2 13, 1 1, 96 29 138 187 38, 7 12, 4 14, 3 1, 85 26 050 48, 5 13, 9 15, 8 2, 32 25 137 189 45, 9 15, 5 17, 4 2, 19 22 060 61 16, 4 19, 8 2, 92 25 127 185 58 070 70 19, 5 25 3, 34 27 115 179 66 080 83 22, 7 28, 2 3, 96 30 138 169 78 017 7 19, 8 4, 75 5, 75 0, 94 37 217 217 18, 8 5, 28 6, 28 0, 9 233 233 16, 8 6, 45 7, 45 0, 8 021 10, 8 12, 3 1, 57 31 12, 5 14, 4 1, 91 27 18, 3 21, 7 2, 85 24 21, 7 27, 2 3, 27 26 25, 4 30, 9 3, 87 28 24, 9 6, 46 7, 46 1, 19 40 186 186 23, 7 7, 1 208 208 21, 2 8, 55 9, 55 1, 01 29 204 204 22, 8 9, 55 10, 5 1, 09 24 156 156 29, 6 13 143 192 35, 6 15, 1 17 143 193 42, 1 19, 1 21 135 190 53 026 26, 7 7, 21 8, 21 1, 27 33 182 182 25, 4 7, 93 8, 93 1, 21 30 033 34, 6 9, 87 11, 4 1, 65 33 125 125 33 040 42, 3 11, 3 13, 2 2, 02 31 135 185 40 050 50 14, 1 16 2, 39 27 134 187 47, 4 15, 7 17, 6 2, 26 24 060 63 16, 6 20 3, 01 27 123 182 60 070 72 19, 8 25, 3 3, 44 29 110 176 68 080 86 23 28, 5 4, 09 32 132 165 81 Puissances frigorifiques pompe simple et pompe double Légende: LWT CAP kW COMP kW UNIT kW COOL l/S COOL kPa PRES kPa (1) PRES kPa (2) Température de sortie d'eau Puissance frigorifique Puissance absorbée par les compresseurs Puissance absorbée de l'unité (compresseurs, ventilateurs, contrôle) Débit d'eau évaporateur Perte de charge évaporateur Pression disponible à la sortie de l'unité avec module hydraulique pompe simple Pression disponible à la sortie de l'unité avec module hydraulique pompe double Facteurs de correction à pleine charge pour test en laboratoire EUROVENT: Puissance calorifique nette: 1. 000 Coefficient d'efficacité énergétique: 1. 000 Perte de charge à l'échangeur: 1. 000 Données d'application: Unités standards Réfrigérant R407C Différence entrée/sortie d'eau au condenseur: 5K Fluide au condenseur: eau Coefficient d'encrassement: 0. 44x10-4 (m2 K) / W Performances établies selon EN 255 LWT 12 35 COMP UNIT COOL COOL PRES PRES CAP COMP UNIT COOL COOL PRES PRES CAP COMP UNIT COOL COOL PRES PRES CAP COMP UNIT COOL COOL PRES PRES 30RYH 40 (1) kW kW kW l/s kPa kPa kPa kW kW kW l/s kPa kPa kPa kW kW kW l/s kPa kPa kPa (2) (1) (2) (1) (2) Température d'entrée d'air au condenseur 45 25 (1) kW kW l/s kPa kPa kPa (2) 30 CAP COMP UNIT COOL COOL PRES PRES CAP (1) (2) °C kW 220 220 18, 5 5, 89 6, 89 0, 88 33 190 190 23, 2 7, 87 8, 87 1, 11 35 186 186 24, 9 8, 79 9, 79 1, 19 29 130 130 32, 3 12 137 186 39, 1 13, 9 15, 8 1, 87 26 137 188 46, 2 17, 5 19, 4 2, 2 126 184 58 113 178 67 137 168 79 209 209 19, 7 5, 99 6, 99 0, 94 37 175 175 24, 7 8, 01 9, 01 1, 18 39 170 170 26, 6 8, 94 9, 94 1, 27 33 109 109 34, 5 12, 2 13, 7 1, 65 33 132 182 41, 6 14, 2 16, 1 1, 99 29 131 184 49 119 179 62 104 172 71 126 161 83 28, 9 34, 4 3, 98 30 137 168 78 24, 6 30, 1 3, 39 28 112 177 67 26, 9 32, 4 3, 2 20, 8 24, 2 2, 95 26 125 184 58 22, 8 26, 2 2, 78 23 25 31, 7 37, 2 3, 75 27 17, 9 19, 8 2, 34 26 136 188 46, 2 19, 6 21, 5 2, 21 23 137 186 39, 2 15, 6 17, 5 1, 87 26 126 126 32, 6 13, 3 14, 8 1, 56 30 183 183 25, 2 9, 79 10, 8 1, 2 29 188 188 23, 3 8, 77 9, 77 1, 12 35 218 218 18, 6 6, 6 7, 6 0, 89 33 28, 3 33, 8 3, 76 27 147 174 74 31 36, 5 3, 53 24 156 180 69 24, 1 29, 6 3, 2 25 121 183 63 26, 3 31, 8 3, 01 22 128 187 59 20, 4 23, 8 2, 78 23 132 188 55 22, 4 25, 8 2, 62 20 137 192 51 23 141 192 43, 5 19, 2 21, 1 2, 08 20 145 195 40, 7 21, 1 23 141 190 36, 8 15, 3 17, 2 1, 76 23 145 193 34, 6 16, 7 18, 6 1, 65 20 1, 95 18 24, 4 27, 8 2, 46 18 28, 8 34, 3 2, 83 19 33, 9 39, 4 3, 3 21 13, 5 1, 55 30 146 146 30, 6 13, 1 14, 6 1, 46 27 162 162 28, 8 14, 3 15, 8 1, 38 24 197 197 23, 6 9, 63 10, 6 1, 13 26 208 208 22, 3 10, 5 11, 5 1, 06 23 201 201 21, 9 8, 62 9, 62 1, 05 31 212 212 20, 6 9, 43 10, 4 0, 98 27 228 228 17, 4 6, 5 7, 5 0, 83 30 236 236 16, 4 7, 15 8, 15 0, 78 27 243 243 223 223 218 218 177 177 148 196 149 198 142 195 134 191 165 186 235 235 212 212 207 207 1, 47 27 18, 9 1, 76 23 24, 9 28, 3 2, 61 20 120 182 63 147 175 73 29, 3 34, 8 3, 01 22 34, 6 40, 1 3, 51 23 161 161 145 193 145 195 132 188 55 137 192 128 187 157 181 kW kW l/s kPa kPa kPa kW 017 9 1, 25 32 8 20, 4 4, 79 5, 79 0, 98 39 212 212 19, 5 5, 32 6, 32 0, 93 36 017 25, 8 6, 52 7, 52 1, 23 43 178 178 24, 5 7, 17 8, 17 1, 17 39 021 27, 6 7, 28 8, 28 1, 32 35 174 174 26, 3 8 026 35, 7 9, 97 11, 5 1, 71 35 114 114 34, 1 10, 9 12, 4 1, 63 32 033 18, 5 21, 9 2, 94 26 21, 9 27, 4 3, 38 28 25, 7 31, 2 3, 98 30 7, 31 8, 31 1, 24 44 43, 7 11, 5 13, 4 2, 09 33 133 182 41, 4 12, 7 14, 6 1, 98 29 040 52 14, 3 16, 2 2, 46 28 132 185 48, 8 15, 9 17, 8 2, 33 25 050 65 16, 8 20, 2 3, 11 28 119 180 62 060 74 20 25, 5 3, 55 31 105 173 71 070 88 23, 3 28, 8 4, 21 34 126 161 83 017 10 21, 8 4, 88 5, 88 1, 04 44 200 200 20, 7 5, 41 6, 41 0, 99 40 227 227 17, 5 7, 25 8, 25 0, 83 30 200 200 21, 9 9, 58 10, 6 1, 05 31 195 195 23, 8 10, 7 11, 7 1, 14 26 144 144 30, 7 14, 5 16 141 189 36, 8 17 021 27, 4 6, 66 7, 66 1, 31 48 162 162 26 026 12, 9 14, 8 2, 1 16, 3 18, 2 2, 47 29 18, 9 22, 3 3, 12 29 22, 4 27, 9 3, 58 31 26, 3 31, 8 4, 22 34 33 29, 3 7, 43 8, 43 1, 4 40 158 158 27, 9 8, 16 9, 16 1, 33 36 033 38 10, 2 11, 7 1, 82 40 91 91 36, 3 11, 1 12, 6 1, 73 36 040 46, 5 11, 8 13, 7 2, 22 37 127 178 44 050 54 14, 7 16, 6 2, 6 32 126 181 52 141 192 43, 5 21, 4 23, 3 2, 08 20 060 69 17, 2 20, 6 3, 29 32 111 174 65 070 79 20, 4 25, 9 3, 77 35 95 166 75 080 93 23, 9 29, 4 4, 45 38 114 153 88 Puissances frigorifiques pompe simple et pompe double (suite) Légende: LWT CAP kW COMP kW UNIT kW COOL l/S COOL kPa PRES kPa (1) PRES kPa (2) Température de sortie d'eau Puissance frigorifique Puissance absorbée par les compresseurs Puissance absorbée de l'unité (compresseurs, ventilateurs, contrôle) Débit d'eau évaporateur Perte de charge évaporateur Pression disponible à la sortie de l'unité avec module hydraulique pompe simple Pression disponible à la sortie de l'unité avec module hydraulique pompe double Facteurs de correction à pleine charge pour test en laboratoire EUROVENT: Puissance calorifique nette: 1. 000 Coefficient d'efficacité énergétique: 1. 000 Perte de charge à l'échangeur: 1. 000 Données d'application: Unités standards Réfrigérant R407C Différence entrée/sortie d'eau au condenseur: 5K Fluide au condenseur: eau Coefficient d'encrassement: 0. 44x10-4 (m2 K) / W Performances établies selon EN 255 Guide de Prescription Modèle Carrier Aquasnap 30RYH Puissance calorifique nominale: 18-78 kW Puissance frigorifique nominale: 17-76 kW 1ère partie - Généralités Pompes à chaleur air/eau réversibles pour installation intérieure équipées de compresseurs Scroll, d'un ventilateur à pression disponible, d'une régulation par microprocesseur auto-adaptative et fonctionnant avec le fluide frigorigène HFC-407C sans action sur la couche d'ozone. Assurance qualité Les 30RYH respectent les exigences des directives Européennes: - Equipement sous pression (DESP) 97/23/CE - Machine 98/37/CE modifiée, - Basse tension 73/23/CEE modifiée, - Compatibilité électromagnétique 89/336/CEE modifiée et les recommandations applicables des normes Européennes: - Sécurité des machines, équipements électriques des machines, règles générales: EN 60204-1, - Emissions électromagnétiques rayonnées: EN50081-1 - Emissions électromagnétiques conduites: EN 50081-2, - Immunité électromagnétique: EN 50082-2. Les 30RYH sont conçues, et testées dans une organisation dont le système d'assurance qualité est certifié ISO 9001. Les 30RYH sont assemblées dans une usine dont le système de gestion de l'environnement est certifié ISO 14001. Les performances annoncées sont certifiées par EUROVENT et vérifiées par des laboratoires indépendants. Toutes les unités subissent un test de fonctionnement avant expédition. 2ème partie - Produits Equipement I Echangeur à air/ventilateur I Une batterie verticale avec ailettes à persiennes en aluminium serties sur des tubes rainurés en cuivre. Protection contre l'accumulation de glace par résistance électrique sur le support batterie. I Ventilateur axial à pression disponible, pales profilées en aile d'avion pour un fonctionnement silencieux. Moteur triphasé bi-vitesses ( 24/12 r/s) isolation classe F indice de protection IP 55, protection contre la surcharge par sondes internes au moteur. Soufflage vertical avec manchette rigide de raccordement de la gaine de sortie d'air. [. . . ] Protection contre le gel jusqu'à -20°C par isolation thermique et cyclage de la pompe à eau. Nota: unité sans module hydraulique (option): tuyauteries hydrauliques internes protégées contre le gel jusqu'à -10°C par résistance électrique. Compresseur De type hermétique Scroll avec seulement 3 pièces en mouvement, moteur électrique à 2 pôles refroidi par les gaz aspirés avec protection contre la surcharge, par thermostat interne et/ou relais thermique. Voyant de niveau huile et charge d'huile de synthèse de type polyol-ester. Echangeur à eau Un échangeur à plaques en acier inoxydable brasées au cuivre. Isolation thermique par mousse à cellules fermées, protection contre le gel en fonctionnement par détecteur de débit (en standard sur toutes les versions). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CARRIER 42EACC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CARRIER 42EACC will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag