User manual CHICAGO 66835

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CHICAGO 66835. We hope that this CHICAGO 66835 user guide will be useful to you.

Lastmanuals help download the user guide CHICAGO 66835.


Mode d'emploi CHICAGO 66835
Download
Manual abstract: user guide CHICAGO 66835

Detailed instructions for use are in the User's Guide.

[. . . ] 800/1000 watt pure sine wave pOwer inverter with GFCi 66835 set up and OperatinG instruCtiOns distributed exclusively by Harbor Freight tools®. 3491 Mission Oaks Blvd. , Camarillo, CA 93011 visit our website at: http://www. harborfreight. com read this material before using this product. Failure to do so can result in serious injury. save tHis manual. Copyright© 2009 by Harbor Freight Tools®. [. . . ] the warnings, precautions, and instructions discussed in this instruction sheet cannot cover all possible conditions and situations that may occur. it must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator. Features - Overload Shutoff @ 15VDC - Low Voltage Alarm @ 10. 6VDC - Low Voltage Shutoff @ 10VDC -Cooling Fans x 2 unpaCKinG When unpacking, make sure that the item is intact and undamaged. If any parts are missing or broken, please call Harbor Freight Tools at 1-800-444-3353 as soon as possible. COmpOnents and COntrOls speCiFiCatiOns Continuous Power 800 Watts Peak Power Input Voltage Output Voltage Fuse Indicators Switch Output Wave Form Cables (not included) Outlets 1000 Watts 12 Volts Nominal DC (10-15VDC possible) 120V/60Hz 40A x 4 (Blade Type) Green LED = power on Red LED = error (fault) Rocker type. ON/OFF Pure Sine Wave #4AWG or larger heavy duty input 2 - 120V grounded AC with Ground Fault Circuit Interupt Fan (8) Grounding Negative Positive Terminal Terminal Terminal (4) (6) (5) GFCI Test LED GFCI Reset Switch (15) Outlets (16) Power Over-load Over-temp. LED LED LED Figure 1 SKU 66835 For technical questions, please call 1-800-444-3353. Page 4 impOrtant saFetY inFOrmatiOn use caution when opening the plastic case; risk of electric shock. prevent body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerator enclosures during installation. all connections must be done with the inverter's power switch off. Connect all wires securely and cover the connections with insulating rubber boots (not included). store metal objects away from the inverter. 5. This product is not a toy. Do not allow children to play with or near this item. Inspect before every use; do not use if parts are loose or damaged. These carry important safety information. If unreadable or missing, contact Harbor Freight Tools for a replacement. 6. 8. OperatinG instruCtiOns read the entire impOrtant saFetY inFOrmatiOn section at the beginning of this manual including all text under subheadings therein before set up or use of this product. Caution: This inverter must only be connected to batteries with a nominal output voltage of 12 volts. Lower voltage will not operate the inverter properly, and more voltage could damage the inverter or the device being powered. If more than one 12 volt battery is to be used, the batteries must be connected in a parallel circuit; batteries connected in a series circuit will produce too much voltage. Place the Power Inverter on a flat surface. Make sure it has adequate ventilation and is not in direct sunlight. Locate the Inverter close enough to the battery so that the cables can easily reach between the Inverter and the battery. Position the Inverter so that the Outlets are easily and safely accessible. Make sure the Inverter is in its OFF position. [. . . ] Reduce the number of watts you are powering. Also, keep input voltage above 11 volts to maintain a constant flow of power. If you are not getting any power output, turn the power switch Off and On again, until the green power light comes on. Your devices may draw too much power to operate them. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHICAGO 66835

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CHICAGO 66835 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag