User manual CHAFFOTEAUX & MAURY CELTIC 2.20FF RSC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CHAFFOTEAUX & MAURY CELTIC 2.20FF RSC. We hope that this CHAFFOTEAUX & MAURY CELTIC 2.20FF RSC user guide will be useful to you.

Lastmanuals help download the user guide CHAFFOTEAUX & MAURY CELTIC 2.20FF RSC.


Mode d'emploi CHAFFOTEAUX & MAURY CELTIC 2.20FF RSC
Download
Manual abstract: user guide CHAFFOTEAUX & MAURY CELTIC 2.20FF RSC

Detailed instructions for use are in the User's Guide.

[. . . ] COMBINATION BOILER installation (leave these instructions instructions with the User or at the Gas Service meter) Looking Good. Heating Better The CELTIC 2. 20 FF is a wall mounted, low water content fanned balanced flue appliance suitable for central heating and instantaneous hot water. The boiler is designed for sealed systems oniy and included in the appliance are the expansion vessel, circulating pump, temperature and pressure gauges, safety valve and electrical connection box. The flue which is 100 mm (4 ins) round pipe can be directed to the rear or to the left or right and can be extended to a maximum length of 3 m thus facilitating installation remote from an external wall. [. . . ] Terminal COM (P) and NO (21 - the common and normally open contacts. Before plastic cover is fiied does not foul turet fixing screw. ensure cable route Making the electrical connection See sect. 2 for the electrical supply requirements. c) Open door on left hand side of electrical box. d) Cut the cable entries to the size of the cable being used which should not be less than 0. 75 m* and must be heat resisting e) Remove cable clamp f) Connect permanent live and neutral supply to terminal Ph & N. h) Connect external controls - time clock room stat etC across terminals 6 & 7. k) Close door and secure with two screws. The length of the earth wire between the cable clamp and the terminal must be such that the live and neutral wires become taut before the earth wire if the supply cord is pulled. In the event of an electrical fault after installation preliminary electrical system checks must be carried out. Checks to ensure electrical safety should be carried out by a competant person ie. earth continuity, polarity and resistance to earth. Use only voltage free external control switching. No supply voltage should be connected to terminals 6 or 7. 13 5. ELECTRICAL CONTROLS boiler terminal Supply through : 1. 13 amp unswitched plug and socket block (terminals are not shown in same order as on boiler follow notation). remove link between terminals 6 and 7. 5. 1 Time clock - Time clock and room stat - The time clock contacts must be voltage free (remove external links). - The room stat accellerator should be connected is fitted. I) X in table indicates no earth connection in time clock. 2) * in table indicates that external links on time clock must be removed. 3) + in table indicates no `spare' connection in time clock so a connector will be required. 5. 2 Time clock and zone valves (Spring return) room thermostat cylinder thermostat 240 V 50n fused 30 amp. fuse switched boiler terminals (remove link 6-7) 14 5. 3 Programmer and zone valves 4 L N. hotwater heating ON 1OFF ON IOFF I room thermostat r---q spring return motorised valves with end switch. l- --1 i. i 1 cylinder thermostat r--1 1 /I I I L, , , b \ I L ---l I a 11 J \ I I \I ` boiler terminal block Honeywell Y plan, Satchwell flow share or Satchwell mini valves to control zones. Refer to controls manufacturers literature. [. . . ] Ensure earth connected and when positioning. insulated separator wires must pass through cut outs. 9. 17 To replace thermoelectric valve a) Remove case 8. 1 b) Remove thermocouple connection (B). c) Remove nut (A) securing thermoelectric valve (25 mm AF). e) Replace in reverse order. 9. 18 To replace solenoid valves Remove case 8. 1 Withdraw plugs - colour coded - from solenoids (B). Remove 6 screws (A) securing valve mounting plate. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAFFOTEAUX & MAURY CELTIC 2.20FF RSC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAFFOTEAUX & MAURY CELTIC 2.20FF RSC will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag