User manual CHAMBERLAIN CSW200UL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CHAMBERLAIN CSW200UL. We hope that this CHAMBERLAIN CSW200UL user guide will be useful to you.

Lastmanuals help download the user guide CHAMBERLAIN CSW200UL.


Mode d'emploi CHAMBERLAIN CSW200UL
Download

You may also download the following manuals related to this product:

   CHAMBERLAIN CSW200UL INSTALLATION (4784 ko)

Manual abstract: user guide CHAMBERLAIN CSW200UL

Detailed instructions for use are in the User's Guide.

[. . . ] OWNER'S MANUAL CSW200ULTM V E H I C U L A R S W I N G G AT E O P E R AT O R THE CSW200ULTM IS FOR USE ON VEHICULAR PASSAGE GATES ONLY AND NOT INTENDED FOR USE ON PEDESTRIAN PASSAGE GATES. INTENDED FOR PROFESSIONAL INSTALLATION ONLY. UL325 UL991 compliant compliant TAblE Of cONTENTs sPEcIfIcATIONs ANd wARNINgs Mechanical Overview and Specifications . 5 Suggested Entrapment Protection Device Locations . 8 Electrical INsTAllATION When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of SERiOuS iNjuRy or DEATh if you do not comply with the warnings that accompany them. [. . . ] Key switch is for property owner's emergency access ONLY. DO NOT FOR USE FOR A EMERGENCY FIRE/POLICE KEY ACCESS. Contact your local Fire/Police municipalities for more information on correct Fire/Police emergency key access. Manual One-button Push and HOLD button to Open. Push button again and HOLD to Close. Manual Three-button N. O. Com Com Com key switch Turn and HOLD key to Open. Push and HOLD a button to operate. dc2000TM Entrapment Protection devices it is recommended using separate entrapment protection devices to maintain gate safety when the DC2000TM is needed for any reason. The entrapment protection devices connected to the OmniControlTM board and surge suppressor WILL NOT protect the gate when there is a AC power failure and the DC2000TM is used. (See Accessories for part number. ) 3 Edge sensor CENTER SAFETY EXIT DC-BACKUP DC-BACKUP W4 GBA MS LINK SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN REVERSE SENSOR ALARM SENSOR OFF OPEN LEFT ON OPEN RIGHT MADE IN USA COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE POWER OVERLOAD EXIT STOP SENSOR ALARM SENSOR ALARM OmniControlTM Board Sensor Connection +12Vdc 12Vdc failsafe Photoelectric sensor 123 456 7 Ground Failsafe Photoelectric Sensor: if a photoelectric sensor is not working, loses power or photoelectric sensor is blocked, then the photoelectric sensor will stop all gate operation. 22 Plug-IN lOOP dETEcTOR wIRINg Plug-In Loop Detectors (Sold individually) The wire MuST be twisted together 6 twists per foot from the end of the loop to the control board. Series Connected Outside Safety Loop Center Loop Inside Safety Loop To AVOiD damaging control board, disconnect all power to operator before installing plug-in loop detectors. use a different frequency for every loop detector installed. Exit Loop Plug-In "Center" Loop Detector: Allows gate to stay open when vehicles are obstructing path. Caution: This option is for all vehicles including ones less than 14 feet long. Center loop system requires two safety loops. (See "installing insulated Loop Wire" on next page for more information. ) Plug-In "Safety" Loop Detector: Allows gate to stay open when vehicles are obstructing path. Caution: Suggested for vehicles 14 feet or longer. if the "Inside" and "Outside" safety loops are connected to the same loop detector: · They should be series connected to the detector. · have the same number of wire turns. Example of a inside and outside 2 wire turn loop connected in series. (See "installing insulated Loop Wire" on next page for more information. ) Plug-In "Exit" Loop Detector: Allows gate to automatically open for exiting vehicles. (See "installing insulated Loop Wire" on next page for more information. ) NOTE: Refer to the plug-in loop detector manual for more specific information. Contact your local dealer for information about plug-in loop detectors. 23 110Vac EXTERNAL LOOP DETECTOR WIRING (Sold Individually) 110Vac "Center" Loop Detector: Allows gate to stay open when vehicles are obstructing path. Caution: This option is for all vehicles including ones less than 14 feet long. Center loop system requires two safety loops. Center Loop 110Vac "Safety" Loop Detector: Allows gate to stay open when vehicles are obstructing path. [. . . ] Make sure all wire connections are securely fastened. Schedule periodic maintenance on operator by qualified service technician. inquire about Manufacturers "operator warranty. " (Warranty Card included with operator. ) 19. inquire about separate "installation warranty" with installer. Installer Company Name, Address and Phone Number Date Installed: 51 Warranty Policy 7 YEAR RESIDENTIAL / 5 YEAR COMMERCIAL CSW200ULTM LIMITED WARRANTY The Chamberlain Group, inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN CSW200UL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN CSW200UL will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag