[. . . ] GT-PW (50YEW) Water-To-Water Series
WATER-TO-WATER PURON ® SYSTEMS SIZE 010 [10 kW] Revised Aug. 1 2010
GT-PW Water-to-Water (50YEW) Series Table of Contents
Unit Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 Model Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199 Rated Equipment Performance & Efficiencies . . . . . . . . . . . . . . . . . . 200 Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201-202 Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204 Electrical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206-213 Engineering Guide Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214 Accessories & Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215 Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215 Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
50YEW 196
Carrier : Turn to the Exper ts.
Carrier Geothermal Heat Pump Systems 50YEW Water-To-Water Design Features
The 50YEW series is unlike any other water-to-water heat pump on the market today. [. . . ] hx & pump* N = Cupro-Nickel Source & Braze Plate Load, No DHW P = Cupro-Nickel Source & Braze Plate Load, DHW w/Sec. hx & pump*
Controls
W = CXM Y = CXM w/VSFP
*When digit 9 = "D" or "P, " digit 7 cannot be A. "
Residential Products Technical Guide
50YEW 199
GT-PW Water-to-Water (50YEW) Series Rated Equipment Performance & Efficiencies
60 Hz (I-P) Units
Ground Loop Heat Pump Heating Model Indoor 86/95°F Outdoor 32/27°F
Capacity Mbtuh 50YEW010 THW010 32. 6 COP 4. 2
Ground Water Heat Pump Heating Indoor 86/95°F Outdoor 50/45°F
Capacity Mbtuh 42. 6 COP 5. 2
Indoor 104/113°F Outdoor 32/27°F
Capacity Mbtuh 30. 8 COP 3. 3
Indoor 104/113°F Outdoor 50/45°F
Capacity Mbtuh 39. 9 COP 4. 1
Indoor temperature is also called "Load;" outdoor temperature is also called "Source. " Numbers shown with "/" indicate entering/leaving water temperatures. Bold outline indicates typical radiant floor application temperatures. Ratings at 40°C [104°F] are based upon AHRI/ISO Standard 13256-2; all other ratings are based upon Standard EN 14511-2.
60 Hz (S-I) Units
Ground Loop Heat Pump Heating Model Indoor 30/35°C Outdoor 0/-3°C
Capacity kW 50YEW010 THW010 9. 57 COP 4. 2
Ground Water Heat Pump Heating Indoor 30/35°C Outdoor 10/7°C
Capacity kW 12. 50 COP 5. 2
Indoor 40/45°C Outdoor 0/-3°C
Capacity kW 9. 03 COP 3. 3
Indoor 40/45°C Outdoor 10/7°C
Capacity kW 11. 69 COP 4. 1
Indoor temperature is also called "Load;" outdoor temperature is also called "Source. " Numbers shown with "/" indicate entering/leaving water temperatures. Bold outline indicates typical radiant floor application temperatures. Interpolation is permissible; extrapolation is not. Operation below 40°F EWT (source) is based upon 15% methanol antifreeze solution. All performance data is based upon the lower voltage of dual voltage units. Antifreeze for source water is required for operation in the shaded area and all source EWTs below 40°F.
50YEW 202
Carrier : Turn to the Exper ts.
Carrier Geothermal Heat Pump Systems Physical Data
Model
Compressor (qty) Factory Charge HFC-410A (oz) [kg]
010
1 88 [2. 50]
Indoor/Load Water Connection Size
FPT (in) 1
Outdoor/Source Water Connection Size
FPT (in) 1
Domestic Hot Water Connection Size
FPT (in) 3/4
Maximum Working Pressure (Water Side)
Base Unit (PSIG) [kPa] DHW Option (PSIG) [kPa] Internal Source Pump* w/Expansion Tank (PSIG) [kPa] Internal Load Pump * w/Expansion Tank (PSIG) [kPa] Weight - Operating, (lbs) [kg] Weight - Packaged, (lbs) [kg] Dual isolation compressor mounting Balanced Port Expansion Valve (TXV) Insulated Source and Load Water Coils 500 [3445] 145 [999] 45 [310] 45 [310] 455 [207] 470 [214]
*Does not apply to DHW potable water circuit
Residential Products Technical Guide
50YEW 203
GT-PW Water-to-Water (50YEW) Series 50YEW Dimensions
1. 9" [4. 9cm]
2. 1" [5. 3cm]
Overall Cabinet Model A Depth in. 26. 8 68. 1 B Width 25. 6 65. 1 C Height 48. 9 124. 2
Water Connections
1
2
3 F Load (Indoor) Water In 22. 3 56. 6
4 G DHW Water Out 11. 3 28. 7
5 H Load (Indoor) Water Out 17. 7 45
6 J DHW Water In 14. 4 36. 6
Electric Access Plugs
D E Source Source (Outdoor) (Outdoor) Water In Water Out 3. 4 8. 6 8. 1 20. 6
K Low Voltage 33. 6 85. 3
L Low Voltage 35. 6 90. 4
M Power Supply 38 96. 5
010
50YEW 204
Carrier : Turn to the Exper ts.
Carrier Geothermal Heat Pump Systems Electrical Data
Units with DHW Option Model Voltage Code G Voltage Min/Max Voltage 197/254 Compressor Qty 1 RLA 20. 7 LRA 81
*Load *Source
Pump FLA 1. 07 1. 07 Pump FLA 1. 07
ISBP Pump FLA 1. 07 1. 07
Total Unit FLA 22. 8 23. 9
Min Circuit Amps 28 29. 1
Max Fuse HACR 45 45
50YEW010 THW010
208-230/60/1
Standard (No DHW) Model Voltage Code G Voltage Min/Max Voltage 197/254 Compressor Qty 1 RLA 20. 7 LRA 81
*Load *Source
Pump FLA 1. 07 1. 07 Pump FLA 1. 07
Total Unit FLA 21. 8 22. 8
Min Circuit Amps 26. 9 28
Max Fuse HACR 45 45
50YEW010 THW010
208-230/60/1
*Denotes optional items. Consult unit data plate if configuration is unknown.
Electrical - Wiring Diagram Matrix
Model
50YEW010 50YEW010 50YEW010 50YEW010
Diagram Number
96B0108N05 96B0108N06 96B0108N08 96B0108N09
Voltage
230/60/1 230/60/1 230/60/1 230/60/1
Option
VSFP DHW DHW + VSFP
Residential Products Technical Guide
50YEW 205
Electrical Wiring Diagrams GT-PW Water-to-Water (50YEW) Series 50YEW010 Electrical Wiring Diagram - 230/60/1 96B0108N05
50YEW 206
Carrier : Turn to the Exper ts.
Carrier Geothermal Heat Pump Systems 50YEW010 Electrical Wiring Diagram - 230/60/1 96B0108N05
Residential Products Technical Guide
50YEW 207
GT-PW Water-to-Water (50YEW) Series 50YEW010 Electrical Wiring Diagram - 230/60/1 VSFP - 96B0108N06
50YEW 208
Carrier : Turn to the Exper ts.
Carrier Geothermal Heat Pump Systems 50YEW010 Electrical Wiring Diagram - 230/60/1 VSFP - 96B0108N06
Residential Products Technical Guide
50YEW 209
GT-PW Water-to-Water (50YEW) Series 50YEW010 Electrical Wiring Diagram - 230/60/1 DHW - 96B0108N08
50YEW 210
Carrier : Turn to the Exper ts.
Carrier Geothermal Heat Pump Systems 50YEW010 Electrical Wiring Diagram - 230/60/1 DHW - 96B0108N08
Residential Products Technical Guide
50YEW 211
GT-PW Water-to-Water (50YEW) Series 50YEW010 Electrical Wiring Diagram - 230/60/1 DHW + VSFP - 96B0108N09
50YEW 212
Carrier : Turn to the Exper ts.
Carrier Geothermal Heat Pump Systems 50YEW010 Electrical Wiring Diagram - 230/60/1 DHW + VSFP - 96B0108N09
Residential Products Technical Guide
50YEW 213
GT-PW Water-to-Water (50YEW) Series Engineering Guide Specifications
General The water-source heating units shall be high temperature water-towater heat pumps. Units shall be performance rated in accordance with EN 14511-2 or ARI/ISO/ASHRAE 13256-2, and listed by a recognized safety-testing laboratory or agency, such as ETL. Each unit shall be water run-tested at the factory. The quality control system shall automatically perform via computer: triple leak check, pressure tests, evacuate and accurately charge system, perform detailed heating mode tests, and quality cross check all operational and test conditions to pass/fail data base. Each unit shall be pallet mounted and shipped with appropriate protective packaging to help avoid damage in transportation. The units shall be warranted by the manufacturer against defects in materials and workmanship for a period of 10 years on all parts, and 10 years on the compressor and refrigerant circuit parts with a service labor allowance for 5 years on refrigeration components and 2 years on other parts. An optional extended warranty is available for the 50YEW Series units, which increases the labor allowance to 10 years on all parts. The water source units shall be designed to operate with entering Source temperature between 20 and 110°F [-7 and 43°C], and entering Load temperature between 50 and 130°F [10 and 54°C] with a maximum leaving load temperature of 145°F [63°C]. Casing & Cabinet The cabinet shall be fabricated from heavy-gauge galvanized steel and painted with a polyester powder coating. Access door shall be hinged for easy access. The interior shall be insulated with 1/2" [13mm] thick, multi-density, foil-backed coated glass fiber. Three access panels shall be provided and shall be removable with piping in place. [. . . ] This mode shall include a factory-installed, internal secondary heat exchanger and a factory-installed potable water, bronze circulating pump. This option shall provide an additional set of water connections for the potable domestic hot water and shall be completely factory installed and wired. An external sensor shall be provided to sense the domestic water storage tank temperature. Internal Source and Load Pumps / Internal Expansion Tanks Optional Source pump(s), Load pump, and expansion tank(s) shall be factory installed and wired to help lower installation costs and labor. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CARRIER GT-PX(50YD)
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.