User manual CATERPILLAR PF5 BROCHURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CATERPILLAR PF5. We hope that this CATERPILLAR PF5 user guide will be useful to you.

Lastmanuals help download the user guide CATERPILLAR PF5.


Mode d'emploi CATERPILLAR PF5
Download
Manual abstract: user guide CATERPILLAR PF5BROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] EPA Tier 4 Interim/EU Stage IIIB emission standards. Engine and Powertrain Innovative Electric Drive The D7E uses an innovative Electric Drive system for improved productivity and efficiency. The D7E uses 10­30 percent less fuel than the previous D7 model ­ as well as fewer parts and fluids ­ to help reduce overall owning and operating costs. All electrical components are fully sealed to safely operate in a wide range of dozing conditions. Liquid cooling ensures that the electric drive components deliver peak performance in extreme temperature conditions. [. . . ] This is a process that happens automatically, but the operator can initiate the cycle when convenient or interrupt regeneration as needed. A soot level monitor and regeneration indicator lights are integrated into the D7E dash display. Key Off Regeneration ­ Optional Key Off Regeneration allows the operator to initiate a regeneration cycle after the key has been turned off. If a cycle takes place, the engine will complete regeneration, followed by a cool down period prior to shutting down. Delayed Engine Shutdown ­ Delayed Engine Shutdown feature is available to allow the machine to cool immediately after a heavy work load or regeneration cycle. Engine Idle Shutdown Timer ­ An optional Engine Idle Shutdown timer will sound a warning and shut down the engine after the machine has been idling for a pre-set period of time. 4 Heavy duty performance for waste applications Structures The D7E's structures are purpose built of high-quality steel and box section construction. When it comes to structures, Caterpillar is thorough, with application specific, finite element analysis at initial design, followed by prototype shake table testing, and finally pilot machine testing prior to production. The results are long-life structures built for loads associated with quick directional changes, extreme slopes and heavy-duty pushing or pulling. In addition to the rugged structures found on standard Cat dozers, waste handling machines feature added guarding and striker bars to help protect the machine from debris wrapping, impact and abrasion. The D7E Waste Handler is designed from the inside out to withstand demolition debris and the hard knocks of the waste pile. Undercarriage Equipped for the job D7E waste handlers come with two undercarriage options, low ground pressure (LGP) or standard gauge. LGP machines provide flotation in soft underfoot conditions and stability on extreme slopes. Events and diagnostic codes, as well as hours, fuel, idle time and other detailed information are transmitted to a secure web based application, VisionLinkTM. VisionLink includes powerful tools to convey information to users and dealers, including mapping, working and idle time, fuel level and more. 10 Serviceability and Customer Support When uptime counts Designed for Serviceability The D7E redefines serviceability. With easy access to service points and longer service intervals, the D7E can significantly reduce total owning and operating costs. A tilt cab allows easy access to modular major components, such as generator, propulsion module, power electronics and hydraulics. The heating, ventilation and air conditioning (HVAC) system is self contained for improved performance, increased service intervals and ease of serviceability. Service points are grouped on the left side of the machine for quick and easy routine maintenance. Ground-level sight gauges provide quick and easy inspection of fluid levels. Modular final drives can be easily accessed and serviced. Ground Level Service Center The new ground level service center is accessible on the left hand fender without setting foot on the machine, giving easy access to the battery disconnect, remote engine shutdown and optional access light switches. It also houses an LED warning indicator showing that the powertrain and accessory systems are energized. When the systems are de-energized and safe for maintenance, the indicator turns off. Renowned Cat Dealer Support From helping you choose the right machine to knowledgeable ongoing support, Cat dealers provide the best in sales and service. Manage costs with preventive maintenance programs like Custom Track Service, Scheduled Oil Sampling (S·O·SSM) analysis, and guaranteed maintenance contracts. [. . . ] · Hearing protection may be needed when operating with an open cab (when not properly maintained or doors/windows open) for extended periods and noisy environment. · The exterior sound pressure level for the standard machine measured at a distance of 15 meters (49 feet) according to the test procedures specified in SAE J88 APR 95, mid-gear-moving operation, is 80 dB(A). 4 2 3 6 4 8 5 10 6 7 12 km/h mph Speed Drive Train Type AC Compressor Nominal Input Voltage AC Compressor Maximum Input Current Electric Water Pump System Nominal Input Voltage Electric Water Pump System Nominal Input Current AC Generator and Propulsion Module Voltage Electric Drive 320 Volts 12 Amps 320 Volts 5 Amps 480 Volts * Basic winch weight, mounting arrangement, hydraulic and electrical system weight. · Nominal current dependent on heat/ humidity loading on HVAC unit. · Measured with water pump operating speed of 4, 400 rpm. Measurement is 1 Amp with the water pump operating speed of 2, 100 rpm. 13 D7E Waste Handler Specifications Dimensions All dimensions are approximate 3 7 1 2 8 4 5 STD LGP 78 in 113 in 102 in 132 in 142 in 131 in 119 in 181 in 55 in 48 in 41 in 10. 6 in N/A 1187 mm 1425 mm 70 mm 472 mm 3. 68 m2 40 610 mm MS 0. 699 kg/cm2 215. 9 mm 7 2 719 mm 28 in 719 mm 24 in 9. 9 psi 8. 5 in 915 mm MS 0. 446 kg/cm2 215. 9 mm 8 2 28 in 6. 3 psi 8. 5 in 47 in 56 in 2. 75 in 18. 6 in 5, 698 in2 70 mm 472 mm 6. 31 m2 44 36 in 1032 mm 270 mm 977 mm N/A N/A 2. 75 in 18. 6 in 9, 792 in2 2286 mm 3423 mm 3200 mm 3365 mm 3505 mm 3322 mm 3450 mm 4608 mm N/A N/A 41 in 10. 6 in 38 in 90 in 135 in 126 in 132 in 138 in 131 in 136 in 181 in 6 1 Track Gauge 2 Width of Tractor over Trunnions Width of Tractor without Trunnions (std. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CATERPILLAR PF5

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CATERPILLAR PF5 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag