If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CAT EYE CC-AT100 (ALTIMETER). We hope that this CAT EYE CC-AT100 (ALTIMETER) user guide will be useful to you.
Lastmanuals help download the user guide CAT EYE CC-AT100 (ALTIMETER).
Manual abstract: user guide CAT EYE CC-AT100 (ALTIMETER)
Detailed instructions for use are in the User's Guide.
[. . . ] ®
®
Km
·· /h
·K
CC-AT100 WITH ALTIMETER FUNCTION
0 00 15 00 47 0 10 4 14 00 1 14 00 8 13 00 5 13 00 32 0 10 9 12 00 6 12 00 3 12 00 0 12
Fee
t
00 15 0 0 12 0 0 9 00 6 0 30 0 0 -300 -600 -900 0 -1200 -15
50 0 49 Me 0 ter 48 0 47 0 46 0 45 0 44 0 43 0 42 0 41 0 40 0
50 40 30 20 10 0 -10 -20 -30 -40 -50
m
/h ile
M ile ·M ··
INSTRUCTION MANUAL
E
Introduction
Thank you for purchasing CATEYE CYCLOCOMPUTER Model CC-AT100. As well as cyclocomputer function, this model has altimeter function, which measures altitude and atmospheric temperature, by sensing the changes of the atmospheric pressure with the pressure-sensor. When cycling in a hilly area with a mountain bike, it gives the current altitude (above sea level) and trip altitude gain in the 1 meter resolution. The screen is backlit for night viewing. [. . . ] Note: If the pressure changes while riding, the altitude data will give an error. Continuous Measuring Mode (Bicycle Symbol: off)
When using this unit on its own apart from a bicycle, for hiking etc. , switch off the bicycle symbol. In this way, the altitude data is always influenced by the change of the pressure (Fig. · In this mode, if the Auto (automatic start/stop) function is on, the elapsed time cannot be measured; switch off the AT symbol and operate with the S/S button in each start/stop. (Refer to "Auto Function", page 12. ) Note: As the pressure changes constantly, the altitude data will give an error to some extent. * Release the power saving function by pressing the S/S button or the Mode button.
Symbol off
Pressure change
Altitude
Affected by pressure change Stopped Lapse of time
Riding
Fig. 12
Riding
4. How to Switch on/off the Bicycle Symbol
To switch on(off) the bicycle symbol, first display the sub mode showing trip altitude gain and total altitude gain, with the operation of the Mode button, and press the Set button. Then press the Set button again, and the bicycle symbol will be switched on(off).
5. How to Correct the Current Altitude
Air pressure changes constantly, due to various weather conditions. As such, while riding, it is necessary to correct the altitude. It is recommended to make corrections whenever a reliable index (such as map or peak pointer) is available. * The basic knowledge of the altitudes of your house, public facilities, etc. will be useful information for correction.
10
How to Correct the Altitude
First display the main mode showing , with the operation of the Mode button. Press the Set button when the speed is zero, and it turns to the correction mode (Fig. 13). The figure increases with each press of the S/S button, and decreases with each press of the Mode button. To increase/ decrease the number rapidly, hold down the button. Adjust the figure to the correct altitude, and press the Set button to complete this operation.
E
Fig. 13
HOW TO USE AS A CYCLOCOMPUTER
Sensor Band B
1. Mounting to Bicycle
· Attach the magnet on the right spokes of the front wheel. The spokes must run correctly through the inside of the magnet as in Fig. · Attach the speed sensor and sensor holster with sensor bands A/B to the right fork. Choose a band that fits the fork diameter (S size for up to 24 , L for oversize). Insert the band B into the slit of the band A, and put the rubber pad inside of the band A (Fig. [. . . ] Clean it off according to "Daily Care". (If the cleaning still doesn't work, press the AC button; and reset the speed scale, temperature scale and the clock time. ) The current altitude shows incorrect data. Is the correction of the current altitude appropriately done?The current altitude is influenced by the change of the pressure. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CAT EYE CC-AT100 (ALTIMETER)
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.