User manual CHAMBERLAIN ART300K

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CHAMBERLAIN ART300K. We hope that this CHAMBERLAIN ART300K user guide will be useful to you.

Lastmanuals help download the user guide CHAMBERLAIN ART300K.


Mode d'emploi CHAMBERLAIN ART300K
Download
Manual abstract: user guide CHAMBERLAIN ART300K

Detailed instructions for use are in the User's Guide.

[. . . ] This safety alert symbol means "Caution" - failure to comply with such an instruction involves risk of personal injury or damage to property. This gate drive mechanism is designed and tested to offer appropriately safe service provided it is installed and operated in strict accordance with the following safety rules. Incorrect installation and/or failure to comply with the following instructions may result in serious personal injury or property damage. Do not wear rings, watches or loose clothing while servicing or installing a gate opener. [. . . ] it should not be continuously exposed to direct sunlight. The electronic equipment enables the pull and push forces to be set with great accuracy. If installed and set correctly, the gate/door can be stopped manually. When in motion, the gate/door can be stopped at any time by operating the remote control, the push-button or the key-operated switch. The cable leading from and to the control unit must be suitable for laying outdoors and, if required, run through ducts. 230 volt wiring and low-voltage lines may not be run via the same cable. Generally speaking, the following minimum cable cross-sectional areas must be adhered to: 100-230Volt 1. 5mm2 or more Tips: Bell wire is often problematic in practical use because it loses too much voltage if long lengths of wire are used. Motor cable and light barrier cable, especially in the case of key-operated switches and ON switches (from the house wiring system) to prevent interference where long lengths of cable are used. For steel gates, fixings should be welded on or through bolted. When through bolting the gate, use large washers or a plate on the other side. the drive mechanism exerts an extremely high force on this joint. Fixings must be through bolted for wooden gates. Wood deflects under load and the bolt will become loose. Due to movement caused by repeated loading, the wood deflects more and more until the gate no longer closes correctly and has to be repaired. The arm should not be mounted while fully extended (see Fig. The unit should be mounted with an offset of about 90 degrees. If the arm's point of contact is further to the outside, it will require less room at the side but it will be harder to drive. With finger-tight thumb-screws), and check the mounting position by opening the gate manually. Description of terminal occupancy Mains cable connection: Terminal 1 N (blue) Terminal 2 PE (green/yellow) Terminal 3 L1 - 230 V (black) Flashing lamp connection: Terminal 4 L (230V) Terminal 5 L Motor connections: First motor (M1): L1 direction of OPEN (brown/black) (+ capacitor) N (blue) L1 direction of CLOSED (black/brown) (+ capacitor) Second motor (M2): L1 direction of OPEN (black/brown) (+ capacitor) N (blue) L1 direction of CLOSED (brown/black) (+ capacitor) Infrared light barrier photocell (NC) active when closing COM photocell (NC) active when opening (without light barrier - jumper between 12, 13 and 14) Emergency stop function COM Stop (NC) with emergency stop switch jumper between 15 and 16 External push-button External push-button (NO) motor 1 (pedestrian function) COM External push-button (NO) motors 1+2 (complete opening) Electric lock connection Distribution voltage 12 V AC Distribution voltage 12 V AC Connection for additional equipment & light barrier: Distribution voltage 24 V AC (500 mA max. The internal limit switch of the ART turns the drive off when the preset point is reached. Remove the cover of the drive unit, and turn the cam until the desired end point has been reached. [. . . ] Please bear in mind the power requirement of the electric lock you use. Secondary fuse for logic circuitry: push-buttons, emergency stop, light barrier, receiver. Up to 15 remote controls can be programmed on each self-learn channel. In the case of large installations it is advisable for organizational reasons, to use an external receiver or a key-operated switch or a code lock, which should be installed at the entrance. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN ART300K

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN ART300K will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag