[. . . ] 1. 20 Software for the ALGEBRA FX 2. 0 Series
1. E-CON Overview EA-100 Setup Setup Memory Program Converter Starting a Sampling Operation
All of the explanations provided here assume that you are already familiar with the operating precautions, terminology, and operational procedures of the calculator and the EA-100.
1-1 E-CON Overview
1. E-CON Overview
· From the Main Menu, select E-CON to enter the E-CON Mode.
· The E-CON provides the functions listed below for simple and more efficient data sampling using the CASIO EA-100. Displays a screen for setting up the EA-100. [. . . ] S-G Smoothing b(5-p): 5-point d(17-p): 17-point · 3(MED) . . . . . . . Median Filter b(3-p): 3-point c(5-p): 5-point · Note that the above options appear only when real-time sampling is turned off (by pressing 2(NO) for the Real-Time item). After all the settings are the way you want, press w to return to the Advanced Setup menu. c(9-p): 9-point e(25-p): 25-point
u To configure a custom probe
You can use the procedures in this section to configure a custom probe*1 for use with the EA-100.
Creating a New Custom Probe Configuration
To configure a custom probe, you must input values for the constants of the fixed linear transformation formula (ax + b). The required constants are slope (a) and intercept (b). x in the above expression (ax + b) is the sampled voltage value (sampling range: 0 to 5 volts). You can use either of the two following procedures to create a new custom probe configuration while creating an EA-100 setup using Advanced Setup.
*1 The term "custom probe" means any sensor other than the CASIO or VERNIER sensors specified as standard for the E-CON Mode.
2-12 EA-100 Setup
· To configure a custom probe starting from the Advanced Setup menu 1. From the E-CON main menu, press 1(SETUP) and then c(Advan) to display the Advanced Setup menu. · See "Creating an EA-100 Setup Using Advanced Setup" on page 2-4 for more information. On the Advanced Setup menu, press f(Custom Probe) to display the Custom Probe List.
· The message "No Custom Probe" appears if the Custom Probe List is empty. · This displays the screen for inputting the name of the new custom probe. Input up to 18 characters for the custom probe name, and then press w. · This displays the screen for configuring a new custom probe.
5. Use the function key operations described below to make custom probe configuration settings. · To change the setting of an item, first use the f and c cursor keys to move the highlighting to the item. Next, use the function keys to select the setting you want. (1) Slope Press 1(EDIT) to display a dialog box for inputting the slope for the linear transformation formula. (2) Intercept Press 1(EDIT) to display a dialog box for inputting the intercept for the linear transformation formula. (3) Unit Name Press 1(EDIT) to display a dialog box for inputting up to eight characters for the unit name. Press wand then input a memory number (1 to 99). · This advances to the Channel parameter setting screen in step 1 under "To change Channel parameter settings" on page 2-6. From there you can continue with the EA-100 Advanced Setup procedure.
2-13 EA-100 Setup
· To configure a custom probe starting from the Channel parameter setting screen 1. [. . . ] · The message "Complete!" appears when conversion is complete.
# When you convent setup data to a CFX-9850 Series or fx-7400 Series program, any sample value storage list number greater than 5 is changed to 5.
# CFX-9850 Series or fx-7400 Series calculators support up to six lists only. # List 6 is used for EA-100 setup.
5-1 Starting a Sampling Operation
5. Starting a Sampling Operation
The section describes how to use a setup created using the E-CON Mode to start an EA-100 sampling operation.
k Before getting started. . .
Be sure to perform the following steps before starting sampling with the EA-100. In accordance with the setup you plan to use, connect the proper sensor to the appropriate EA-100 channel. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CASIO E-CON
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.