C2 Wiring
See page 7 for other wiring configurations
OWNER'S MANUAL
EGJ
EUROPEAN STYLE GEARHEAD DAMP ENVIRONMENT JACKSHAFT
TH
E C EL HA MH MB UR ER ST, LA IL IN G LIN R OIS OU 60 P, IN 12 C. 6
41 B6
PL
LIS
AC E RA TI NG LA BE L HE RE
TE
D
DO
OR
OP ER AT OR
2 YEAR WARRANTY
NOT FOR RESIDENTIAL USE
Serial # Box Installation Date Wiring Type
TABLE OF CONTENTS
SPECIFICATIONS
Operator Specifications . . 9 DIAGRAMS
1 Phase Schematic Diagram . . 4 Entrapment Protection Accessories (Optional) . [. . . ] Be sure that the power supply is of the correct voltage, phase, frequency, and amperage to supply the operator. Refer to the operator nameplate on the cover. IMPORTANT NOTE: For best protection against the environment follow directions below for required specifications for power and control wiring connections. system can be achieved, and optimum performance ensured, by adherence to simple conduit preparation and assembly techniques: 1. Square off ends of conduit by cutting the end of the conduit squarely using a hacksaw or similar tool, conduit manufacturers sometimes offer cutting jigs for this purpose. Insert conduit flush with the fitting end stop. A compression gland nut, when provided as part of a fitting, will typically achieve maximum securement. Ensure conduit jacket is not cut or ripped in any location along its surface. NOTE: For conduit preparation, always follow the conduit manufacturer's instructions.
CIA
CONDUIT & FITTINGS
ADVERTENCIA ADVERTENCIA entry hole to be placed in enclosure and Liquid tight Flexible Non-metalics Conduit (LFNC) is required for 1. Select proper fitting
use in both exposed and concealed areas and for electrical systems that require flexibility and protection from vapors, liquids or solids. LFNC conduit should be used for liquid tight environment as stated by NEMA guidelines. All conduit and conduit fittings should be marked as "Liquid Tight" conduit and fittings marked "Rain Tight" or "Wet Locations" are not to be automatically considered liquid tight. NOTE: Select all conduit and conduit connectors based on local code and application of job. Slide threaded body into fitting hole in enclosure, 3. Insert gasket around threaded area and secure in place with nut provided. (Refer to manufacturer specifications for proper torque requirements. ) 4. Remove all resulting debris created by entry hole(s) otherwise electrical components and operation may be affected.
TH E C EL HA M MB HU E RS RLA T, IL IN G LI NO ROU I S P, 6 0 IN 12 C. 6
ATTACHMENT TO ENCLOSURE
N
WARNING Do Not Run Power & Control Wiring in the Same Conduit 7
41 B6
PL AC ER
LI ST ED
AT I NG LA B EL H
DO OR
ER E
OP ER AT OR
CONTROL WIRING
DETERMINE WIRING TYPE
Refer to the wiring diagram located on the inside cover the electrical box to determine the type of control wiring.
WIRING TYPES
Standard C2 or B2 Wiring Standard operators are shipped from the factory with jumper set for C2 wiring, which requires constant pressure on button to close the door. If momentary contact on close direction is desired (B2 wiring) you must include an entrapment protection device. Constant pressure on close (C2 wiring) Red jumper wire was placed on terminal #2 in electrical enclosure. The operator will require constant pressure on close control in order to keep door moving in the close direction. Momentary contact on close (B2 wiring) Move red jumper wire from terminal #2 to terminal #3. [. . . ] · ALL power and control wiring MUST be run in separate conduit.
ENT MANUAL DISCONNECT
AVERTISSEMENT AVERTISSEMENT
Disengagement Lever
By turning the disengagement lever the gear unit can be disconnected from electric operation in order to permit manual operation of the door. For operating the lever from above floor level, attack a rope or a chain in the holes at the ends of the lever. The movement of the lever acts upon a safety micro switch, which will keep the control current disconnected until the lever has been turned absolutely perfectly into its position for normal electric operation of the door.
To Engage Pull Handle
CIA N
ADVERTENCIA ADVERTENCIA
To Disengage Pull Handle
14
WARNING CAUTION
MAINTENANCE SCHEDULE
WARNING WARNING
Check at the intervals listed in the following chart.
To avoid SERIOUS PERSONAL INJURY or DEATH from electrocution, disconnect ALL electric power BEFORE performing ANY maintenance.
ITEM Drive Chain
PROCEDURE Check for excessive slack. Lubricate. * Check & tighten as required
EVERY 3 MONTHS
EVERY 6 MONTHS
EVERY 12 MONTHS
Sprockets Check AVERTISSEMENT set screw tightness Fasteners
AVERTISSEMENT AVERTISSEMENT
ATTENTION Bearings & Shafts
Manual Disconnect
Check & Operate Check for wear & lubricate
Use SAE 30 Oil (Never use grease or silicone spray). [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN EGJ
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.