User manual CHAMBERLAIN SLY3500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CHAMBERLAIN SLY3500. We hope that this CHAMBERLAIN SLY3500 user guide will be useful to you.

Lastmanuals help download the user guide CHAMBERLAIN SLY3500.


Mode d'emploi CHAMBERLAIN SLY3500
Download
Manual abstract: user guide CHAMBERLAIN SLY3500

Detailed instructions for use are in the User's Guide.

[. . . ] Attention: This product may only be installed from professional installers. Only qualified and trained electricians may connect, programme and service the controls. Qualified and trained electricians meet the following requirements: - have knowledge of the general and specific safety and accident prevention regulations, - have knowledge of the relevant electrical regulations, - are trained in the use and care of appropriate safety equipment, - are capable of recognising the dangers associated with electricity. Model Number: Controller Max. Gate weight (kg) Motor Protection Switch Hold to run function Automatic function IR-Sensor Automatic close Flashing Light Safety edges Emergency Stop Radio External Light switching function Traffic light with Red-Light Technical Data Voltage Phases Frequency Current (nominal) Power Motor Protection Switch Torque (max. ) Gear Reduction Duty Cycle Rating Temperature Range IP-Rating Gate Speed Sprocket Weight SLY3500 none 5500kg yes no no no no no no no no no no SLY3500E1 EWS2T 5500kg yes no no no no no no possible external no no SLY3500E2 CB400 3500kg yes yes yes yes yes* yes* yes* yes* external yes* yes* * requires optional ZM-SKS-B plug in card 415V 3 50Hz 1, 79A 0, 75 kW adjust to 2. 1 150Nm 1:40 60% -25/+55°C IP55 10m/min 90mm / Module 4 41kg INSTALLATION OF DRIVE The base for the drive can either be concreted or, if appropriate, made of steel. [. . . ] The bracket must be mounted with screws immediately. INITIAL OPERATION Check gate functionality manually when the drive has been disengaged. Electrical operation is only possible with a controller. Electrical connections: See electrical wiring diagram Always ensure that the mechanical and electrical safety requirements relevant to the given system are complied with. A sliding gate can also be secured by implementing on-site measures (fence, wall, etc. ). Motor Protection Switch The motor protection switch protects the motor. The switch turns the power OFF automatically in case of a motor overload. Notice: Do never turn the adjustment higher than 2. 1 MAINTENANCE WORK (monthly) The drive mechanics are generally maintenance-free. Check at regular intervals that the gate hardware and the drive are all firmly in place. · Disengage the drive and check gate functionality. Only an easy-running gate will work well with a drive. A drive is no substitute for a poorly functioning gate. · Inspect for oil leakage on gear box. · Inspect for damage to electrical wiring Electrical Installation Control Board EWS2T The gate can be moved in the hold-to run mode. Notice: A change in wiring of the control board to allow constant movement of the gate is not allowed. · See wiring diagram for electrical connection. Accessories: · 3-Button station · Emergency Stop Switch · External 2-channel radio receiver 8002E Declaration of Conformity Automatic Gate Opener Models. . . . . . . . . SLY3500, SLY3500E are in conformity to the applicable sections of Standards: EN55014 · EN61000-3 · EN60555, EN60335-1 · ETS300 683 · EN60335-1: 2002 · EN60335-2-103: 2003 · EN55014-1: 2000 + A1 + A2 · EN55014-2: 2001 · EN61000-3-2: 2000 · EN61000-3-3: 1995 + A1 · EN 301 489-3, V1. 3. 1 · EN13241-1 per the provisions & all amendments of the EU Directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2006/95/EC, 2004/108/EC, 1999/5/EG Declaration of Incorporation Automatic Gate Opener Models , when installed and maintained according to all the Manufacturer's instructions in combination with a Gate, which has also been installed and maintained according to all the Manufacturer's instructions, meets the provisions of EU Directive 89/392/EEC and all amendments. I, the undersigned, hereby declare that the equipment specified above and any accessory listed in the manual conforms to the above Directives and Standards. Harry Naumann Manager, Regulatory Affairs Chamberlain GmbH D-66793 Saarwellingen Germany February, 2008 CONTROL BOARD KIT CB400 for AC SLIDING GATE OPERATORS -Installation Instructionswww. liftmaster. de Email: info@chamberlain. de Chamberlain GmbH Alfred Nobel Strasse 4 D-66793 Saarwellingen Germany This product may only be installed from professional installers. Only qualified and trained electricians may connect, programme and service the controls. Qualified and trained electricians meet the following requirements: - have knowledge of the general and specific safety and accident prevention regulations, - have knowledge of the relevant electrical regulations, - are trained in the use and care of appropriate safety equipment, - are capable of recognising the dangers associated with electricity. Attention: Scope of these instructions: These instructions describe the installation and options for the product CB400 (control board AS210B): Some features require the optional ZM-SKS plug in logic board to work. This manual should only be used together with SLY2500 and SLY3500 operators! [. . . ] for 8. 2 kW electrical safety contact edges, terminating resistor and for dynamic optical systems Relay outputs:* Fuse protection: Consumption of the controls alone: Control voltage: Temperature range: Air humidity: Weight: Guidelines: Control inputs: if inductive loads are connected (e. g. additional relays or brakes), they must be fitted with appropriate interference suppression devices (freewheeling diodes, varistors, resistor-capacitor elements). Potential-free normally open contact; min. 230V AC / 4A. Contacts used once for power switching can not be subsequently used for connecting small currents. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN SLY3500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN SLY3500 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag