If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CHAMBERLAIN HCT 501130. We hope that this CHAMBERLAIN HCT 501130 user guide will be useful to you.
Lastmanuals help download the user guide CHAMBERLAIN HCT 501130.
Manual abstract: user guide CHAMBERLAIN HCT 501130
Detailed instructions for use are in the User's Guide.
[. . . ] TABLE OF CONTENTS
Features and Specifications Role of Specifiers and Designers Role of Dealers, Installers and Trained System Technicians UL Gate Classifications Role of End Users Overhead Gate / Door Systems Safety Installation Instructions Steps 1-2 Installation of Operator Steps 3-5 Mounting the Operator Step 6 How to Connect Power (120 Vac) Earth Ground Rod Step 7 Mounting and Wiring of the Reset Switch Step 8 Adjusting the Traveling Distance (Limit Switches) Step 9 Two Way Adjustable Reversing Sensor Step 10 Adjustable Timer Step 11 Terminal Input Connections Steps 12-13 IMPORTANT INFORMATION Operating Instructions for Optional Systems Three Push Button System House Alarm / Proximity Switch Connections Optional Relay Adapter Connection Secondary Entrapment Protection (Contact Sensor) Secondary Entrapment Protection (Non-Contact Sensor) Optional Plug-In Loop Detectors Wiring External Loop Detectors Programming the Radio Receiver Replacing the Control Board Audio Alarm Important Safety Instructions MANUAL RELEASE Troubleshooting Table Troubleshooting / LED Information Parts Illustrations Parts List Maintenance Accessories Operator Notes 2 3 3 4 5 5 6 7 8 9 10 11 12 12 13 14 15 15 16 17 18 19 20 21 22-23 24 24 25 26 27 28 29 30 30 31 32
MAINTENANCE & OPERATION
INSTA LLA TIO N
Important: DO NOT attempt repair or service of your commercial door and gate operator unless you are an Authorized Service Technician.
For Toll Free Technical Support: 1-800-528-2806 www. liftmaster. com
1
FEATURES AND SPECIFICATIONS
141" 8. 25" 22. 01"
VARIABLE OPERATING LENGTHS Door Height Operator Length 8 ft. Door 189 in.
4" 18. 875"
8. 36"
CONTINUOUS CYCLE 240 LBS. PULL COMMERCIAL DOOR AND GATE OPERATOR
1/2 HP 120 VAC 1PH 60HZ 4. 8 AMPS WEIGHT 123 LBS
MOTOR - 120VAC 4. 8 Amp 1/2 HP instant reversing parking gate Leeson Motor GEAR BOX - 40 to 1 ratio, lubrication by oil bath gives smooth, quiet operation and features positive gate locking. NOISE ISOLATOR - Heavy duty rubber attachments isolate vibration, absorb shock and eliminate noise. [. . . ] Plug the interface cable (Figure 2) into the J5 receptacle on the Omni control board (Figure 3). Connect like wires from the reset switch to the interface cable. NOTE: The wire connecting the interface cable to the reset switch is not provided.
WARNING
To prevent possible SERIOUS INJURY or DEATH from electrocution, disconnect electric power to operator BEFORE installing. ALL electrical connections MUST be made by a qualified individual.
Figure 1
RESET
6' min.
RESET
Figure 2
CENTER
SAFETY
EXIT
Figure 3
DC-BACKUP
QCC
SENSOR ALARM
Plug Reset Switch Connector to J5 Connector
J5
DC-BACKUP
W4 GBA
OPEN A B MAGLOCK ALARM ARMED M / S L I NK
MS STOP LINK CLOSE
SENSORS
SYSTEM ON
TIMER 60 3
POWER OVERLOAD OPEN CLOSE STOP
REVERSE SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
MADE IN USA
1
3
1
3
EXIT
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
10
ADJUSTING TRAVELING DISTANCE
STEP 8
Before Adjusting, Do the Following:
1. If further adjustment is needed, repeat the process.
Push Plate
11
2-WAY ADJUSTABLE REVERSING SENSOR
STEP 9
Adjusted by Qualified Service Personnel
CENTER
SAFETY
EXIT
3
1
3
DC-BACKUP
W4 GBA
MS LINK
SENSORS
SYSTEM ON
TIMER 60 3
POWER OVERLOAD OPEN
REVERSE SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
SENSOR ALARM
REVERSE SENSOR
Maximum Sensitivity
MADE IN USA
1
3
1
3
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
DO NOT TOUCH ALARM SENSOR
The level of reverse sensitivity has to do with the weight of the gate/door and the condition of installation. Too sensitive = If the gate/door stops or reverses by itself. Not sensitive enough = If the gate/door hits an obstruction or vehicle and does not stop or reverse.
ADJUSTABLE TIMER
STEP 10
TIMER
CENTER SAFETY EXIT
CLOSE
Minimum Sensitivity
EXIT
STOP
Timer ON
60 3
Set Timer Decrease Time
NSOR
OFF
OPEN LEFT
ON
1
3
OPEN RIGHT
DC-BACKUP
SENSOR ALARM
W4 GBA
MS LINK
Increase Time TIMER
NSOR
SENSORS
SYSTEM ON
TIMER 60 3
POWER OVERLOAD OPEN
REVERSE SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
MADE IN USA
1
3
1
3
60
3
EXIT
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
CLOSE
STOP
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
OFF
OPEN LEFT
1
3
ON
OPEN RIGHT
Timer can be set from 1 to 60 seconds (Timer ON), For push open/push close type operation (Timer OFF).
Timer OFF
12
DC-BACKUP
TERMINAL INPUT CONNECTIONS
GBA
MS LINK
W4
SENSORS
SYSTEM ON
TIMER
60
3
POWER OVERLOAD
OPEN
REVERSE SENSOR
Important: Terminals 11 and 12 are the only terminals that will both Open and/or Close with OFF ON a single push of a button. All other terminals will only open with a single push of a button.
ALARM SENSOR
1 3
1
3
1
3
OPEN LEFT
OPEN RIGHT
COMMAND PROCESSED
CENTER SAFETY
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
Ground (-) 24 Vdc (+)
®
OmniControl Surge Suppressor
P/N Q410 Patent Pending
123456
7 8 9 10 11 12 13
Removable Terminal Connectors
+ Radio Receiver
G
B
M/S Link
A
Center Loop
Safety Loop
Exit Loop
Fire Dept. Key Switch
Strike Open Push Button
Class 2 Supply
24 Volts DC
CLOSE
STEP 11
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
Output Power
STOP
EXIT
SENSOR ALARM
MADE IN USA
3 Wire 24 Vdc Radio Receiver
Master/Second Link: Not used in normal installation
13 + Radio Power Relay 12 11 24 Volt
Wire
4 Wire 24 Vdc Radio Receiver
WARNING: To ENSURE proper operation
of safety devices: · ENSURE bare wire makes good contact inside removable terminal connectors. · DO NOT let wire insulation interfere with connection.
13 + Red 24 Volt Grey 12 11 Black 11 Grey
3 4
10
Card Reader
External "Safety" Loop Detector
9
®
®
11 Ground (-) 13 24VDC (+)
®
10 9
Push Button
+24V SENSING EDGE INPUT INFRARED BLACK or BROWN COMMON INFRARED WHITE or BLUE
3 4
Photo Electric Sensors (Safety)
5 6
10 9
Phone Entry
1 4 7
HELP
2 5 8 0
3 6 9
External "Exit" Loop Detector
8 7
Fire or Any Key Switch
13
IMPORTANT INFORMATION
STEP 12
MER 60
CENTER SAFETY EXIT
1
3
OFF
ON
OPEN RIGHT
OPEN LEFT
DC-BACKUP SENSOR ALARM
W4 GBA
MS LINK
SENSORS
SYSTEM ON
TIMER 60 3
POWER OVERLOAD OPEN
RADIO
REVERSE SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
MADE IN USA
1
3
1
3
EXIT
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
CLOSE
STOP
Make sure the system is "OPEN TO LEFT"
STEP 13
Installers are required to adhere to this procedure: The UL required Warning Signs must be installed in plain view and on both sides of each commercial gate installed. Each sign is made with fastening holes in each corner and should be permanently secured in a suitable manner.
14
INSTRUCTIONS FOR OPTIONAL SYSTEMS
CENTER
SAFETY
EXIT
QCC
AB
OPEN
SENSOR ALARM
STOP
CLOSE
MAGLOCK
ALARM
ARMED
M / S LIN K
DC-BACKUP
QCC
W4 GBA
OPEN A B MAGLOCK ALARM ARMED M/S LINK
MS LINK STOP CLOSE
SENSORS
SYSTEM ON
TIMER 60 3
POWER OVERLOAD OPEN STOP
REVERSE SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
MADE IN USA
1
3
1
3
EXIT
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
CLOSE
1
N. O.
2
Gnd
3
N. C.
4
Gnd
5
N. O.
6
Gnd
7
Com
8
N. C.
9 10 11 12 13 14 15 16
N. O. Gnd Gnd B
POWER OVERLOAD OPEN CLOSE STOP
SENSOR ALARM
MADE IN USA
QCC is designed for slide gate operators only!
1 3 5
& & &
2 4 6 7 8 9
Open Command Stop Command 10 & 11 Close Command 12 & 13 Common 14 Relay Contact Rating Normally Closed 0. 5 Amp - 125 Vac 15 1 Amp - 24 Vdc Normally Open 16
Omni Option Board see Accessories page
Burglar Alarm Output Burglar Alarm Input Ground Master/Second B RS485 A
3-BUTTON STATION
Omni "Option Board" Needed to Perform This Function
WARNING: For proper operation, cut
OPEN STOP CLOSE
W4 BEFORE installing option board.
CENTER SAFETY EXIT
1 N. O. N. C.
2
3
4
5
6
DC-BACKUP
QCC
W4 GBA
OPEN A B MAGLOCK ALARM ARMED M/S LINK
MS LINK STOP CLOSE
N. O.
Com
EXIT
SENSORS
SYSTEM ON
TIMER 60 3
REVERSE SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
1
3
1
3
COMMAND PROCESSED
3-Button Station (OPEN-STOP-CLOSE) Step 1 - Disconnect power. Step 2 - Cut jumper wire #W4.
Note: If this jumper is not cut, the stop button will not function.
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
W4
Note: If using the Master/Second board configuration, unplug the Master/Second link plug on main board and connect it into the Omni option board M/S link socket. Make sure each push button is dry contact and there are no jumper wires between them.
Step 3 Step 4 Step 5 Step 6 Step 7 -
Install Omni option board. Connect COMMON to # 6 .
15
A
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
ALARM/PROXIMITY SWITCH CONNECTIONS
Omni "Option Board" needed to perform this function. See Accessories page.
Alarm
QCC
10 Common 11 Normally Open
A OPEN STOP CLOSE
B MAGLOCK ALARM ARMED M/ S LINK
Armed
12 Normally Closed 13 Ground
10
11
12
13
Omni Option Board Proximity Switch see Accessories page
CENTER
SAFETY
EXIT
DC-BACKUP
QCC
W4
OPEN
A
B MAGLOCK ALARM ARMED M/S LINK
GSTOP CLOSE BA
MS LINK
SENSORS
SYSTEM ON
TIMER 60 3
POWER OVERLOAD OPEN CLOSE STOP
REVERSE SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
1
3
1
3
EXIT
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
SENSOR ALARM
MADE IN USA
Use Low Voltage Wire 20 AWG 12Vdc Alarm System Dry Contact
2"
Max.
2"
Max.
16
OPTIONAL RELAY ADAPTER CONNECTION
See Accessories page for Relay Adapter Module
CENTER
SAFETY
EXIT
DC-BACKUP
SENSOR ALARM
W4 GBA
MS LINK
SENSORS
SYSTEM ON
TIMER 60 3
POWER OVERLOAD OPEN
Connection of a Solenoid or Magnetic Lock can be made using the "Optional" Relay Adapter Module.
REVERSE SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
MADE IN USA
1
3
1
3
EXIT
STOP
Relay Contact Rating
2 Amp - 125 AC/DC 2 Amp switching load capability
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
CLOSE
Solenoid Lock
Solenoid Lock
Ground
To OmniControl Board
Common Normally Closed Optional Relay Adapter Module
Plug-In Transformer
Relay Module LEDs
Power
Relay Light On:
Ground
Indicates actuation of OmniControl board
Magnetic Lock Plug-In Transformer
Magnetic Lock
Power Light On: Indicates power is being received
To OmniControl Board
Ground
Common
Power Ground
Normally Open Optional Relay Adapter Module
17
SECONDARY ENTRAPMENT PROTECTION
Secondary Entrapment Protection (Contact Sensor)
When touched, the electrically activated edge sensors immediately signal the door/gate operator to stop and reverse. Property owners are obligated to test edges regularly. Edge Sensor Wiring
®
OmniControl Surge Suppressor
P/N Q410 Patent Pending
123456
7 8 9 10 11 12 13
+ Radio Receiver
G
B
M/S Link
A
Center Loop
Safety Loop
Exit Loop
Fire Dept Key Switch
Strike Open Push Button
Class 2 Supply
24 Volts DC
UL Listed Edge Sensor (3-Sided Activation)
Note: If multiple sensors are being used, all of the edge sensors are to be connected in parallel at the sensor input on the OmniControl board.
UL Listed Edge Sensor (3-Sided Activation)
If you are going to use a contact sensor as a secondary entrapment protection, you should use a recognized component to comply with the revised UL325 intended to be used in class I or class II gate operator.
18
SECONDARY ENTRAPMENT PROTECTION
Secondary Entrapment Protection (Non-Contact Sensor)
Mount Photo Beam Sensor at Recommended Height and Align Properly
If an obstruction breaks the light beam while the door is closing, the door will stop and reverse to full open position.
Patent Pending
OmniControl Surge S
Strike Open Push Button
+ Radio Receiver
Center Loop
Safety Loop
Exit Loop
F Ke
®
OmniControl Surge Suppressor
P/N Q410 Patent Pending
(LiftMaster Commercial Protector System shown)
3 4
+ Radio Receiver
Class 2 Supply
24 Volts DC
G
B
M/S Link
A
Center Loop
Safety Loop
Exit Loop
Fire Dept Key Switch
Strike Open Push Button
13
+24V
11
COMMON SENSING EDGE INFRARED INPUT BLACK or BROWN INFRARED WHITE or BLUE
®
Emitter
Receiver
If you are going to use a non-contact sensor as a secondary entrapment protection, you should use a recognized component to comply with the revised UL325 intended to be used in class I or class II gate operator. See Accessories page for acceptable non-contact safety devices.
19
OPTIONAL PLUG-IN LOOP DETECTORS
CAUTION: Use different frequencies for
every single loop detector. Turn off operator power (breaker switch from main power source) before installation.
Refer. Bus 1, 2, 3
On
Off
CENTER
SAFETY
EXIT
Air (1) Conditioner
On
Off
Conference Rm 2, 3
Main Room
SENSOR ALARM
Conference Room 2
Off
Off
Conference Room 1
On
Off
Off
Off
On
Gate Operator
Eug. [. . . ] This is a normal response of the gate/door operator. It does not represent necessarily that there is a problem. This is a normal response of the gate/door operator. It does not represent necessarily that there is a problem. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN HCT 501130
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN HCT 501130 will begin.