[. . . ] If you do, the contact points will conduct electricity, discharging the battery. Tighten the dial on the Flex-Tight bracket by hand only. Over-tightening can damage the bracket threads. When cleaning the computer, bracket and sensor, do not use thinners, benzene, or alcohol. [. . . ] (must be 3 mm) Does the magnet pass through the sensor line?Adjust the positions of the magnet and sensor.
Tm Elapsed Time
0:00'00" - 9:59'59"
Pace arrow
Indicates whether the current speed is faster ( ) or slower ( ) than the average speed.
C Cadence
0(20) - 299 rpm
Current speed
0. 0(4. 0) - 200. 0 km [0. 0(3. 0) - 125. 0 mph]
Dst Trip Distance
0. 00 - 999. 99 km [mile]
Selected Mode
Speed
Cadence
Dst2 Trip Distance-2
0. 00 - 999. 99 / 1000. 0 - 9999. 9 km [mile]
MODE
Starting/Stopping measurement
Measurements occur automatically when the bicycle is in use. During measurement, or flashes.
*1
Av Average Speed*2
0. 0 - 200. 0 km/h [0. 0 - 125. 0 mph]
Switching computer function
Pressing MODE switches function, in order, as shown on the left.
Mx Maximum Speed
0. 0(4. 0) - 200. 0 km/h [0. 0(3. 0) - 125. 0 mph]
Resetting data
To reset measurement data, display any data other than for Dst-2 and then press and hold MODE. Pressing and holding MODE with Dst-2 displayed resets Dst-2 only. The total distance is never reset.
Is there any foreign matter (which would prevent a clean contact) on the contact points of the computer and/or bracket?Check that no wire cable is worn or broken. Even with a normal appearance, it may be that a wire cable could be broken internally. Then reinitialize the computer referring to "Preparing the computer". Reinitialize the computer referring to "Preparing the computer".
Specification
Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lithium battery (CR1620) x 1 Battery life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 years (Using the battery one hour a day; the battery life will vary with the conditions of use. ) Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-bite, 1-chip microcomputer (Crystal controlled oscillator) Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Liquid crystal display Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . No contact magnetic sensor Wheel circumference range . . . . . 0100 mm - 3999 mm (Default figure A: 2096 mm, B: 2096 mm) Working temperature . . . . . . . . . . . . . . . 32 °F - 104 °F (0 °C - 40 °C) (This product will not function appropriately when exceeding the Working Temperature range. Slow response or black LCD at lower or higher temperature may happen respectively. ) Dimensions/weight . . . . . . . . . . . . . . . . . . . 1-53/64" x 1-7/32" x 19/32" (46. 5 x 31 x 15 mm) / 0. 63 oz (18 g) * The factory-loaded battery life might be shorter than the above-mentioned specification. * The specifications and design are subject to change without notice.
Standard Parts
Odo Total Distance
0. 0 - 9999. 9 / 10000 - 99999 km [mile]
Clock
0:00 - 23:59 or 1:00 - 12:59 *1 With the computer installed on the bracket, press on the three raised dots on the face of the computer. *2 If Tm exceeds approximately 27 hours or DST exceeds 999. 99 km, . E (Error) is displayed as the average speed. Reset data.
Power-saving function
If the computer has not received any signal for an hour, powersaving mode will activate and only the clock will be displayed. Alternatively, if the sensor detects a signal or MODE is pressed, the main display reappears.
#160-2090
Parts kit
#160-0280
Braket band
#160-2093
Braket/Sensor
#169-9766
Cadence magnet
Changing the computer settings [menu screen]
MENU
To bring up the menu screen, press MENU in any mode. [. . . ] * To enter the wheel size Clock setting . . . . . . . . . . To set the clock, refer to "Preparing the computer-4". Total distance manual entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Before reinitializing the computer, note the total distance. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CATEYE CC-RD200
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CATEYE CC-RD200 will begin.