User manual CHAMBERLAIN EL25 QUICK GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CHAMBERLAIN EL25. We hope that this CHAMBERLAIN EL25 user guide will be useful to you.

Lastmanuals help download the user guide CHAMBERLAIN EL25.


Mode d'emploi CHAMBERLAIN EL25
Download
Manual abstract: user guide CHAMBERLAIN EL25QUICK GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] ® TM Quickstart EL25 Keypad Programming Guide Telephone entry/access control system with a 25 directory code capacity This Quickstart Guide is intended to highlight some applications. These instructions are not intended to be comprehensive. Please consult the Keypad Programming Manual for complete information. © 2005 The Chamberlain Group, Inc. All Rights Reserved Guide for Programming the EL25 Programming Number Description of Task Entering Programming Mode Exiting Programming Mode Change or Verify the Unit's Password Set Unit ID Number and No. [. . . ] Then (#) Internal Keypad is ALWAYS Assigned to External Access Control Device Number 0 3 Enter External Access Control Device Type (0-2). Then (#) 0 = Not Activated/No Device Assigned 1 = (Wiegand) Card Reader or Keypad Only 2 = RF Receiver 4 Assign a Door Number (1-4) to the Device. Then (#) Note: A "Door Number" is a number you assign to each external access control device. Example A: 1 2 3 4 Device "1" is a Radio Receiver and Assigned as Door "3". Example B: 1 2 3 4 Device "3" is a Card Reader or Keypad and Assigned as Door "4". Page 12 Step 2 Set Each "Relay Mode" to get the Appropriate Response: 65 There are 5 different relay modes. The Relay Mode determines what the response will be when a valid access code is entered (open a door, turn on an alarm, turn on a light then turn it off, turn on a CCTV, etc. ). Factory Setting: All Relays are Set at "1 - Strike" 1 Press Then 3 1 Important: Allthroughepsmust be performed for EACH Relay assigned to the unit. 2 Enter the Relay Number (1-4). Then (#) EL25 SetUp "Your Settings" 3 Enter Relay Mode (0-5). Then (#) 0 = Not Used 3 = CCTV - activates system's optional camera. 4 = Alarm - activates another device (siren). 1 = Strike - controls a door/gate by unlocking/opening it. 2 = Shunt - bypasses the alarm under normal circumstances. 5 = Control - controls another device (on/off light). EL25 SetUp "Your Settings" Example: 1 2 3 Assigns Relay "2" as a Shunt Relay Step 3 Set Each Relay's "Activation Time": 66 This is the amount of time (in seconds) the relay remains activated. This will define the amount of time a door cycles (unlocks, then relocks) or how long the CCTV camera remains on after being activated. Factory Setting: All Relays are set at 10 seconds 1 Press Then 3 1 Important: Allthroughepsmust be performed for EACH Relay assigned to the unit. 2 Enter the Relay Number (1-4). Then (#) 3 Enter Activation Time (1-300 Seconds). Then (#) Example: 1 2 3 When Activated, the Relay Number "4" will activate for "30" seconds. Note: A relay that controls a gate operator must be set to activate for 2 seconds. Step 4 Assign "Each" Door Number to One or More Relays: 61 When a valid access code is used at an external access control device (Door), the EL25 can be set to activate one or more relays. Factory Settings: Door 1 Activates Relay 1; Door 2 Activates Relay 2; Door 3 Activates Relay 3; Door 4 Activates Relay 4 1 Press Then 3 1 Important: Allthroughepsmust be performed for EACH Door Number assigned to the unit. 2 Enter Door Number (1-4). Then (#) 3 Enter Relays to be Activated (0000-1111). Then (#) 0 = Deactivate , 1 = Activate (1st digit=Relay 4, 2nd digit=Relay 3, etc. ) Relay 4 Relay 3 Relay 2 Relay 1 Example: 1 2 Deact Deact Activate Activate 3 When a Resident uses a Valid Code at "Door 1", Relay "1" and Relay "2" will Activate. Page 13 "Your" Door Settings Device Location Door No. Relay Relay Mode (See Tables below for reference) Relay Function Relay Activation Time (Seconds) EL25 SetUp "Your Settings" EL25 SetUp "Your Settings" When "Your Door Settings" or "Door 1, 2, 3 or 4" are referenced throughout this guide, this completed chart will outline how your EL25 system will function. Sample: EL25 Controlling 1 Door (Page 16) Device Main Keypad Front Door (REX) Exit Request Door 1 Location Door No. Relay Relay Mode 1 2 3 4 Strike Shunt Alarm CCTV Relay Function Unlocks Door Bypasses/Signals Alarm Sounds a Siren Activates Camera Relay Activation Time (Seconds) 10 sec. 10 sec. Sample: EL25 Controlling 2 Doors and a Vehicle Gate (Page 16) Device Main Keypad and Postal Lock Security Light Wiegand Card Reader Transmitter Location Front Door Back Door Gate Operator Door No. Door 1 Door 2 Door 3 Relay Relay Mode 1 2 3 4 Strike Control Strike Strike Relay Function Unlocks Door Turns on Security light Unlocks Door Opens Gate Relay Activation Time (Seconds) 10 sec. 10 sec. Sample: EL25 Controlling 4 Doors (Page 17) Device Main Keypad Wiegand Keypad Wiegand Card Reader Wiegand Card Reader Location Front Door (Entrance) Front Door (Exit) Back Door Manager's Door Door No. Door 1 Door 2 Door 3 Door 4 Relay Relay Mode 1 2 3 4 Strike Strike Strike Strike Relay Function Unlocks Door Unlocks Door Unlocks Door Unlocks Door Relay Activation Time (Seconds) 10 sec. 10 sec. Sample: EL25 Controlling Single Family Residence (Page 18) Device Main Keypad and (REX) Exit Request Wiegand Card Reader CCTV Location Driveway Pedestrian Gate In EL25 Door No. Door 1 Door 2 Door 3 Relay Relay Mode 1 2 3 4 Strike Control Strike CCTV Relay Function Opens Vehicular Gate Turns on Security Light Unlocks Pedestrian Gate Activates Camera Relay Activation Time (Seconds) 10 sec. 10 sec. Sample: EL25 Controlling Multi-Resident Apartment (Page 19) Device Main Keypad Transmitter and REX Exit Device Wiegand Card Reader Siren Location Front Door (Entrance) Vehicular Gate Pool Gate Front Door (Entrance) Door No. Door 1 Door 2 Door 3 Door 4 Relay Relay Mode 1 2 3 4 Strike Strike Strike Shunt Relay Function Unlocks Door Unlocks Door Unlocks Door Bypasses/Signals Alarm Relay Activation Time (Seconds) 10 sec. 30 sec. Page 14 Your System Layout How your system has been wired is an important part of programming it. [. . . ] Residents enter their assigned entry code onto the unit's keypad to prompt the system to grant access. Facility Code - A code that allows access cards/transmitters to be associated with a facility or complex. This allows you to manage more than one complex. You may also assign a default facility code if a group of access cards/transmitters will share the same code. Glossary B Glossary Glossary C D E F Continued on next page Page 22 Glossary G complex, normally a gate or door. Gate or Door - Used synonymously throughout the manual, these terms refer to controllable entry/exit areas of the H Holiday Schedules - Holiday schedules will modify fixed schedules for selected holiday dates. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN EL25

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN EL25 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag