Installation and Programming Manual
The Chamberlain Group 845 Larch Ave. Elmhurst, IL 60126-1196 www. liftmaster. com
TABLE OF CONTENTS
SPECIFICATIONS
Cable Requirements Dimensions Carton Inventory
3
3 3 3
TESTING
Test the Gate/Door Relay Test the Telephone Connections
12
12 12
INSTALLATION
Mount the Back Panel Description of the Processor Board Overview of Telco Wiring Wiring the Unit With a Telco Line Wiring the Unit Without a Telco Line Wiring a Gate Operator Wiring an Auto-Call Sensor Wiring a Gate Operator and a Door Strike Lock Wiring a Gate Operator and a Maglock Wiring a Door Strike Lock Wiring a Maglock Earth Ground Rod Power Wiring Plug the Transformer into the Outlet Mount the Unit Set the Master Code
4-11
4 4 5 6 6 7 7 8 8 9 9 10 10 11 11 11
PROGRAMMING
From the TAC1 Keypad Code Setup and Code Operation From the Telephone Program a Pre-Installed Liftmaster Receiver Quick Reference
13-19
13 14 15-16 16 17-18
TAC1 MASTER CODE LIMITED WARRANTY
19 20
2
SPECIFICATIONS >> CABLE REQUIREMENTS, DIMENSIONS AND CARTON INVENTORY
CABLE REQUIREMENTS
Outdoor installations require shielded cable. Non-shielded cable can be used for indoor installations ONLY. PROCESSOR BOARD From the power transformer at 120 Vac outlet From the door strike, maglock or gate operator From the strike power supply (if needed) From the Earth ground to processor board WIRE TYPE 2 - Conductor Cable 2 - Conductor Cable 2 - Conductor Cable 12 AWG copper wire, PVC insulated or 12 AWG copper wire, uninsulated 24 AWG twisted pair telephone wire 24 AWG twisted pair telephone wire 24 AWG twisted pair telephone wire POWER WIRE TABLE DISTANCE Under 30 feet 30 - 75 feet 75 - 150 feet 150 - 250 feet 250 - 500 feet AC POWER WIRE SIZE 18 AWG 18 AWG 18 AWG 16 AWG 12 AWG RECOMMENDATIONS Shielded Only - See Power Wire Table Below See device specifications for wire size See device specifications for wire size Belden #9912
Belden #8011 Shielded - Belden #9502 Shielded - Belden #9502 Shielded - Belden #9502
Residence and Telco phone lines From the Processor Board Between Processor Boards on multiple entrance installation
NOTE: Chamberlain is not responsible for conflicts between the information listed in the above table and the requirements of local building codes. [. . . ] This will prevent two problems: · Other equipment cannot introduce spikes, noise, surges, or dips into the power circuit. · The system's operation will not be affected if any other equipment develops a short circuit across the power line. Connect the transformer into a 110 Vac outlet after all connections have been made, any other type of outlet will cause damage to the system. POWER WIRE TABLE DISTANCE Under 30 feet 30 - 75 feet 75 - 150 feet 150 - 250 feet 250 - 500 feet AC POWER WIRE SIZE 18 AWG 18 AWG 18 AWG 16 AWG 12 AWG
1 2 POWER
Refer. Bus 1, 2, 3
Air (1) Conditioner
M a in Room
Conference Rm 2, 3
Conference Room 2
Com p. Serve 2
Off ff
Conference Room 1
TAC 1
Eug. 2 Rm
Dedicated 10 Amp Minimum Circuit Breaker 12 Vac Power (included) The TAC 1 MUST be grounded. Dedicated Outlet
NOTE: Chamberlain is not responsible for conflicts between the information listed in the above table and the requirements of local building codes. The information is for suggested use only. Check local building codes before installation.
10
INSTALLATION >> PLUG THE TRANSFORMER INTO THE OUTLET, MOUNT THE UNIT AND
SET THE UNIT MASTER CODE PLUG THE TRANSFORMER INTO THE OUTLET
Plug the transformer into the 110 Vac outlet.
12 Vac Power (included)
1
2
POWER
110 Vac Outlet
1 2
POWER
Check the Power LED is illuminated.
NOTE: Once power is applied, the TAC1 will begin to click to indicate that it is powered, and is waiting to be programmed for the unit's Master Code. The Master Code is used to unlock the programming functions of the TAC1. The Master Code should not be distributed as a User Code.
MOUNT THE UNIT
Mount the unit onto the back panel. Stop and go keystrokes will result in negative tones (low single and triple fail tones). ?
ENABLE PARALLEL RELAY OUTPUT (DEFAULT) 1. Write down the Master Code and store in a secure location. ENABLE TELCO MODE Telco Mode is using the main telephone line for the unit's communications to the house or complex. ?
ENABLE INDEPENDENT RELAY OUTPUT CONTROL 1. 3 ?
ADJUST RELAY OUTPUT TIME (RELAY 1) The amount of time (in seconds) the relay remains active. Enter the Program Code: MICROPHONE SENSITIVITY Allows the resident to hear the visitor at the unit, 1 = Low, 2 = Medium and 3 = High. Enter the Volume Level: SPEAKER VOLUME Allows the visitor to hear the resident at the unit, 1 = Low, 2 = Medium and 3 = High. Example: 0000 = 0. 5 Seconds (Minimum) 0010 = 10 Seconds 8000 = 8000 Seconds (Maximum)
ADJUST RELAY OUTPUT TIME (RELAY 2) The amount of time (in seconds) the relay remains active. Default level is 0. 5 seconds.
or
2
or
3
1. [. . . ] Master Code (4 digits) + 025 + Relay Output Time (0000-8000 Seconds) NOTE: Relay output time is ALWAYS 4 digits.
DIRECT COMMANDS FROM THE TAC1 KEYPAD
KEYSTROKES User Code + 1 User Code + 2 ACTION Triggers Relay 1 Triggers Relay 2
AUDIO FEEDBACK FROM THE TAC1: 1 Low Tone = Failure 2 Tone Beep = Valid sequence 3 Tone Beep = Error or invalid sequence NOTE: Use the STAR Key "*" to cancel any input. NOTE: Keypad commands are to be entered in a single string to result in success (indicated by double high success tone). Stop and go keystrokes will result in negative tones (low single and triple fail tones).
17
PROGRAMMING >> QUICK REFERENCE
TELEPHONE PROGRAMMING
PROGRAMMING DESCRIPTION OF TASK NUMBER **01 **02 **03 **06 **07 **#8 **10 **13 **14 **15 #*16 *# Call Forwarding Number # Enable Call Forwarding Disable Call Forwarding Enable Intercom Mode Verify Call Forwarding Number (Via Caller ID) Enable Telco Mode Erase Call Forwarding Number Adjust "Pick-Up" Ring Count Enable Alternate DTMF Programming Enable Standard (Long) Ring Tone Enable Alternate (Dual) Ring Tone Disable Alternate DTMF Programming Enter Call Forwarding Telephone Number Enabled Disabled Disabled Disabled Disabled FACTORY SETTING Disabled PROGRAMMING PROCEDURE **01 **02 **03 **06 **07 **#8 **10 + Ring Count (2-5) **13 **14 **15 **16 *# + Telephone Number (Up to 14 digits) + #
DIRECT COMMANDS FROM THE LOCAL TELEPHONE
PROGRAMMING DESCRIPTION OF TASK NUMBER *5 *9 **04 **05 **11 **12 Triggers Relay 2 Triggers Relay 1 Enable Party (Latched) Mode Relay 1 Disable Party (Latched) Mode Relay 1 Enable "Do Not Disturb" Mode Disable "Do Not Disturb" Mode Disabled **11 **12 FACTORY SETTING PROGRAMMING PROCEDURE *5 *9 **04
DIRECT COMMANDS FROM THE FORWARDED TELEPHONE
PROGRAMMING DESCRIPTION OF TASK NUMBER 0 *5 *9 Accepts Call From The Unit Triggers Relay 2 Triggers Relay 1 FACTORY SETTING PROGRAMMING PROCEDURE 0 *5 *9
NOTE: Use the STAR Key "*" to cancel any input. NOTE: Keypad commands are to be entered in a single string to result in success (indicated by double high success tone). [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN TAC1
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.