User manual CHAMBERLAIN HCT 501130

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CHAMBERLAIN HCT 501130. We hope that this CHAMBERLAIN HCT 501130 user guide will be useful to you.

Lastmanuals help download the user guide CHAMBERLAIN HCT 501130.


Mode d'emploi CHAMBERLAIN HCT 501130
Download
Manual abstract: user guide CHAMBERLAIN HCT 501130

Detailed instructions for use are in the User's Guide.

[. . . ] TABLE OF CONTENTS Features and Specifications Role of Specifiers and Designers Role of Dealers, Installers and Trained System Technicians UL Gate Classifications Role of End Users Overhead Gate / Door Systems Safety Installation Instructions Steps 1-2 Installation of Operator Steps 3-5 Mounting the Operator Step 6 How to Connect Power (120 Vac) Earth Ground Rod Step 7 Mounting and Wiring of the Reset Switch Step 8 Adjusting the Traveling Distance (Limit Switches) Step 9 Two Way Adjustable Reversing Sensor Step 10 Adjustable Timer Step 11 Terminal Input Connections Steps 12-13 IMPORTANT INFORMATION Operating Instructions for Optional Systems Three Push Button System House Alarm / Proximity Switch Connections Optional Relay Adapter Connection Secondary Entrapment Protection (Contact Sensor) Secondary Entrapment Protection (Non-Contact Sensor) Optional Plug-In Loop Detectors Wiring External Loop Detectors Programming the Radio Receiver Replacing the Control Board Audio Alarm Important Safety Instructions MANUAL RELEASE Troubleshooting Table Troubleshooting / LED Information Parts Illustrations Parts List Maintenance Accessories Operator Notes 2 3 3 4 5 5 6 7 8 9 10 11 12 12 13 14 15 15 16 17 18 19 20 21 22-23 24 24 25 26 27 28 29 30 30 31 32 MAINTENANCE & OPERATION INSTA LLA TIO N Important: DO NOT attempt repair or service of your commercial door and gate operator unless you are an Authorized Service Technician. For Toll Free Technical Support: 1-800-528-2806 www. liftmaster. com 1 FEATURES AND SPECIFICATIONS 141" 8. 25" 22. 01" VARIABLE OPERATING LENGTHS Door Height Operator Length 8 ft. Door 189 in. 4" 18. 875" 8. 36" CONTINUOUS CYCLE 240 LBS. PULL COMMERCIAL DOOR AND GATE OPERATOR 1/2 HP ­ 120 VAC 1PH ­ 60HZ ­ 4. 8 AMPS WEIGHT 123 LBS MOTOR - 120VAC 4. 8 Amp 1/2 HP instant reversing parking gate Leeson Motor GEAR BOX - 40 to 1 ratio, lubrication by oil bath gives smooth, quiet operation and features positive gate locking. NOISE ISOLATOR - Heavy duty rubber attachments isolate vibration, absorb shock and eliminate noise. [. . . ] Plug the interface cable (Figure 2) into the J5 receptacle on the Omni control board (Figure 3). Connect like wires from the reset switch to the interface cable. NOTE: The wire connecting the interface cable to the reset switch is not provided. WARNING To prevent possible SERIOUS INJURY or DEATH from electrocution, disconnect electric power to operator BEFORE installing. ALL electrical connections MUST be made by a qualified individual. Figure 1 RESET 6' min. RESET Figure 2 CENTER SAFETY EXIT Figure 3 DC-BACKUP QCC SENSOR ALARM Plug Reset Switch Connector to J5 Connector J5 DC-BACKUP W4 GBA OPEN A B MAGLOCK ALARM ARMED M / S L I NK MS STOP LINK CLOSE SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN CLOSE STOP REVERSE SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT MADE IN USA 1 3 1 3 EXIT COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR 10 ADJUSTING TRAVELING DISTANCE STEP 8 Before Adjusting, Do the Following: 1. If further adjustment is needed, repeat the process. Push Plate 11 2-WAY ADJUSTABLE REVERSING SENSOR STEP 9 Adjusted by Qualified Service Personnel CENTER SAFETY EXIT 3 1 3 DC-BACKUP W4 GBA MS LINK SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN REVERSE SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT SENSOR ALARM REVERSE SENSOR Maximum Sensitivity MADE IN USA 1 3 1 3 COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR DO NOT TOUCH ALARM SENSOR The level of reverse sensitivity has to do with the weight of the gate/door and the condition of installation. Too sensitive = If the gate/door stops or reverses by itself. Not sensitive enough = If the gate/door hits an obstruction or vehicle and does not stop or reverse. ADJUSTABLE TIMER STEP 10 TIMER CENTER SAFETY EXIT CLOSE Minimum Sensitivity EXIT STOP Timer ON 60 3 Set Timer Decrease Time NSOR OFF OPEN LEFT ON 1 3 OPEN RIGHT DC-BACKUP SENSOR ALARM W4 GBA MS LINK Increase Time TIMER NSOR SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN REVERSE SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT MADE IN USA 1 3 1 3 60 3 EXIT COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED CLOSE STOP EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR OFF OPEN LEFT 1 3 ON OPEN RIGHT Timer can be set from 1 to 60 seconds (Timer ON), For push open/push close type operation (Timer OFF). Timer OFF 12 DC-BACKUP TERMINAL INPUT CONNECTIONS GBA MS LINK W4 SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN REVERSE SENSOR Important: Terminals 11 and 12 are the only terminals that will both Open and/or Close with OFF ON a single push of a button. All other terminals will only open with a single push of a button. ALARM SENSOR 1 3 1 3 1 3 OPEN LEFT OPEN RIGHT COMMAND PROCESSED CENTER SAFETY EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR Ground (-) 24 Vdc (+) ® OmniControl Surge Suppressor P/N Q410 Patent Pending 123456 7 8 9 10 11 12 13 Removable Terminal Connectors ­ + Radio Receiver G B M/S Link A Center Loop Safety Loop Exit Loop Fire Dept. Key Switch Strike Open Push Button Class 2 Supply 24 Volts DC CLOSE STEP 11 FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED Output Power STOP EXIT SENSOR ALARM MADE IN USA 3 Wire 24 Vdc Radio Receiver Master/Second Link: Not used in normal installation 13 + Radio Power Relay 12 11 ­ 24 Volt Wire 4 Wire 24 Vdc Radio Receiver WARNING: To ENSURE proper operation of safety devices: · ENSURE bare wire makes good contact inside removable terminal connectors. · DO NOT let wire insulation interfere with connection. 13 + Red 24 Volt Grey 12 11 ­ Black 11 ­ Grey 3 4 10 Card Reader External "Safety" Loop Detector 9 ® ® 11 Ground (-) 13 24VDC (+) ® 10 9 Push Button +24V SENSING EDGE INPUT INFRARED BLACK or BROWN COMMON INFRARED WHITE or BLUE 3 4 Photo Electric Sensors (Safety) 5 6 10 9 Phone Entry 1 4 7 HELP 2 5 8 0 3 6 9 External "Exit" Loop Detector 8 7 Fire or Any Key Switch 13 IMPORTANT INFORMATION STEP 12 MER 60 CENTER SAFETY EXIT 1 3 OFF ON OPEN RIGHT OPEN LEFT DC-BACKUP SENSOR ALARM W4 GBA MS LINK SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN RADIO REVERSE SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT MADE IN USA 1 3 1 3 EXIT COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE STOP Make sure the system is "OPEN TO LEFT" STEP 13 Installers are required to adhere to this procedure: The UL required Warning Signs must be installed in plain view and on both sides of each commercial gate installed. Each sign is made with fastening holes in each corner and should be permanently secured in a suitable manner. 14 INSTRUCTIONS FOR OPTIONAL SYSTEMS CENTER SAFETY EXIT QCC AB OPEN SENSOR ALARM STOP CLOSE MAGLOCK ALARM ARMED M / S LIN K DC-BACKUP QCC W4 GBA OPEN A B MAGLOCK ALARM ARMED M/S LINK MS LINK STOP CLOSE SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN STOP REVERSE SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT MADE IN USA 1 3 1 3 EXIT COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED CLOSE 1 N. O. 2 Gnd 3 N. C. 4 Gnd 5 N. O. 6 Gnd 7 Com 8 N. C. 9 10 11 12 13 14 15 16 N. O. Gnd Gnd B POWER OVERLOAD OPEN CLOSE STOP SENSOR ALARM MADE IN USA QCC is designed for slide gate operators only! 1 3 5 & & & 2 4 6 7 8 9 ­ ­ ­ ­ ­ ­ Open Command Stop Command 10 & 11 Close Command 12 & 13 Common 14 Relay Contact Rating Normally Closed 0. 5 Amp - 125 Vac 15 1 Amp - 24 Vdc Normally Open 16 Omni Option Board see Accessories page ­ ­ ­ ­ ­ Burglar Alarm Output Burglar Alarm Input Ground Master/Second B RS485 A 3-BUTTON STATION Omni "Option Board" Needed to Perform This Function WARNING: For proper operation, cut OPEN STOP CLOSE W4 BEFORE installing option board. CENTER SAFETY EXIT 1 N. O. N. C. 2 3 4 5 6 DC-BACKUP QCC W4 GBA OPEN A B MAGLOCK ALARM ARMED M/S LINK MS LINK STOP CLOSE N. O. Com EXIT SENSORS SYSTEM ON TIMER 60 3 REVERSE SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT 1 3 1 3 COMMAND PROCESSED 3-Button Station (OPEN-STOP-CLOSE) Step 1 - Disconnect power. Step 2 - Cut jumper wire #W4. Note: If this jumper is not cut, the stop button will not function. CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR W4 Note: If using the Master/Second board configuration, unplug the Master/Second link plug on main board and connect it into the Omni option board M/S link socket. Make sure each push button is dry contact and there are no jumper wires between them. Step 3 Step 4 Step 5 Step 6 Step 7 - Install Omni option board. Connect COMMON to # 6 . 15 A EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR ALARM/PROXIMITY SWITCH CONNECTIONS Omni "Option Board" needed to perform this function. See Accessories page. Alarm QCC 10 ­ Common 11 ­ Normally Open A OPEN STOP CLOSE B MAGLOCK ALARM ARMED M/ S LINK Armed 12 ­ Normally Closed 13 ­ Ground 10 11 12 13 Omni Option Board Proximity Switch see Accessories page CENTER SAFETY EXIT DC-BACKUP QCC W4 OPEN A B MAGLOCK ALARM ARMED M/S LINK GSTOP CLOSE BA MS LINK SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN CLOSE STOP REVERSE SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT 1 3 1 3 EXIT COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR SENSOR ALARM MADE IN USA Use Low Voltage Wire 20 AWG 12Vdc Alarm System Dry Contact 2" Max. 2" Max. 16 OPTIONAL RELAY ADAPTER CONNECTION See Accessories page for Relay Adapter Module CENTER SAFETY EXIT DC-BACKUP SENSOR ALARM W4 GBA MS LINK SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN Connection of a Solenoid or Magnetic Lock can be made using the "Optional" Relay Adapter Module. REVERSE SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT MADE IN USA 1 3 1 3 EXIT STOP Relay Contact Rating 2 Amp - 125 AC/DC 2 Amp switching load capability COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE Solenoid Lock Solenoid Lock Ground To OmniControl Board Common Normally Closed Optional Relay Adapter Module Plug-In Transformer Relay Module LEDs Power Relay Light On: Ground Indicates actuation of OmniControl board Magnetic Lock Plug-In Transformer Magnetic Lock Power Light On: Indicates power is being received To OmniControl Board Ground Common Power Ground Normally Open Optional Relay Adapter Module 17 SECONDARY ENTRAPMENT PROTECTION Secondary Entrapment Protection (Contact Sensor) When touched, the electrically activated edge sensors immediately signal the door/gate operator to stop and reverse. Property owners are obligated to test edges regularly. Edge Sensor Wiring ® OmniControl Surge Suppressor P/N Q410 Patent Pending 123456 7 8 9 10 11 12 13 ­ + Radio Receiver G B M/S Link A Center Loop Safety Loop Exit Loop Fire Dept Key Switch Strike Open Push Button Class 2 Supply 24 Volts DC UL Listed Edge Sensor (3-Sided Activation) Note: If multiple sensors are being used, all of the edge sensors are to be connected in parallel at the sensor input on the OmniControl board. UL Listed Edge Sensor (3-Sided Activation) If you are going to use a contact sensor as a secondary entrapment protection, you should use a recognized component to comply with the revised UL325 intended to be used in class I or class II gate operator. 18 SECONDARY ENTRAPMENT PROTECTION Secondary Entrapment Protection (Non-Contact Sensor) Mount Photo Beam Sensor at Recommended Height and Align Properly If an obstruction breaks the light beam while the door is closing, the door will stop and reverse to full open position. Patent Pending OmniControl Surge S ­ Strike Open Push Button + Radio Receiver Center Loop Safety Loop Exit Loop F Ke ® OmniControl Surge Suppressor P/N Q410 Patent Pending (LiftMaster Commercial Protector System shown) 3 4 ­ + Radio Receiver Class 2 Supply 24 Volts DC G B M/S Link A Center Loop Safety Loop Exit Loop Fire Dept Key Switch Strike Open Push Button 13 +24V 11 COMMON SENSING EDGE INFRARED INPUT BLACK or BROWN INFRARED WHITE or BLUE ® Emitter Receiver If you are going to use a non-contact sensor as a secondary entrapment protection, you should use a recognized component to comply with the revised UL325 intended to be used in class I or class II gate operator. See Accessories page for acceptable non-contact safety devices. 19 OPTIONAL PLUG-IN LOOP DETECTORS CAUTION: Use different frequencies for every single loop detector. Turn off operator power (breaker switch from main power source) before installation. Refer. Bus 1, 2, 3 On Off CENTER SAFETY EXIT Air (1) Conditioner On Off Conference Rm 2, 3 Main Room SENSOR ALARM Conference Room 2 Off Off Conference Room 1 On Off Off Off On Gate Operator Eug. [. . . ] This is a normal response of the gate/door operator. It does not represent necessarily that there is a problem. This is a normal response of the gate/door operator. It does not represent necessarily that there is a problem. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN HCT 501130

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN HCT 501130 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag