Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CHAMBERLAIN CPWR. We hope that this CHAMBERLAIN CPWR user guide will be useful to you.
Lastmanuals help download the user guide CHAMBERLAIN CPWR.
Detailed instructions for use are in the User's Guide.
[. . . ] Turn screws counterclockwise 1/4 turn and remove front cover. Before or while touching the circuit board, discharge any static electricity: (1) Use a grounding strap OR (2) Touch a cold, grounded, metallic pipe. The output code format switch settings are factory-set for the 30-bit format (Figure 2). [. . . ] Facility Code Factory Setting = All OFF (switches set to left).
INSTALLATION AND WIRING
1. Mount receiver to surface using #6 hardware (not provided). (Figure 8) NOTE: Mount receiver with 18" of space above the receiver for the antenna. The receivers should be installed at least 5' apart to avoid "cross-talk". Screw on antenna clockwise and slide rubber boot down to meet o-ring (Figure 7). Remove the terminal block from J2 on the circuit board. Connect wires from the CPWR 6-pin connector to the access control system (Figure 8). Then re-insert the terminal block onto J2. Wire the CPWR to the access control systems' card reader port. Refer to the access control system's instructions for appropriate wiring detail. A typical wire connection might resemble the following: CABLE SIGNALS LED DATA 1 DATA 0 +12VDC COMMON (GND) SHIELD WIRE COLOR BROWN WHITE GREEN RED BLACK SHIELD The outside of the antenna connector is not ground. If using an extension kit, do not allow it to contact a metal object.
Figure 7
U1
C2 2
Y2 L3
C9
C13 R1
L1 C17 L2 C10 C11
J1
C14
Y1 E1 D11
C9
C23 C20 C18 Y4
C15 C33 C34 C12 C16 R5 C19 R4 U6 R10 C27
L4
R22
Y3
C21
C2
SIGNAL
D12 D13
C26
1
C29
DA A T
C25
14 U2
R21
C2
R2 R3 R7
R24
R23
A VLID
D9
Mounting Holes
R6 Q4 R11
CLOCK IN
1
U7 R25 R26
TP4
POWER
D1
GRANTED
C3
U5 FACILITY
1 C5 CO D E
6 4 2 0 7 5 3 1
TP1
R8
C28 R12
DATA IN
FORMAT 3 2 1 0 Q1 3 2 BUTTON 1
C30 C31
14 U3
J3
+5V GND TP3 U12
Mounting Holes
NOTE: At power up, the CPWR will perform a system check and produce a series of LED flash sequences (this is normal).
1
15 14 13 12 11 10 9 8 C4
Q2 R19
D7 D6 D5
R20
TP2 C32
FFC
D2
U9 14 RP2 1
U4
C7
U10 RP3 1
C8
U8 RP1 1
C6
D8 D3
R17 R16 R14
R13 D3 R15
D16
MADE
SENTEX SYSTEMS
I N USA
R10
D4
J2 To Access Control Circuit Board (Reader Port)
Figure 8
3
TESTING AND TROUBLESHOOTING
1. Ensure that the red POWER LED is lit (Figure 9). If not, check your power connections and/or source. Voltage reading should be within the range of 9VDC 18VDC. The SIGNAL LED (Figure 9) should be flickering continuously, indicating that the RF receiver circuitry is operating. Press the transmitter button previously set in step 4, page 3, within view of the receiver. If the DATA-yellow and VALID-green LEDs do not light, review the Setting the Switches and Connect Signal/Power Wires sections. [. . . ] Attach front cover of receiver by turning screws clockwise 1/4 turn. Call your local power company if interference is due to arcing power lines.
U1 C22
Y2 L3
C9
C13 R1
L1 C17 L2 C10 C11
J1
C14
Y1 E1 D11
C9
C23 C20 C18 Y4
C15 C 33 C 34 C12 C16 R5 C19 R4 U6 R1 0 C27
L4
R 22
Y3
C21
C2
SIGNAL
D12
R 23
C 26
1
C29
DATA
D13
14 U2
R7 U7 R6 Q 4 R11
R2 1
C25 C2
R2 R3
R2 4
VALID
D9
POWER
D1
CLOCK IN
1
R25 R 26
TP4
GRANTED
C3
U5 FACILITY
1 C5 CO D E
6 4 2 0 7 5 3 1
TP1
R8
C28 R12
DATA IN
FORMAT 3 2 1 0 Q1 3 2 BUTTON 1
C30 C31
14 U3
J3
+5V GND TP3 U12
1
15 14 13 12 11 10 9 8 C4
14 RP2
Q2 R19
D7 D6 D5
R20
TP2 C32
FFC
D2
U9 1
C7
U10 RP3 1
C8
U8 RP1 1
C6
D8 D3
R17 R16 R14
R13 D3 R15
U4
D16
MADE
SENTEX SYSTEMS
I N USA
D11
SIGNAL
D12
DATA
D13
VALID
D9
POWER
D1
GRANTED
Figure 9
4
R 10
D4
APPENDIX: FACILITY CODE SWITCH SETTINGS
Refer to Figure 1 on page 1 for the facility code DIP switch location. Also, when setting the receiver's DIP switches, refer only to the numbers silk screened on the PC board (not the numbers on the DIP switch itself).
FC 5 4 3 2 1 0
000 0 0 0 0 0 0
001 0 0 0 0 0 1
002 0 0 0 0 1 0
003 0 0 0 0 1 1
004 0 0 0 1 0 0
005 0 0 0 1 0 1
006 0 0 0 1 1 0
007 0 0 0 1 1 1
008 0 0 1 0 0 0
009 0 0 1 0 0 1
010 0 0 1 0 1 0
011 0 0 1 0 1 1
012 0 0 1 1 0 0
013 0 0 1 1 0 1
014 0 0 1 1 1 0
015 0 0 1 1 1 1
FC 5 4 3 2 1 0
016 0 1 0 0 0 0
017 0 1 0 0 0 1
018 0 1 0 0 1 0
019 0 1 0 0 1 1
020 0 1 0 1 0 0
021 0 1 0 1 0 1
022 0 1 0 1 1 0
023 0 1 0 1 1 1
024 0 1 1 0 0 0
025 0 1 1 0 0 1
026 0 1 1 0 1 0
027 0 1 1 0 1 1
028 0 1 1 1 0 0
029 0 1 1 1 0 1
030 0 1 1 1 1 0
031 0 1 1 1 1 1
FC 5 4 3 2 1 0
032 1 0 0 0 0 0
033 1 0 0 0 0 1
034 1 0 0 0 1 0
035 1 0 0 0 1 1
036 1 0 0 1 0 0
037 1 0 0 1 0 1
038 1 0 0 1 1 0
039 1 0 0 1 1 1
040 1 0 1 0 0 0
041 1 0 1 0 0 1
042 1 0 1 0 1 0
043 1 0 1 0 1 1
044 1 0 1 1 0 0
045 1 0 1 1 0 1
046 1 0 1 1 1 0
047 1 0 1 1 1 1
FC 5 4 3 2 1 0
048 1 1 0 0 0 0
049 1 1 0 0 0 1
050 1 1 0 0 1 0
051 1 1 0 0 1 1
052 1 1 0 1 0 0
053 1 1 0 1 0 1
054 1 1 0 1 1 0
055 1 1 0 1 1 1
056 1 1 1 0 0 0
057 1 1 1 0 0 1
058 1 1 1 0 1 0
059 1 1 1 0 1 1
060 1 1 1 1 0 0
061 1 1 1 1 0 1
062 1 1 1 1 1 0
063 1 1 1 1 1 1
5
LIMITED WARRANTY
LiftMaster warranties the receiver against original manufacturing defects for a period of three (3) years, measured from the day of initial shipment by LiftMaster. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN CPWR
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN CPWR will begin.