[. . . ] ** Restricted close mode requires a constant pressure close command. The operator will begin closing after a 5 second delay and will continue to close to the close limit switch. The operator will stop if the pressure to close is released before reaching the close limit.
WARNING CAUTION
To prevent possible SEVERE INJURY or DEATH, install reversing sensors when: · The radio is used. · The 3-button control station is out of sight of the door. [. . . ] Press and release the LEARN button (LED will light). Every press and release of the STOP button will add 5 seconds to the Timer to Close. Example: 30 second TTC = 6 presses of the STOP button. Press and release the TTC button to exit programming mode. The LED will flash once per 5 seconds of timer setting. The TTC will become active after completion of the next open cycle.
NOTE: The LED does not indicate that timer is running.
1 2 3 4 5
OPEN
LEARN
D14 LED
D7 U4 D6 D5 D4
STOP
CLOSE OPEN
014A1030
TP1 C9 C21 C20
J4 C32 R25 U1
C31
L5
AUX ANT AUX ANT
J2
^^^^ C18 R27 D14 K2 LT C29 R24 P1
TTC
LED
1 2
LEARN STOP CLOSE OPEN
3 4 5 6 7
6
7
D9
LMEP1
LMEP2
COM
INTRLK
STOP
CLOSE
OPEN
TO VERIFY TIMER TO CLOSE (TTC) SETTING 1. Press and release the TTC button a second time. The LED will flash once per 5 seconds of timer setting.
Electrical Box Logic Board Timer To Close Button
MEP1 LMEP2 COM INTRLK STOP CLOSE OPEN
3-BUTTON REMOTE CONTROL TO OPERATE AS A WIRELESS 3-BUTTON CONTROL STATION
NOTE: The feature will use 3 of the 20 memory channels in the operator.
TTC
D14 LED
D7 U4 D6 D5 D4
LEARN
STOP
CLO
TO PROGRAM Open 1. Press and hold the LEARN button Close Stop (LED will light). Press the desired button on the logic board (OPEN, CLOSE or STOP). Press and hold the desired button of the remote control until LED flashes rapidly, then release. Repeat steps 1 through 3 to program additional buttons. TO ERASE ALL REMOTE CONTROLS Press and hold the LEARN button (over 5 seconds) until the LED goes out. All programmed remote controls will be erased.
Electrical Box Logic Board
014A1030
TP1 C9 C21 C20
J4 C32 R25 U1
C31
L5
AUX ANT AUX ANT
J2
^^^^ C18 R27 D14 K2 LT C29 R24 P1
1
LEARN STOP CLOSE OPEN
3 4 5 6 7 COM INTRLK STOP CLOSE OPEN
2
3
4
5
TTC
LED
1 2
D9
LMEP1
LMEP2
LMEP1 LMEP2 COM INTRLK STOP CL
CLEAR THE TIMER TO CLOSE (TTC) 1. Press and release the LEARN button (LED will light. ) 2. Press and hold the TTC button for 6 seconds. Release the TTC button (LED will go out). TIMER DEFEAT The TTC can be temporarily disabled by pressing a STOP button. TTC will become enabled after the next open command.
RADIO OPERATION
MODE OPEN CLOSE STOP REVERSE WHILE CLOSING TTC RESET
LEARN
D14 LED
D7 U4 D6 D5 D4
STOP
CLOSE OPEN
014A1030
TP1 C9 C21 C20
J4 C32 R25 U1
C31
L5
AUX ANT AUX ANT
J2
^^^^ C18 R27 D14 K2 LT C29 R24 P1
TTC
LED
1 2
LEARN STOP CLOSE OPEN
3 4 5 6 7
1
2
3
4
5
6
7
D9
LMEP1
LMEP2
COM
INTRLK
STOP
CLOSE
OPEN
MEP1 LMEP2 COM INTRLK STOP CLOSE OPEN
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS. Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
B2 B2 with TTC C2
X X X
X X (3 button remote)
X X X
X X X X WHEN OPEN
4
WARNING MANUAL DISCONNECT (MODELS MT/BMT & MH)
The operators have provisions for manually operating the door in case of emergency or power failure. [. . . ] Call qualified service contractor for maintenance. To locate a dealer in your area visit us online at www. liftmaster. com. The operator should be serviced at the following intervals: · Every 3 months or 5, 000 cycles · Every 6 months or 10, 000 cycles · Every 12 months or 20, 000 cycles
WARNING
To avoid SERIOUS PERSONAL INJURY or DEATH from electrocution, disconnect ALL electric power BEFORE performing ANY maintenance.
CAUTION
AVERTISSEMENT
8
ATTENTION
O P E R AT O R N O T E S
9
O P E R AT O R N O T E S
10
O P E R AT O R N O T E S
11
OPEN
OPEN
ACCESSORIES
ENTRAPMENT PROTECTION DEVICES
REMOTE CONTROLS 315MHz 371LM
OPEN
1-Button SECURITY® Remote Control: Includes visor clip.
Monitored CPS-LN4
PRESS
Commercial Protector System®: Provides protection on doors up to 45' wide. NEMA-4 rated.
OPEN
R ING
TO
373LM
3-Button SECURITY® Remote Control: Includes visor clip. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN MJ5011E
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.