[. . . ] Attention: This product may only be installed from professional installers. Only qualified and trained electricians may connect, programme and service the controls. Qualified and trained electricians meet the following requirements: - have knowledge of the general and specific safety and accident prevention regulations, - have knowledge of the relevant electrical regulations, - are trained in the use and care of appropriate safety equipment, - are capable of recognising the dangers associated with electricity.
Model Number: Controller Max. Gate weight (kg) Motor Protection Switch Hold to run function Automatic function IR-Sensor Automatic close Flashing Light Safety edges Emergency Stop Radio External Light switching function Traffic light with Red-Light Technical Data Voltage Phases Frequency Capacitor Current (nominal) Power Torque (max. ) Gear Reduction Duty Cycle Rating Temperature Range Thermal Protection: IP-Rating Gate Speed Sprocket Weight
SLY2500 none 2500kg yes no no no no no no no no no no
SLY2500E2 CB400 2500kg yes yes yes yes yes* yes* yes* yes* external yes* yes* * requires optional ZM-SKS-B plug in card
230V 1 50Hz 2 x 16µF 3, 85A 0, 55 kW 120Nm 1:40 50% -25/+55°C 140°C IP55 10m/min 90mm / Module 4 41kg
INSTALLATION OF DRIVE The base for the drive can either be concreted or, if appropriate, made of steel. [. . . ] · Mount the limit switch bracket such that the roller of the first switch is situated approximately in the middle of the bracket. Repeat this process for the open position. The bracket must be mounted with screws immediately. INITIAL OPERATION Check gate functionality manually when the drive has been disengaged. Electrical operation is possible only if a controller (CB400) is connected. ELECTRICAL CONNECTION: See electrical wiring diagram with control board CB400 · Control board pre-installed · Limit switch pre-wired to NC contacts · Motor pre-wired to control board box · Control board box pre-installed
Always ensure that the mechanical and electrical safety requirements relevant to the given system are complied with. A sliding gate can also be secured by implementing on-site measures (fence, wall, etc. ).
MAINTENANCE WORK (monthly) The drive mechanics are generally maintenance-free. Check at regular intervals that the gate hardware and the drive are all firmly in place. · Disengage the drive and check gate functionality. Only an easy-running gate will work well with a drive. A drive is no substitute for a poorly functioning gate. · Inspect for oil leakage on gear box. · Inspect for damage to electrical wiring
Declaration of Conformity
Automatic Gate Opener Models. . . . . . . . . SLY2500 are in conformity to the applicable sections of Standards: EN55014 · EN61000-3 · EN60555, EN60335-1 · ETS300 683 · EN60335-1: 2002 · EN60335-2-103: 2003 · EN55014-1: 2000 + A1 + A2 · EN55014-2: 2001 · EN61000-3-2: 2000 · EN61000-3-3: 1995 + A1 · EN 301 489-3, V1. 3. 1 · EN13241-1 per the provisions & all amendments of the EU Directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2006/95/EC, 2004/108/EC, 1999/5/EG
Declaration of Incorporation
Automatic Gate Opener Models , when installed and maintained according to all the Manufacturer's instructions in combination with a Gate, which has also been installed and maintained according to all the Manufacturer's instructions, meets the provisions of EU Directive 89/392/EEC and all amendments. I, the undersigned, hereby declare that the equipment specified above and any accessory listed in the manual conforms to the above Directives and Standards. Harry Naumann Manager, Regulatory Affairs Chamberlain GmbH D-66793 Saarwellingen Germany October, 2008
CONTROL BOARD KIT CB400 for AC SLIDING GATE OPERATORS
-Installation Instructionswww. liftmaster. de Email: info@chamberlain. de
Chamberlain GmbH Alfred Nobel Strasse 4 D-66793 Saarwellingen Germany
This product may only be installed from professional installers. Only qualified and trained electricians may connect, programme and service the controls. Qualified and trained electricians meet the following requirements: - have knowledge of the general and specific safety and accident prevention regulations, - have knowledge of the relevant electrical regulations, - are trained in the use and care of appropriate safety equipment, - are capable of recognising the dangers associated with electricity.
Attention:
Scope of these instructions:
These instructions describe the installation and options for the product CB400 (control board AS210B): Some features require the optional ZM-SKS plug in logic board to work. This manual should only be used together with SLY2500 and SLY3500 operators!For mechanical installation of the operator use the instruction included with the operator.
FEATURES Type of gate motor used Motor Voltage Controller (CB400 kit) Max. Gate weight (kg) Motor Protection Switch Thermal protection (internal) Hold to run function Automatic function IR-Sensor Radio Automatic close Flashing Light Safety edges Emergency Stop External Light switching function Traffic light with Red-Light
SLY2500 230Volt AS210B 2500kg no yes yes yes yes external yes* yes* yes* yes* yes* yes*
SLY3500 400Volt AS210B 3500kg yes no yes yes yes external yes* yes* yes* yes* yes* yes*
* requires ZM-SKS-B plug in card
IMPORTANT:
BEFORE the installation of control board make sure it is checked if your control motor requires to be set for 400Volt, 3-Phase or 230Volt, 1-Phase (X4 terminal).
A. X1: X2: X3: X4: X5:
Test button OPEN direction (S01) / Test button CLOSE direction (S02) Terminals Terminals Terminals Terminals Terminals Mains Motor / safety circuit of drive Command devices Selection 230V / 400V Limit switches
Terminals for 3-way switch Plug-in socket for ZM-SKS-B circuit card Plug-in socket for spiral cable Terminals for traffic light / yard light (only in connection with a ZM SKS B plugin circuit card) X10: Terminals for press-and-release CLOSE- OPEN X11: Not used
X6: X7: X8: X9:
Installation of control board:
The assembly instructions assume that there is no control board pre-installed. [. . . ] For relay photocell with 3-wire technology Closing direction Terminal 5: +24Volt Terminal 6: Ground Terminal 2: Signal Notice: A 4-wire photocell requires a jumper to be added 5. For relay photocell with 4-wire technology
OPENING direction Terminal 14+15: Signal Terminal 5 : + 24VDC Terminal 6 : - 24VDC
MORE OPTIONS:
·
For Chamberlain 2-wire photocells the optional 600213-2 interface box is required. Potential-free normally open contact; min. 230V AC / 4A. Contacts used once for power switching can not be subsequently used for connecting small currents. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN SLY2500
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.