User manual CHANEY INSTRUMENTS INDOOR HUMIDITY MONITOR MODEL 00613

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CHANEY INSTRUMENTS INDOOR HUMIDITY MONITOR MODEL 00613. We hope that this CHANEY INSTRUMENTS INDOOR HUMIDITY MONITOR MODEL 00613 user guide will be useful to you.

Lastmanuals help download the user guide CHANEY INSTRUMENTS INDOOR HUMIDITY MONITOR MODEL 00613.


Mode d'emploi CHANEY INSTRUMENTS INDOOR HUMIDITY MONITOR MODEL 00613
Download
Manual abstract: user guide CHANEY INSTRUMENTS INDOOR HUMIDITY MONITOR MODEL 00613

Detailed instructions for use are in the User's Guide.

[. . . ] Any product which, under normal use and service, is proven to breach the warranty contained herein within ONE YEAR from date of sale will, upon examination by Chaney, and at its sole option, be repaired or replaced by Chaney. In all cases, transportation costs and charges for returned goods shall be paid for by the purchaser. Chaney hereby disclaims all responsibility for such transportation costs and charges. This warranty will not be breached, and Chaney will give no credit for products it manufactures which shall have received normal wear and tear, been damaged, tampered, abused, improperly installed, damaged in shipping, or repaired or altered by others than authorized representatives of Chaney. [. . . ] This sensor should be mounted high enough to accurately record and transmit wind information. Powered by 2 "AA" batteries. 2. Install 2 "AA" batteries into the battery compartment. Replace the compartment cover and replace the solar shield. REMOVE BATTERY DOOR -2- -3- Wireless Wind Sensor INSTALL BATTERIES: 1. Install 2 "AA" batteries into the battery compartment. Replace the battery compartment cover and replace and rotate the bottom cone section until it is securely tightened. SECTION 2 · SETUP Main Unit Startup INSTALL BATTERY After batteries are installed in both wireless sensors and the main unit is powered up, the main unit will search for the wireless sensor signals. After the sensors signals are received, the main unit will search for the atomic clock signal. After the atomic clock signal is received, the time and date will be maintained automatically. This may take up to 24 hours and may not occur at all depending on your geographical location and your physical surroundings. See "troubleshooting" for atomic clock tips. INSTALL BATTERY REMOVE SLIDING BATTERY COMPARTMENT COVER You may "force" the unit to search for the atomic clock at any time by pressing and holding the "-" button on the back of the main unit for 3 seconds. Time & Date Setup It is recommended that the time and date be manually set initially to ensure that they are accurate until the atomic clock signal is captured. To enter into SET MODE, press and hold the "SET" button for 3 seconds. To help ensure an accurate indoor temperature measurement, be sure to place the main unit out of direct sunlight, and away from any heat sources or vents in your home. There are 2 placement options for the main unit. You may hang the main unit on a wall using the integrated hang hole on the back. Alternatively, you may place the main unit on a table top or other flat surface utilizing the removable main unit display stand. PLACEMENT 1. Attach to a solid vertical OR horizontal surface out of direct sunlight for maximum performance. Attach the mounting bracket utilizing the included screws and wall anchors (if applicable). Depending on the mounting surface, other steps may need to be taken to ensure the sensor is mounted securely. Attach the temperature & humidity sensor to the mounting bracket by simply sliding into the bracket. HORIZONTAL SURFACE Placement of Sensors The wireless sensors MUST BE PLACED OUTDOORS to observe outdoor weather conditions and relay them to the main unit display. The wireless sensors must be placed less than 100 feet from the main unit. -6- -7- SECTION 4 · OPERATION A DAILY MINIMUM/MAXIMUM TEMPERATURE MEMORY DISPLAY: Press the MIN/MAX button once to view the MINIMUM recorded values for temperature, humidity and wind speed. Press the "MIN/MAX" button again to view the MAXIMUM recorded values for temperature, humidity and wind speed. While viewing the MINIMUM or MAXIMUM, press and hold the "MIN/MAX" button for 2 seconds to clear the currently viewed recorded values. WIND GUST DST OFF ON H AM PM E TIMEZONE PST MST CST EST N mph kph knots A MAX MIN INDOOR E C NW NE FUTURE FORECAST W SW SE B PRESSURE HISTORY: Also available to you is the option to go back through the last 12 hours of pressure readings. [. . . ] It is important that the atomic clock sensor (located in the wireless temperature/humidity sensor) is located in an area clear of any large stone or metallic surfaces. Make sure the main unit is placed at least 3 feet from other electronic appliances and devices that may interfere with the wireless communication (such as TV's, microwaves, computers etc). Large metallic surfaces will also interfere with the atomic clock signal. If wireless reception is bad (no bars), see "Bad Reception" section above. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHANEY INSTRUMENTS INDOOR HUMIDITY MONITOR MODEL 00613

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CHANEY INSTRUMENTS INDOOR HUMIDITY MONITOR MODEL 00613 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag