Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CHAMBERLAIN LA400. We hope that this CHAMBERLAIN LA400 user guide will be useful to you.
Lastmanuals help download the user guide CHAMBERLAIN LA400.
You may also download the following manuals related to this product:
CHAMBERLAIN LA400 ADDENDUM (214 ko)
Manual abstract: user guide CHAMBERLAIN LA400
Detailed instructions for use are in the User's Guide.
[. . . ] INSTALLATION/OPERATION MANUAL
MODEL LA400
MEDIUM DUTY SWING GATE OPERATOR
Radio Receiver Built on Board
315MHz
2 YEAR WARRANTY
Serial # Primary Arm Serial # Secondary Arm Serial # Control Box Installation Date
TABLE OF CONTENTS
Introduction 2-5
Carton Inventory . . 3 Additional Items Needed for Installation . . 3 Operator Dimensions and Specifications . . 32 Safety Accessories for Secondary Entrapment Protection . [. . . ] NOTE: Used for Dual Gate installations only.
TIMER TO CLOSE ENABLE Set the TIMER TO CLOSE to desired setting. The range is 0 to 180 seconds, 0 seconds is OFF.
FORCE
BI-PART DELAY
TIMER TO CLOSE
Minimun Force
Maximum Force
OFF
MAX
OFF
MAX
Your basic installation is now complete. 26
OPTIONAL CONTROL AND SAFETY DEVICES
To Add or Reprogram a Remote Control
1. Press and release "LEARN XMITTER" button (LED will light up). Press and hold remote button, the LED will flash, alarm will beep twice and the LED will go out. Repeat steps 1 and 2 until all remote controls are programmed (50 remote controls maximum). NOTE: For highest level of security, we recommend the 315 MHz, Security® line of products. Refer to Accessories.
R1
LEARN XMITTER
Remote Control "LEARN XMITTER" Button
P2
CLOSE EDGE
J19 Ø14GP 89ØE 14GPØ89 Ø14LG 89ØE 14LGØ89 Ø14SK 89ØE 14SKØ89 J1
OPEN/EGE PHOTO
L1
1
O N
S8
LEARN XMITTER
2
OFF OFF SINGLE NO NO
ON SAVE ON MAGLOCK DUAL MODE NC EDGE NC PHOTO
12345 S1
OPEN PHOTO
CLOSE PHOTO
24V
OVLD
SWITCHED ACCESSORY POWER
To Erase All Codes To deactivate any unwanted remote controls, first erase all codes: Press and hold the "LEARN XMITTER" button on logic board until the learn indicator light goes out (approximately 6 seconds). Reprogram each remote control or keyless entry you wish to use.
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS. Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
27
Dip Switch Settings
SAVE SWITCH S1-1 This switch (S1-1) is used to save the settings for switches 2 through 5. NOTE: When setting switches, the save switch must be in the off position prior to setting or changing switches for the change to be saved. MAG DELAY ENABLE This switch (S1-2) enables the Maglock feature. On an open command there will be a . 5 second delay before the motor starts, to allow the Maglock to release. MODE DUAL/SINGLE This switch (S1-3) sets the mode as Dual or Single (Refer to page 24). SAFETY INPUTS Swing gates allow four safety inputs. A DIP switch is required for determining between N/O and N/C edges and N/O and N/C eyes. EDGE INPUT Set switch (S1-4) to the following settings: N/O Edge (Active Close) = N/O dry contact edge or monitored edge NOTE: Monitored Edges should be set in the N/O position, as the activation condition is shorting the terminals. EYE INPUT This switch (S1-5) differentiates between N/O and N/C dry contact photoelectric eye inputs. NOTE: Pulsing Chamberlain (CPS-L) photoelectric eyes will automatically learn in N/O mode (See Accessories).
O N
O N
SAVE OFF
SAVE ON
12345
12345
O N
OFF OFF SINGLE NO NO
ON ON DUAL NC NC
SAVE MAGLOCK MODE EDGE PHOTO
O N
O N
12345
OFF MAG DELAY ON
ON MAG DELAY OFF
12345
12345
S1
FACTORY DEFAULT SHOWN
O N O N
P2
J19
Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE
J1
CLOSE EDGE
OPEN/EGE PHOTO
L1
1
S8
LEARN XMITTER
2
OFF OFF SINGLE NO NO
S1
ON SAVE ON MAGLOCK DUAL MODE NC EDGE NC PHOTO
OPEN PHOTO
CLOSE PHOTO
GATE1
OFF OFF SINGLE NO NO
ON ON DUAL NC NC
12345
12345
O N
12345
SET OPEN LIMIT
SET CLOSE LIMIT
LEARN LIMITS
24V
GATE 2
OVLD
SWITCHED ACCESSORY POWER
O N
OFF OFF SINGLE EDGE NO
ON ON DUAL NC
12345
O N
OFF OFF SINGLE EYE NO
28
ON ON DUAL NC
12345
Wire Stop Button (Optional)
A jumper wire is factory installed between the stop and common input. Stop (N/C) - Stop only (does not reset alarm). [. . . ] Includes mounting hardware and electrical interface box. Commercial Protector System® (Direct Connect): Maximum range is 45' 24V. Includes mounting hardware.
CPS-LN4
43
WARRANTY POLICY AND SERVICE
LIFTMASTER® TWO YEAR LIMITED WARRANTY
The Chamberlain Group, Inc. warrants to the first purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of two years from the date of purchase. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN LA400
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN LA400 will begin.