User manual CHAMBERLAIN GT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CHAMBERLAIN GT. We hope that this CHAMBERLAIN GT user guide will be useful to you.

Lastmanuals help download the user guide CHAMBERLAIN GT.


Mode d'emploi CHAMBERLAIN GT
Download

You may also download the following manuals related to this product:

   CHAMBERLAIN GT 1998 (5708 ko)
   CHAMBERLAIN GT SERIES B (331 ko)
   CHAMBERLAIN GT SERIES 3000 (802 ko)
   CHAMBERLAIN GT LOGIC 3 2008 (4991 ko)
   CHAMBERLAIN GT SOLID STATE 1994 (766 ko)
   CHAMBERLAIN GT REPLACEMENT PARTS (1700 ko)
   CHAMBERLAIN GT LOGIC CONTROL V2.0 2000 (4284 ko)

Manual abstract: user guide CHAMBERLAIN GT

Detailed instructions for use are in the User's Guide.

[. . . ] FACTORY SET C2 Wiring See page 8 for other wiring configurations OWNER'S MANUAL MODEL GT INDUSTRIAL DUTY DOOR OPERATOR 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date Wiring Type NOT FOR RESIDENTIAL USE 41B6 LISTED DOOR OPERATOR SPECIFICATIONS MOTOR TYPE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Continuous duty HORSEPOWER:. . . . . . . . . . . . . . . . . 1/2, 3/4, 1 & 1-1/2 Hp Single or Three phase SPEED:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1725 RPM VOLTAGE: . . . . . . . . . . . . . . . . . . . . . . . . . . 115, 220, 230 Single phase 230, 460, 575 Three phase CURRENT: . . . . . . . . . . . . . . . . . . . . . . . . . See motor nameplate ELECTRICAL TRANSFORMER:. . . . . . . . . . . . . 24VAC CONTROL STATION: . . . . . . NEMA 1 three button station. OPEN/CLOSE/STOP WIRING TYPE: . . . . . . . . . . . . . . . . . C2 (Factory Shipped) Momentary contact to OPEN & STOP, constant pressure to CLOSE, open override plus wiring for sensing device to reverse. See page 8 for optional control settings. LIMIT ADJUST: . . . . . . . . . . . . . . . . Linear driven, fully adjustable screw type cams. [. . . ] Inside this enclosure you will find the wiring diagram(s) for your unit. Refer to the diagram (glued on the inside of the cover) for all connections described below. If this diagram is missing, call the number on the back of this manual. DO NOT INSTALL ANY WIRING OR ATTEMPT TO RUN THIS OPERATOR WITHOUT CONSULTING THE WIRING DIAGRAM. NING WARNING DISCONNECT POWER AT THE FUSE BOX BEFORE PROCEEDING. OPERATOR MUST BE PROPERLY GROUNDED AND PERMANENTLY WIRED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES. NOTE: THE OPERATOR SHOULD BE ON A SEPARATE FUSED LINE OF ADEQUATE CAPACITY. ALL ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED INDIVIDUAL. POWER WIRING 1. Be sure that the power supply is of the correct voltage, phase, frequency, and amperage to supply the operator. Refer to the operator nameplate on the cover. Using the 1-1/16" dia conduit access knockout as shown below, bring supply lines to the operator and connect wires to the terminals indicated on the WIRING CONNECTIONS DIAGRAM. DO NOT TURN POWER ON UNTIL YOU HAVE FINISHED MAKING ALL POWER AND CONTROL WIRING CONNECTIONS AND HAVE COMPLETED THE LIMIT SWITCH ADJUSTMENT PROCEDURE. TION WARNING WARNING TO AVOID DAMAGE TO DOOR AND OPERATOR, MAKE ALL DOOR LOCKS INOPERATIVE. SECURE LOCK(S) IN "OPEN" POSITION. IF THE DOOR LOCK NEEDS TO REMAIN FUNCTIONAL, INSTALL AN INTERLOCK SWITCH. WARNING IMPORTANT: THIS UNIT MUST BE PROPERLY GROUNDED. A GROUND SCREW IS SUPPLIED IN THE ELECTRICAL BOX FOR CONNECTION OF THE POWER SUPPLY GROUND WIRE. FAILURE TO PROPERLY GROUND THIS UNIT COULD RESULT IN ELECTRIC SHOCK AND SERIOUS INJURY. CAUTION WARNING ON THREE PHASE MACHINES ONLY!Generally a three button station (OPEN/CLOSE/STOP) is provided. A two-position key switch or control station (OPEN/CLOSE) may be added or substituted when requested at the time of order. Mount the control station near the door. MOUNT WARNING NOTICE WARNING INSTALL THE CONTROL STATION WHERE THE DOOR IS VISIBLE, BUT AWAY FROM THE DOOR AND ITS HARDWARE. IF CONTROL STATION CANNOT BE INSTALLED WHERE DOOR IS VISIBLE, OR IF ANY DEVICE OTHER THAN THE CONTROL STATION IS USED TO ACTIVATE THE DOOR, A REVERSING EDGE MUST BE INSTALLED ON THE BOTTOM OF THE DOOR. FAILURE TO INSTALL A REVERSING EDGE UNDER THESE CIRCUMSTANCES MAY RESULT IN SERIOUS INJURY OR DEATH TO PERSONS TRAPPED BENEATH THE DOOR. IMPORTANT: Mount WARNING NOTICE beside or below the push button station. Standard Control Station OPEN Push Buttons WARNING CLOSE TO PREVENT ENTRAPMENT DO NOT START DOOR DOWNWARD UNLESS DOORWAY IS CLEAR STOP WARNING Notice 8 CONTROL WIRING (con't) Radio Controls On all models with type B2 control wiring, a terminal bracket marked R1 R2 R3 is located on the outside of the electrical enclosure. All standard radio control receivers (single channel residential type) may be mounted to this bracket. The operator will then open a fully closed door, close a fully open door, and reverse a closing door from the radio transmitter. [. . . ] BRAKE SOLENOID ( WHEN REQUIRED ) BL-BK STOP ** 3 PHASE POWER IN BR BR J P Y 2 3 BL-BK 575V. CONNECTION OVERLOAD (UP TO 3/4 HP) GY 1 SAFETY EDGE NOTES: 1) TO REVERSE MOTOR DIRECTION: INTERCHANGE ANY 2 OF THE 3 POWER WIRES AT L1, L2 & L3, OR EXCHANGE PURPLE & GRAY MOTOR LEADS AT CONTACTOR 1 & 3 (3PH UNITS ONLY). **- Transformer Primary Voltage same as Line Voltage. 15 ILLUSTRATED PARTS ­ ELECTRICAL BOX S7 S1 S6 S5 S2 S8 S4 S9 L1 L3 S3 L7 1 6 9 5 L8 L6 L2 8 L2 L5 L4 3 7 10 2 4 16 REPAIR PARTS KITS ­ ELECTRICAL BOX Below are replacement kits available for your operator. For replacement of electrical box, motor or brake components be sure to match model number of your unit to kit number below to ensure proper voltage requirements. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN GT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN GT will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag