User manual CHAMBERLAIN CB24

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CHAMBERLAIN CB24. We hope that this CHAMBERLAIN CB24 user guide will be useful to you.

Lastmanuals help download the user guide CHAMBERLAIN CB24.


Mode d'emploi CHAMBERLAIN CB24
Download

You may also download the following manuals related to this product:

   CHAMBERLAIN CB24 MANUAL 2 (14850 ko)

Manual abstract: user guide CHAMBERLAIN CB24

Detailed instructions for use are in the User's Guide.

[. . . ] Electronic Control, when installed and maintained according to all the Manufacturer's instructions in combination with a Gate, which has also been installed and maintained according to all the Manufacturer's instructions, meets the provisions of EU Directive 89/392/EEC and all amendments. I, the undersigned, hereby declare that the equipment specified above and any accessory listed in the manual conforms to the above Directives and Standards. 9 When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock. [. . . ] Batteries if installed function as back-up to open the gate in case of a power outage. Transformer must be removed from the backside of the control board if batteries are installed. POWER IN The 24Vac input can accept a charging transformer or the run transformer. Ideally the charge transformer is installed at the house and a low voltage line is used to the control board at the gate. SOLAR PANELS Optional solar panels may be used to charge the batteries. RED LED should be "Off" or indicate a fault to resolve (Example: Photocell activated or shortened wire). Red Edge for closing Red Edge/photo for opening Red Photo for opening Red Photo for closing Red Accessory current overload Red COM overload Red Timer to close run indicator Red Open gate command Red Open gate command Red Reset Function button Green Stop Button Green Logic board general power Green Shadow loop Green Interrupt loop Red Charger Overload Red Battery fuse open Red Accessory overload Red Gate 2 Limit indicator Red Gate 2 Limit indicator Red Gate 1 Limit indicator Red Gate 1 Limit indicator Red E-Lock/Maglock relay indicator Red Alarm/Flashing light relay indicator Green Diagnostic (see troubleshooting section) Red Transmitter learn indicators Red Open/Close programming indicator NOTE: When setting switches S2-5 the save switch must be in the off position prior to setting or changing switches for the change to be saved. Connect gate that opens first to terminal "Gate 1", the other to terminal "Gate 2". Repeat steps 1 and 2 until all remotes are programmed (50 remotes maximum total). Press LEARN XMITTER button (LED will light up) and hold until LED is off. NOTE: For highest level of security, we recommend the Rolling Code line of products. XMITTER button 2 will open both gates with one command from the remote control. A jumper wire is factory installed between the stop and common input. Stop (N/C) - Stop only (does not reset alarm) SBC (Single Button Control) Input (N/O) This input will command the gate to OPEN !Open (N/O) - Opens only or reverses a closing gate Open Input and Exit Loop These terminals are intended for use as a general open control. Accessories such as telephone entry systems, radio receivers (open only applications), exit loop detectors, keypads and 7-day timers may be wired to this input. Shadow Loop Input Terminal and Common This input protects cars by preventing the gate from moving off of the open or close limit when the shadow loop input is active. Activating this input while the gate is opening will have no effect. Terminal P8 ­ Open Edge or Photo Eye If an Open Edge device or a Retro-Reflective Photo Eye has been connected to Terminal P8, then this input will reverse an opening gate for 2 seconds then stop. Activating this input with an Open Edge device or a Retro-Reflective Photo Eye connected to Terminal P8 while the gate is closing will have no effect. If a Chamberlain Pulsing Photo Eye has been connected to Terminal P8, then this input will pause an opening gate until the obstruction has been removed. Upon removing the obstruction, the gate will continue to open. [. . . ] Reset system by achieving the Stop/Reset with a wire bridge momentarily. MOTOR DOES NOT RUN Relays `click' when Radio or SBC signal is given, but the operator does not move. The force setting may need to be adjusted in cold weather, as the gate will not move as freely. 1) Battery voltage low or near low voltage cut-off. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN CB24

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN CB24 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag