User manual CASIO E-CON2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CASIO E-CON2. We hope that this CASIO E-CON2 user guide will be useful to you.

Lastmanuals help download the user guide CASIO E-CON2.


Mode d'emploi CASIO E-CON2
Download
Manual abstract: user guide CASIO E-CON2

Detailed instructions for use are in the User's Guide.

[. . . ] E-CON2 1 2 3 4 5 6 7 8 9 10 11 E-CON2 Overview Using the Setup Wizard Using Advanced Setup Using a Custom Probe Using the MULTIMETER Mode Using Setup Memory Using Program Converter Starting a Sampling Operation Using Sample Data Memory Using the Graph Analysis Tools to Graph Data Graph Analysis Tool Graph Screen Operations All of the explanations provided here assume that you are already familiar with the operating precautions, terminology, and operational procedures of the calculator and the EA-200. 20021201 1-1 E-CON2 Overview 1 E-CON2 Overview · From the Main Menu, select E-CON2 to enter the E-CON2 Mode. E-CON2 Main Menu · "The E-CON2 Mode" provides the functions listed below for simple and more efficient data sampling using the CASIO EA-200. Displays a screen for setting up the EA-200. Displays a screen for saving EA-200 setup data under a file name. · This function converts EA-200 setup data configured by E-CON2 to a program. [. . . ] Press w and then input a memory number (1 to 99). · If you start from the final Setup Wizard screen (page 2-3), this saves the setup and the message "Complete!" appears. Press w to return to the final Setup Wizard screen (page 2-3). · If you start from the Advanced Setup menu (page 3-1) or the E-CON2 main menu (page 1-1), this saves the setup and returns to the setup memory list which includes the name you assigned it. · Since you assign both a setup name and a file number to each setup, you can assign the same name to multiple setups, if you want. k Using and Managing Setups in Setup Memory All of the setups you save are shown in the setup memory list. After selecting a setup in the list, you can use it to sample data or you can edit it. u To preview saved setup data You can use the following procedure to check the contents of a setup before you use it for sampling. On the E-CON2 main menu (page 1-1), press 2(MEM) to display the setup memory list. Use the f and c cursor keys to highlight the name of the setup you want. · This displays the preview dialog box. 4. To close the preview dialog box, press i. 20021201 6-3 Using Setup Memory u To recall a setup and use it for sampling Be sure to perform the following steps before starting sampling with the EA-200. In accordance with the setup you plan to use, connect the proper sensor to the appropriate EA-200 channel. Prepare the item whose data is to be sampled. On the E-CON2 main menu (page 1-1), press 2(MEM) to display the setup memory list. Use the f and c cursor keys to highlight the name of the setup you want. In response to the confirmation message that appears, press w. · Pressing w sets up the EA-200 and then starts sampling. · To clear the confirmation message without sampling, press i. u To change the name of setup data 1. On the E-CON2 main menu (page 1-1), press 2(MEM) to display the setup memory list. Use the f and c cursor keys to highlight the name of the setup you want. · This displays the screen for inputting the setup name. 4. Input up to 18 characters for the setup name, and then press w. · This changes the setup name and returns to the setup memory list. [. . . ] On the graph screen, press 6(g), and then 4(SPKR). · This displays the trace pointer for selecting the range on the graph. 2. Move the trace pointer to the start point of the range you want to output from the speaker, and then press w. Move the trace pointer to the end point of the range you want to output from the speaker, and then press w. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CASIO E-CON2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CASIO E-CON2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag